YY/T 1976-2025Traditional Chinese medical device - Glass cupping device (English PDF)
中医器械 玻璃拔罐器
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1976-2025 in 30 minutes.
Issued by
National Medical Products Administration
Level / Type
National · Recommended
Issue date
June 18, 2025
Implementation date
July 1, 2026
Scope
YY/T 1976-2025 is the English-translated version of 中医器械 玻璃拔罐器.
YY/T 1976-2025 — This document specifies the specifications and requirements for glass cupping sets and describes the corresponding test methods. This document applies to glass cupping devices.
This document does not apply to manual or electric negative pressure cupping devices.
Found what you need?
Document preview — YY/T 1976-2025
National Standard of the People's Republic of China
- ICS
- 11.040.99
- Classification
- C 42
Issued by: National Medical Products Administration
Contents
- Preface
- 1 Scope
- 2 Normative References
- 3 Terms and Definitions
- 4 Specifications
- 5 Requirements
- 6 Test Methods
- Appendix A (Informative) Negative Pressure Testing Apparatus
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents".
Drafting.
This document is modified to adopt ISO 22213:2020 "Glass cupping devices for traditional Chinese medicine".
Compared with ISO 22213:2020, this document has undergone the following structural adjustments.
---Added sections 5.1 and 5.2, corresponding to sections 5.2 and 5.3 in ISO 22213:2020.Section 5.3 corresponds to sections 4.3 and 5.6 in ISO 22213:2020.
This corresponds to section 5.1 of ISO 22213:2020;
---A new chapter, Test Methods, has been added, with 6.4.1 and 6.4.2 corresponding to 5.4.3 in ISO 22213:2020.
The technical differences between this document and ISO 22213:2020, and the reasons therefor, are as follows.
---ISO 10993-1 (see 5.6, 6.6) has been replaced with the normatively referenced GB/T 16886.1 to adapt to my country's technical conditions.
High operability;
---ISO 3585 (see 5.3, 6.3) has been replaced with the normatively referenced GB/T 34843 to adapt to my country's technical conditions and improve reliability.
Operability;
---ISO 17664 (see 5.5, 6.5) has been replaced with the normatively referenced YY/T 0802 to adapt to my country's technical conditions and improve reliability.
Operability;
---ISO 10993-4, ISO 10993-10, ISO 10993-18, ISO/T S10993-19, and ISO 15223-1 have been removed to suit my needs.
The actual situation in the country;
---The term "cupping" has been removed from the terms and definitions; it does not need to be defined in this document.
---The terminology and description of instantaneous pressure in "resistance to negative pressure" have been changed to instantaneous negative pressure (see 3.3, 5.4.1), and the definition has been revised, resulting in a more accurate description.
For accuracy;
---The recommended models by volume have been removed, replaced with examples of commonly used models named alphabetically, and the phrase "can also be specified by the manufacturer" has been added.
The designation (see 4.2.1) ensures that the tank number matches the internal volume, avoiding ambiguity and adapting to my country's actual situation.
---The requirement for content volume size has been removed, replaced with a common size example, and "can also be specified by the manufacturer" (see 4.2.2) has been added, allowing...
The difference was changed to ±10%, and the internal volume of the XS size was changed to 80 mL (see Table 1) to adapt to the actual situation in my country;
---The tank glass wall thickness value has been removed to better suit my country's specific circumstances and improve operability;
---Dimensional requirements and test methods have been added (see 5.1, 6.1) to improve the standardization of glass cupping sets;
---Added requirements for the appearance of glass cupping sets with other internal volumes, which are now specified by the manufacturer (see 5.2), to adapt to the actual situation in our country.
Condition;
---The instantaneous pressure during negative pressure maintenance is changed to the initial negative pressure value (see 5.4.2) to improve operability;
---The packaging has been removed (see Chapter 6 of ISO 22213:2020) to suit my country's specific circumstances;
---The symbol has been removed (see Chapter 7 of ISO 22213:2020) to adapt to the actual situation in my country;
---The test methods for resistance to negative pressure and maintenance of negative pressure in Appendix A have been moved to Chapter 6 (see 6.4.1, 6.4.2) to improve operability.
Acting.
The following editorial changes have been made to this document.
---The term "Traditional Chinese Medicine" in the standard name has been changed to "Traditional Chinese Medicine Instruments";
---The phrases "glass cupping devices operate by generating negative pressure through a heat source placed inside the cup" and "single and repeated" have been removed from the scope.
The phrase "use" should be changed from "vacuum cupping devices as defined in ISO 19611" to "manual or electric negative pressure cupping devices".
---Note added to definition 3.2;
---The content of Figure A.1 has been changed;
---References have been removed.
Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.
This document was proposed by the National Medical Products Administration.
This document is under the jurisdiction of the Standardization Technical Unit for Traditional Chinese Medicine Instruments (SMD/T U008).
1 Scope
This document specifies the specifications and requirements for glass cupping sets and describes the corresponding test methods.
This document applies to glass cupping devices.
This document does not apply to manual or electric negative pressure cupping devices.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.
For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.
This document.
GB/T 16886.1 Biological evaluation of medical devices – Part 1: Evaluation and testing in the risk management process (GB/T 16886.1-2022, ISO 10993-1:2018, IDT) GB/T 348433.3 Properties of borosilicate glass (GB/T 34843-2017, ISO 3585:1998, MOD) YY/T 0802 Handling of Medical Devices - Information provided by medical device manufacturers (YY/T 0802-2020, ISO 17664.
2017, MOD)
3 Terms and Definitions
The following terms and definitions apply to this document.
glass cupping device Glassware used in cupping therapy.
negative pressure
Gas pressure below ambient atmospheric pressure.
Note. The negative pressure value in this document represents the difference between the air pressure inside the glass cupping device and the atmospheric pressure.
The short-term negative pressure generated inside the glass cupping device.
4 Specifications
4.1 Structural Form
The typical shape and structure of a glass cupping device is shown in Figure 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 16886.1Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
- GB/T 16886.1-2022Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
- GB/T 34843-2017Borosilicate glass 3.3 -- Properties
- YY/T 0802Processing of medical devices—Information to be provided by the medical device manufacturer
- YY/T 0802-2020Processing of medical devices—Information to be provided by the medical device manufacturer
ISO 10993 · GB/T 348433.3 · ISO 3585 · ISO 17664
How to Download YY/T 1976-2025
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16886.1-2022 — Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
GB/T 16886.10-2024 — Biological evaluation of medical devices - Part 10: Tests for skin sensitization
GB/T 16886.11-2021 — Biological evaluation of medical devices - Part 11: Tests for systemic toxicity