YY/T 1957-2025Vacuum washer-disinfectors (English PDF)
负压清洗消毒器
Open the YY/T 1957-2025 preview as PDF
This is a limited preview
Buy now to download the full PDF (15 pages)
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
February 26, 2025
Implementation date
September 1, 2026
Scope
YY/T 1957-2025 is the English-translated version of 负压清洗消毒器.
YY/T 1957 is the product standard for the negative pressure washer-disinfector used in hospital sterile services. It specifies the performance requirements for negative pressure cleaning and disinfection equipment and describes the corresponding test methods, applying to washer-disinfectors that operate under negative pressure. Drawing a vacuum during the cycle helps liquid reach the inside of narrow lumens, which is precisely where conventional washers fail and where the reprocessing of endoscopes and cannulated instruments succeeds or does not. The standard's job is to make that cleaning performance measurable rather than assumed. It takes effect on 1 September 2026. For a manufacturer or an importer of washer-disinfectors for the Chinese market, this is the standard the performance testing follows.
Document preview — YY/T 1957-2025
National Standard of the People's Republic of China
- ICS
- 11.080.10
- Classification
- C47
Issued by: National Medical Products Administration
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and Definitions1
- 4 Performance requirements2
- 10 Reference11
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part
1.Structure and drafting rules for standardization documents" Drafting. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document is proposed by the State Food and Drug Administration. This document is under the jurisdiction of the National Technical Committee for Standardization of Disinfection Technology and Equipment (SAC/TC200). This document was drafted by: Shandong Xinhua Medical Device Co., Ltd., Guangdong Medical Device Quality Supervision and Inspection Institute, Guangzhou Jihao Medical Medical Technology Co., Ltd., Beijing Baixiang New Technology Co., Ltd., and Peking Union Medical College Hospital, Chinese Academy of Medical Sciences. The main drafters of this document. Zhang Longlong, Liao Huier, Li Yadong, Tang Xiaowei, Sun Mingqiang, Zhang Qing, Zhou Yuxin, Li Lin, Xia Yi. Negative pressure cleaning disinfector
1 Scope
YY/T 1957 is the product standard for the negative pressure washer-disinfector used in hospital sterile services. It specifies the performance requirements for negative pressure cleaning and disinfection equipment and describes the corresponding test methods, applying to washer-disinfectors that operate under negative pressure. Drawing a vacuum during the cycle helps liquid reach the inside of narrow lumens, which is precisely where conventional washers fail and where the reprocessing of endoscopes and cannulated instruments succeeds or does not. The standard's job is to make that cleaning performance measurable rather than assumed. It takes effect on 1 September 2026. For a manufacturer or an importer of washer-disinfectors for the Chinese market, this is the standard the performance testing follows.
This document specifies the performance requirements for negative pressure washer-disinfectors and describes the corresponding test methods. This document is applicable to cleaning and disinfection equipment with negative pressure cleaning function and in compliance with the applicable clauses in YY/T 0734.1 and the requirements of the corresponding special standards. Poison weapon. This document does not apply to washer-disinfectors that do not have negative pressure cleaning function.
2 Normative references
The contents of the following documents constitute essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document.
GB 8599-2023 Technical requirements for large pressure steam sterilizers
YY/T 0734.1-2018 Washer-disinfector Part
3 Terms and definitions
The terms and definitions defined in YY/T 0734.1-2018 and the following apply to this document.
3.1 A0 value The equivalent time measured in seconds during moist heat disinfection at 80°C is taken as 10°C. [Source: YY/T 0734.1-2018, 3.1]
3.2 Bubble Generator A device that introduces external filtered air into the cavity and evenly generates bubbles in the water during the liquid phase pulsating cleaning process.
3.3 Bubble washing The cleaning method utilizes the pressure difference between the inside and outside of the cavity and generates bubbles through a bubble generating device to achieve load cleaning.
3.4 Chamber Negative pressure washer-disinfector A device that handles loads and withstands negative pressure environments.
3.5 The water in the cavity is pumped to a boiling state under negative pressure at a set temperature, and the filtered air from the outside is returned to the liquid surface through the gas phase. The empty pipe is introduced into the cavity and quickly re-pressurized, so that the water inside the cavity flows back and forth many times to achieve the purpose of stripping pollutants. Cleaning method.
3.6 Hot air drying hotairdrying A method that uses flowing hot air to increase the surface temperature of the load and remove residual moisture.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
How to Buy YY/T 1957-2025
- 1Add to cart. Click the "Buy YY/T 1957-2025" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 8599-2023 — Technical requirements for large steam sterilizers
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0492-2026 — Implantable leads
Secure payment via Stripe
Payments accepted
YY/T 1957-2025
$230.00