YY/T 1869-2023Detector array measurement system - Performance characteristics and test methods (English PDF)
探测器阵列剂量测量系统 性能和试验方法
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1869-2023 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
January 13, 2023
Implementation date
July 15, 2024
Scope
YY/T 1869-2023 is the English-translated version of 探测器阵列剂量测量系统 性能和试验方法.
YY/T 1869 covers the detector array dose measurement systems used in radiotherapy quality assurance, the panels of detectors that verify a treatment plan actually delivers the dose distribution it was designed to.
It specifies the performance characteristics such a system must have and the test methods that establish them, covering dose response and linearity, spatial resolution, reproducibility, angular dependence and the corrections applied to the raw reading.
These systems sit between the planning computer and the patient: if the array itself is not characterised, the verification it performs proves nothing. Intensity-modulated and volumetric-arc treatment cannot be delivered safely without patient-specific quality assurance of this kind.
For a manufacturer of dosimetry equipment this is the standard a Chinese registration is assessed against.
Found what you need?
Document preview — YY/T 1869-2023
National Standard of the People's Republic of China
- ICS
- 11.040.50
Issued by: National Medical Products Administration
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and Definitions1
- 4 Requirements1
- 4.1 Random file1
- 4.2 Detector Array2
- 4.4 Instruction2
- 4.5 Software functions3
- 5 Test method3
- 5.1 Random file3
- 5.2 Detector Array3
- 5.4 Indication4
- 5.5 Software functions4
- 4 Reference5
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part
1.Structure and Drafting Rules for Standardization Documents" drafting. Please note that some contents of this document may refer to patents. The issuing agency of this document assumes no responsibility for identifying patents. This document is proposed by the State Drug Administration. This document is prepared by the National Medical Electrical Appliances Standardization Technical Committee Radiotherapy, Nuclear Medicine and Radiation Dosimetry Equipment Standardization Sub-Technical Committee Meeting (SAC/TC10/SC3) centralized. This document was drafted by: Beijing Institute of Medical Device Testing, Peking University Third Hospital, Pedway Radiation Measuring Instruments (Beijing) Co., Ltd. Co., Ltd., Yibia (Beijing) Particle Accelerator Technology Co., Ltd., Varian Medical Devices Trading (Beijing) Co., Ltd. The main drafters of this document. Fu Guotao, Yang Ruijie, Jiao Chunying, Liu Di, Xu Lin, Wang Shun, Zhang Xin. Performance and Test Method of Detector Array Dosimetry System
1 Scope
YY/T 1869 covers the detector array dose measurement systems used in radiotherapy quality assurance, the panels of detectors that verify a treatment plan actually delivers the dose distribution it was designed to. It specifies the performance characteristics such a system must have and the test methods that establish them, covering dose response and linearity, spatial resolution, reproducibility, angular dependence and the corrections applied to the raw reading. These systems sit between the planning computer and the patient: if the array itself is not characterised, the verification it performs proves nothing. Intensity-modulated and volumetric-arc treatment cannot be delivered safely without patient-specific quality assurance of this kind. For a manufacturer of dosimetry equipment this is the standard a Chinese registration is assessed against.
This document specifies the performance and test methods of the detector array dosimetry system (hereinafter referred to as the array system). This document is applicable to the detector array dosimetry system, including the detector array and supporting measurement software and result analysis software.
2 Normative references
The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.
GB 9706.201 Medical electrical equipment Part 2-
3 Terms and Definitions
The following terms and definitions defined in GB 15213-2016, GB 9706.201 and GB/T 17857-1999 apply to this document.
3.1 An array composed of multiple detectors, and a dosimetry system composed of supporting measurement software and result analysis software are used to measure The dose distribution after the radiation therapy equipment is projected, and compared with the dose distribution calculated by the treatment planning system, and the radiation dose is determined according to the specified standards. Whether the dose distribution of the treatment equipment meets the requirements after irradiation.
4 Requirements
4.1 Random files Random documents should contain at least the following.
a) detector type;
b) Dimensions and sensitive volume of a single detector;
c) The number and spatial distribution of detectors;
d) the effective detection range of the detector array;
e) The actual thickness, composition, material, density and water equivalent thickness of the detector array;
f) Sensitivity of the detector array and its influencing factors;
g) Types of measurement rays, energy response ranges, dose ranges and dose rate ranges;
h) The minimum time sampling interval and charge collection time for measurements;
i) energy dependence of the detector array;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 9706.201Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV
- GB 15213-2016Medical electron accelerators-Functional performance characteristics and test methods
- GB/T 17857-1999Medical radiology. Terminology (Equipment for radiotherapy, nuclear medicine and radiation dosimetry)
Similar standards
HJ 1198|GJB 1763
How to Download YY/T 1869-2023
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 15213-2016 — Medical electron accelerators-Functional performance characteristics and test methods
GB 9706.201-2020 — Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV
GB/T 17857-1999 — Medical radiology. Terminology (Equipment for radiotherapy, nuclear medicine and radiation dosimetry)