YY/T 1789.2-2021In vitro diagnostic test systems-Performance evaluation method - Part 2: Trueness (English PDF)
体外诊断检验系统 性能评价方法 第2部分:正确度
This is a limited preview
Buy now to download the full PDF (25 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1789.2-2021 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
December 6, 2021
Implementation date
May 1, 2023
Scope
YY/T 1789.2-2021 is the English-translated version of 体外诊断检验系统 性能评价方法 第2部分:正确度.
YY/T 1789.2-2021 is the Chinese pharmaceutical industry standard that gives the method by which a manufacturer evaluates the trueness of an in vitro diagnostic test system.
It is the second part of the YY/T 1789 series and sets out how bias is estimated: the reference materials or comparison methods used, the samples and the number of measurements, the calculation of the bias and its uncertainty, and the way the result is judged.
It applies to quantitative systems, and not to those whose result is nominal or ordinal. Issued on 6 December 2021, it has applied since 1 May 2023.
Found what you need?
Document preview — YY/T 1789.2-2021
National Standard of the People's Republic of China
- Classification
- C 30
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 General
- 4.1 General Requirements
- 4.2 Correctness evaluation method
- 4.3 Products to be evaluated
- 4.4 Test Notes
- 4.5 Data Analysis
- 5 Evaluation of the correctness of the use of reference substances
- 5.1 Reference material requirements
- 5.2 Test time and number of tests
- 5.3 Data Analysis
- 5.3.1 Bias Estimation
- 5.3.2 Calculating confidence intervals
- 5.3.3 Example
- 6 Evaluation of correctness using patient samples
- 6.1 Sample Requirements
- 6.2 Choice of Comparison Method
- 6.3 Test time and number of tests
- 6.4 Data Analysis
- 6.4.1 Scatter or Deviation Plot
- 6.4.2 Outlier Test
- 6.4.3 Preliminary estimates of bias
- 6.4.4 Regression Analysis
- 6.4.5 Bias at the medical decision level
- 6.4.6 Data Analysis Example
- 7 Recovery test
- 7.1 Applicable conditions
- 7.2 Test method
- 7.3 Data Analysis
- Appendix A (Informative Appendix) Example of Data Analysis for Correctness Evaluation Using Reference Substances
- Appendix B (Informative) Example of Data Analysis for Correctness Assessment Using Patient Samples
- Reference
Foreword
YY/T 1789 "In Vitro Diagnostic Test System Performance Evaluation Method", consists of the following parts.
--- In vitro diagnostic test system performance evaluation method Part 1. Precision;
--- In vitro diagnostic test system performance evaluation method Part 2. Accuracy;
--- In vitro diagnostic test system performance evaluation method Part 3. detection limit and quantification limit;
--- In vitro diagnostic test system performance evaluation method Part 4. Linear interval and reportable interval;
--- In vitro diagnostic test system performance evaluation method Part 5. Analysis specificity;
--- In vitro diagnostic testing system performance evaluation method Part 6. Precision, diagnostic sensitivity and specificity of qualitative reagents. This part is Part 2 of YY/T 1789.
This section is drafted in accordance with the rules given in GB/T 1.1-2009.
Introduction
In the performance evaluation of in vitro diagnostic medical device products, in vitro diagnostic instruments, reagents, calibrators, etc.
Therefore, this series of standards adopts the concept of system to describe the performance of the measurement system composed of instruments, reagents, calibrators, etc.
Evaluation of analytical performance refers to an estimate of the reliability of a measurement system to detect patient samples. Analytical performance of in vitro diagnostic test systems Including precision, correctness, accuracy, detection limit and quantification limit, linear interval and reportable interval, analytical specificity, etc.
Measurement correctness is a performance characteristic that evaluates systematic measurement error in a series of measurements of a homogeneous sample. Correctness is a qualitative notion, but measurement bias can be assessed. Assessment of bias requires an appropriate reference substance or reference measurement procedure that can be used to determine the value of the reference quantity being measured. sequence. Correctness is to be distinguished from "accuracy". Accuracy is the difference between a measured quantity and the true quantity being measured.
The error includes the systematic measurement error component estimated by the measurement bias and the random measurement error component estimated by the standard deviation, and the accuracy is the correctness and precision. combination of densities.
In general, the accuracy evaluation is carried out only after the precision evaluation of the measurement system and the requirements are met. This section provides three positive Accuracy evaluation methods, the first method is to analyze an appropriate reference material with the value of the reference quantity to be measured, and the second method is to use patient samples for The third method is to use the recovery test. Evaluate the correctness and estimate the bias, the purpose of which is to know the magnitude of the bias. small and correct as needed.
1 Scope
This part of YY/T 1789 specifies the method for evaluating the correctness performance of in vitro diagnostic test systems.
This section applies to the manufacturer's evaluation of the correctness of in vitro diagnostic test systems for quantitative testing.
This section does not apply to in vitro diagnostic test systems in which results are reported as nominal and ordinal scales, such as for blood cell identification, microbiological Characterization of the in vitro diagnostic test system for genotyping, nucleic acid sequence identification, urine particle identification, and results reported as negative, positive, or 1, 2, and 3 can evaluate. This section also does not apply to qualitative in vitro diagnostic test systems (such as enzyme-linked immunosorbent assays) that are based on quantitative measurements and judge the results by thresholds.
The performance evaluation of the pathogenic microorganism antigen or antibody detection kit by immunosorbent method.
This section does not apply to medical laboratory accuracy performance verification, nor does it apply to product type inspection.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.
YY/T 1441 General requirements for performance evaluation of in vitro diagnostic medical devices
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1 Measurementsbias
bias An estimate of the systematic measurement error.
Note 1. Bias is inversely related to accuracy.
Note 2. The estimate of bias is the mean of a series of measurements minus the reference value. [GB/T 29791.1-2013, Definition A:3.25]
3.2 Measurementtrueness
trueness The degree of agreement between the mean value of an infinite number of repeated measurements and a reference value.
Note 1 to entry. Measurement accuracy is not a quantity and therefore cannot be expressed numerically. A measure of the degree of conformity is given in GB/T 6379.3.
Note 2. The measurement accuracy is inversely related to the systematic measurement error, but not to the random measurement error.
Note 3. The term measurement accuracy should not be used to measure correctness, and vice versa. [GB/T 29791.1-2013, Definition A:3.34]
3.3 Referencemeasurementprocedure
Accepted as a measurement procedure that provides measurement results suitable for its intended use including the evaluation of other methods of measuring the same quantity
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 1789.2-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 1441-2016 — General requirements of performance evaluation of in vitro diagnostic medical devices