YY/T 1770.1-2021Test method for thrombogenicity study - Part 1: Thrombogenicity study in dogs in vivo (English PDF)

医疗器械血栓形成试验 第1部分:犬体内血栓形成试验

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1770.1-2021 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

March 9, 2021

Implementation date

April 1, 2022

Scope

YY/T 1770.1-2021 is the English-translated version of 医疗器械血栓形成试验 第1部分:犬体内血栓形成试验.

YY/T 1770.1-2021 is the Chinese pharmaceutical industry standard that gives the in vivo thrombogenicity test in the dog, used in evaluating the blood compatibility of a medical device or material.

It is the first part of the YY/T 1770 series and sets out the animal model and its preparation, the implantation or insertion of the test and control articles, the duration of contact with blood, the anticoagulation regimen, and the examination that follows, in which thrombus is graded macroscopically and histologically.

It is used to judge whether a device or material causes thrombus to form in the body. Issued on 9 March 2021, it has applied since 1 April 2022.

Found what you need?

Document preview — YY/T 1770.1-2021

National Standard of the People's Republic of China

Classification
C 30

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Test principle
  • 5 Experimental animals
  • 6 Main instruments and test equipment

Foreword

YY/T 1770 "Medical Device Thrombosis Test" is divided into the following parts.

---Part 1: Thrombosis test in dogs;

---Part 2: In vitro thrombosis test; ... This part is part 1 of YY/T 1770.

This section was drafted in accordance with the rules given in GB/T 1.1-2009.

Introduction

The evaluation of thrombosis of medical devices can be performed in vivo, semi-in vivo and in vitro tests. Vascular patch, intravascular catheter, etc. and circulation When evaluating the blood compatibility of medical devices in contact with blood, it is necessary to evaluate the thrombosis in the body. YY/T 1770 This part is the specific test method for thrombosis test in dogs, which can be used as GB/T 16886.4 Chinese medical device/material thrombosis test Supplement.

1 Scope

This part of YY/T 1770 specifies that dogs should be used for in vivo thrombosis tests when evaluating the blood compatibility of medical devices/materials. Empirical method.

This section is suitable for evaluating whether medical devices/materials cause thrombosis in the body.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 16886.1 Biological Evaluation of Medical Devices Part 1: Evaluation and Testing in the Process of Risk Management

GB/T 16886.4 Biological Evaluation of Medical Devices Part 4: Test Selection for Interaction with Blood

3 Terms and definitions

The terms and definitions defined in GB/T 16886.1 and GB/T 16886.4 apply to this document.

4 Test principle

When medical devices/materials come into contact with human blood, the surface of the material may cause plasma proteins (such as albumin and fibrinogen, etc.) to adhere and adhere.

The protein layer will activate the coagulation pathway and cause the adhesion of platelets, forming fibrin and platelet thrombus, respectively, and the two will promote each other.

Finally, a thrombus is formed. Therefore, the medical device/material is implanted in the body through appropriate procedures, and after a certain period of time, observe the device/material table The thrombosis of the surface, implantation site, and distal organs can comprehensively reflect the adhesion of medical devices/materials to proteins in the blood, and activate the blood clotting system.

The path and the conditions that cause platelet adhesion, so as to determine whether the medical device/material has the effect of inducing thrombosis or anti-thrombosis.

5 Experimental animals

The animal species selected in this experiment is dog, and Beagle is the preferred strain, and there is no restriction on male and female (if female animals are used, they should be non-pregnant). Push At least 2 experimental animals are recommended. It is advisable to select suitable experimental animals according to the size of the test samples. The general principle is to choose larger animals as much as possible.

In order to reduce the test error caused by the mismatch between the animal blood vessel and the test sample. All animal testing should be in line with the welfare of laboratory animals Tests are conducted in regulated laboratories.

Note. For intravascular implantation, it is recommended that the cross-sectional area of the implant occupies less than 50% of the vascular cavity. According to the sample size, animal anatomy characteristics, select other bodies The suitability of larger animals is explained.

6 Main instruments and test equipment

6.1 Electronic balance.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

Referenced standards

How to Download YY/T 1770.1-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1770.1-2021

$135.00