YY/T 1768.1-2021Needle-based injection systems for medical use - Requirements and test methods - Part 1: Needle-based injection systems (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (57 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1768.1-2021 in 30 minutes.

Issued by

National Medical Products Administration

Level / Type

National · Recommended

Issue date

March 9, 2021

Implementation date

April 1, 2022

Scope

YY/T 1768.1-2021 (Needle-based injection systems for medical use - Requirements and test methods - Part 1: Needle-based injection systems) is available as an English-translated PDF.

YY/T 1768.1-2021 — This Part of YY/T 1768 specifies the requirements and test methods for needle-based injection systems. This Part applies to needle-based injection systems intended for use with needles and containers, such as pen injectors.

The containers described in this Part include single-dose, multi-dose syringe systems and cartridge systems filled by the manufacturer or end user. This Part does not apply to needleless syringes.

This Part does not address requirements and related methods for filling containers and appliances by the end user.

Found what you need?

Document preview — YY/T 1768.1-2021

National Standard of the People's Republic of China

ICS
11.040.20
Classification
C 31

Issued by: National Medical Products Administration

Contents

  • Foreword...4
  • Introduction...5
  • 1 Scope...6
  • 2 Normative references...6
  • 3 Terms and definitions, symbols and abbreviations...7
  • 3.1 Terms and definitions...7
  • 3.2 Symbols and abbreviations...9
  • 4 Requirements...11
  • 4.1 General...11
  • 4.2 System classification...11
  • 4.3 Risk analysis requirements...12
  • 4.4 Measurement uncertainty and specification compliance...12
  • 5 General design requirements...12
  • 6 Reliability requirements...14
  • 6.1 General...14
  • 6.2 Cool, standard, warm atmospheres...18
  • 6.3 Final dose accuracy (for systems classified as A and C only)...18
  • 6.4 Life cycle test (only for systems classified as A and B) - Pretreatment...19
  • 6.5 Free fall test...19
  • 6.6 Dry heat and frozen storage tests - Pretreatment...19
  • 6.7 Damp heat test (for systems classified as A and B only) - Pretreatment...20
  • 6.8 Circulation test (only for systems classified as A and B) - Pretreatment...20
  • 6.9 Vibration Test – Pretreatment...20
  • 6.10 Electromagnetic compatibility (EMC)...20
  • 7 Information provided by manufacturer...22
  • 7.1 General...22
  • 7.2 Marking...22
  • 7.3 Instructions for use...23
  • Annex A (normative) Test instruments...26
  • Annex B (normative) Test method for dose accuracy...27
  • Annex C (normative) Visual inspection and container inspection...36
  • Annex D (informative) Dose combinations, accuracy and test description...37
  • Annex E (normative) Free fall test...39
  • Annex F (informative) Illustration...41
  • Annex G (normative) Unilateral and bilateral tolerance factor k...45
  • Bibliography...57

Foreword

YY/T 1768 "Needle-based injection systems for medical use - Requirements and test

methods" consists of the following parts.

- Part 1.Needle-based injection systems;

- Part 2.Needles;

- Part 3.Containers;

- Part 4.Electronic and electromechanical pen injectors;

- Part 5.Automatic functions;

- Part 7.Accessibility services for the visually impaired.

This Part is Part 1 of YY/T 1768.

This Part was drafted in accordance with the rules given in GB/T 1.1-2009.

This Part uses redrafting method to refer to ISO 11608-1.2014 "Needle-based injection

systems for medical use - Requirements and test methods - Part 1.Needle-based

injection systems". The degree of conformity with ISO 11608-1.2014 is non-equivalent.

Attention is drawn to the possibility that some of the elements of this document may be

the subject of patent rights. The issuing authority shall not be held responsible for

identifying any or all such patent rights.

This Part was proposed by National Medical Products Administration.

This Part shall be under the jurisdiction of National Technical Committee on Medical

Syringe (Needle) of Standardization Administration of China (SAC/TC 95).

The drafting organizations of this Part. Shandong Weigao Group Medical Polymer

Products Co., Ltd., Shanghai Medical Device Testing Institute, China National Institute

for Food and Drug Control, Novo Nordisk (China) Pharmaceutical Co., Ltd., Shanghai

Food and Drug Administration Certification and Evaluation Center.

Main drafters of this Part. Li Weiyang, Liu Xinglin, Zhang Binbin, Fu Bufang, Qian

Yujun, Liu Qun.

1 Scope

This Part of YY/T 1768 specifies the requirements and test methods for needle-based

injection systems.

This Part applies to needle-based injection systems intended for use with needles and

containers, such as pen injectors.

The containers described in this Part include single-dose, multi-dose syringe systems

and cartridge systems filled by the manufacturer or end user.

This Part does not apply to needleless syringes.

This Part does not address requirements and related methods for filling containers and

appliances by the end user.

2 Normative references

The following referenced documents are indispensable for the application of this

document. For dated references, only the edition cited applies. For undated references,

the latest edition of the referenced document (including any amendments) applies.

GB/T 2423.4-2008, Environmental testing for electric and electronic products - Part

2 Test method - Test Db. Damp heat, cyclic (12 h + 12 h cycle) (IEC 60068-2-

30.2005, IDT)

GB/T 2423.10-2019, Environmental testing - Part 2.Test methods - Test Fc.

Vibration (sinusoidal) (IEC 60068-2-6.2007, IDT)

GB/T 3359-2009, Statistical interpretation of data - Determination of statistical

tolerance intervals (ISO 16269-6.2005, IDT)

GB/T 16886.1, Biological evaluation of medical devices - Part 1.Evaluation and

testing within a risk management process (GB/T 16886.1-2011, ISO 10993-1.2009,

IDT)

GB/T 18779.1, Geometrical Product Specifications (GPS) - Inspection by

measurement of workpieces and measuring equipment - Part 1.Decision rules for

proving conformance or non-conformance with specifications (GB/T 18779.1-2002,

eqv ISO 14253-1.1998)

3 Terms and definitions, symbols and abbreviations

3.1 Terms and definitions

The following terms and definitions apply to this document.

3.1.1 cap

A component used in a needle-based injection system to protect the syringe and its

contents.

3.1.2 container

A primary packaging that contains injectable drug product (single or multi-chamber).

3.1.6 "dose delivered" indication

The number displayed in the dose window indicating the dose of the drug product to be

delivered.

3.1.7 manufacturer-filled

A container that is prefilled with a drug by a drug manufacturer and is supplied to a user.

3.1.8 minimum deliverable dose

The manufacturer ensures that in a single-dose manufacturer-filled needle-based

injection system, the minimum dose delivered is designed to the one that can empty the

container.

3.1.9 needle-based injection system

An injection system for injecting parenteral drugs through the use of a needle and a

multi-dose or single-dose container.

3.1.12 user packaging

A package or set of identical needle-based injection systems from the same

manufacturing lot provided to the user, including instructions for use.

3.1.13 user-filled

Containers filled by the user from individual drugs or container after reconstitution with

diluent (if drug product is lyophilized).

3.2 Symbols and abbreviations

The following symbols and abbreviations apply to this document.

DR. Set resolution, the smallest adjustable increment of NIS.

NIS. Needle-based injection system.

RF. Radiated radio frequency.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 57 pages — is available in the English PDF.

Referenced standards

How to Download YY/T 1768.1-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
57 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1768.1-2021

$500.00