YY/T 1659-2019General technical requirements for intravascular ultrasound(IVUS) diagnostic equipment (English PDF)
血管内超声诊断设备通用技术要求
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1659-2019 in 30 minutes.
Issued by
National Medical Products Administration of the People's Republic of China
Level / Type
Industry · Recommended
Issue date
July 24, 2019
Implementation date
August 1, 2020
Scope
YY/T 1659-2019 is the English-translated version of 血管内超声诊断设备通用技术要求.
YY/T 1659-2019 is the Chinese standard "General technical requirements for intravascular ultrasound(IVUS) diagnostic equipment". Its scope clause reads: This standard specifies the requirements and test methods for intravascular ultrasound diagnostic equipment (hereinafter referred to as equipment).
This standard applies to ultrasound diagnostic equipment for intravascular imaging with acoustic operating frequencies of 60 MHz and below. Note. Ultrasonic transducer assemblies for use in human blood vessels can typically be imaged over a 360° range.
This standard does not consider all possible complex appearances of the transducer And shape, the test method of the parameters is taken as an example of 360° cylindrical imaging.
If necessary, the user of this standard can use the basic method described in the standard to be more complicated. Design to apply. Its clauses include terms and definitions.
Found what you need?
Document preview — YY/T 1659-2019
National Standard of the People's Republic of China
- ICS
- 11.040.55
- Classification
- C 41
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.
1 Scope
This standard specifies the requirements and test methods for intravascular ultrasound diagnostic equipment (hereinafter referred to as equipment).
This standard applies to ultrasound diagnostic equipment for intravascular imaging with acoustic operating frequencies of 60 MHz and below.
Note. Ultrasonic transducer assemblies for use in human blood vessels can typically be imaged over a 360° range. This standard does not consider all possible complex appearances of the transducer
And shape, the test method of the parameters is taken as an example of 360° cylindrical imaging. If necessary, the user of this standard can use the basic method described in the standard to be more complicated.
Design to apply.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB 9706.1 Medical electrical equipment - Part 1. General requirements for safety
GB 9706.9 Medical electrical equipment - Part 2-37. Particular requirements for safety of ultrasonic diagnostic and monitoring equipment
GB/T 14710 Medical electrical requirements and test methods
YY 0285.1 Intravascular catheters - Sterile catheters - Part 1 . General requirements
YY/T 1420 Medical Ultrasound Equipment Environmental Requirements and Test Methods
3 Terms and definitions
The following terms and definitions as defined in GB 9706.1, GB 9706.9 and YY 0285.1 apply to this document.
3.1 Intravascular ultrasound diagnostic equipment
For medical examination of intravascular ultrasound, medical electronics consisting of a host and a mating ultrasound transducer assembly intervening in the human blood vessels device.
3.2 Test piece testobject
An ultrasonic echo imaging performance detecting device composed of one or more sets of target structures.
3.3 Imaging radius
A longitudinal linear target group that can be clearly imaged in the test piece or between the farthest target line in the target and the geometric central axis of the ultrasonic transducer assembly distance.
Note. The unit is millimeter (mm).
3.4 Retraction direction resolution
The minimum distance between the two target lines of the two clear echo signals can be displayed when the transducer is retracted radially along the catheter.
Note. The unit is millimeter (mm).
YY/T 1749-2020 | YY/T 1676-2020 | YY/T 1671-2020 | YY/T 1919-2023 | YY/T 1668-2019 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 9706.1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
- GB/T 14710The environmental requirement and test methods for medical electrical equipment
- YY 0285.1Intravascular catheters—Sterile and single-use catheters - Part 1: General requirements
- YY/T 1420Environmental requirement and test methods for medical ultrasonic equipment
GB 9706.9
How to Download YY/T 1659-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 9706.1-2020 — Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
GB/T 14710-2009 — The environmental requirement and test methods for medical electrical equipment
YY 0285.1-1999 — Sterile, single-use intravascular catheters - Part 1: General requirements
Secure payment via Stripe
Payments accepted
YY/T 1659-2019
$150.00