YY/T 1586-2018Individualized treatment tumor related gene mutation detection kit(Fluorescent PCR) (English PDF)
肿瘤个体化治疗相关基因突变检测试剂盒(荧光PCR法)
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1586-2018 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
February 24, 2018
Implementation date
March 1, 2019
Scope
YY/T 1586-2018 is the English-translated version of 肿瘤个体化治疗相关基因突变检测试剂盒(荧光PCR法).
YY/T 1586-2018 is the Chinese pharmaceutical industry standard for kits that detect the gene mutations used to individualise cancer treatment, by real-time fluorescent PCR.
It sets the requirements, the test methods, the labels and instructions for use and the rules for packaging, transport and storage, covering the detection limit in terms of mutant fraction and template quantity, the specificity against the wild-type sequence and other mutations, the accuracy against reference materials, the repeatability, the internal control and the stability. Issued on 24 February 2018, it has applied since 1 March 2019.
Found what you need?
Document preview — YY/T 1586-2018
National Standard of the People's Republic of China
- ICS
- 11.100
- Classification
- C 44
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Requirements
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the requirements, test methods, labels, instructions for use, and kits for the detection of gene mutation detection kits for individualized treatment of tumors. Loading, transport and storage.
This standard applies to the nucleic acid detection technology of real-time fluorescent PCR method for gene mutation related to tumor individualized treatment.
The types of gene mutations referred to in this standard include base substitution, transversion, insertion, deletion, and the like.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 29791.2 Information provided by in vitro diagnostic medical device manufacturers (labeling) Part 2. Professional in vitro diagnostic reagents
3 Requirements
3.1 Appearance
The components of the kit should be complete and complete, and the liquid should be free of leakage.
3.2 Positive coincidence rate
Positive national reference products and/or standardized enterprise reference products within the scope of the test kit, the test results should be positive and consistent with the corresponding Variable type.
The setting of positive reference products should follow the following principles.
a) all types of mutations detectable within the scope of the kit;
b) 3 mutation percentage gradients for each mutation site, weak positive reference. no more than 3 times the detection limit mutation rate; medium positive Reference product. mutation rate is not higher than 40%; strong positive reference product. mutation rate is not less than 70%;
c) In the positive reference composition used, the matrix of the common mutation site reference should be the same or similar to the actual test sample matrix.
3.3 Negative compliance rate
Test negative national reference products and/or standardized enterprise reference products, the test results should be negative or wild type.
The setting of the negative reference should follow the following principles.
a) should contain a certain number of non-human genome samples. common microbial samples;
b) wild-type samples without corresponding target mutant sequences;
c) Genotype or gene mutation samples outside the scope of the kit design.
3.4 Detection limit
National reference products and/or standardized enterprise reference products within the scope of the test kit, the test results should be positive and consistent with the corresponding mutation
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 1586-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 29791.2-2013 — In vitro diagnostic medical devices -- Information supplied by the manufacturer (labelling) -- Part 2: In vitro diagnostic reagents for professional use
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field
Secure payment via Stripe
Payments accepted
YY/T 1586-2018
$85.00