YY/T 1560-2017Spinal implant—Standard test methods for occipital-cervical and occipital-cervical-thoracic implant constructs in a vertebrectomy model (English PDF)

脊柱植入物椎体切除模型中枕颈和枕颈胸植入物试验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1560-2017 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

March 28, 2017

Implementation date

April 1, 2018

Scope

YY/T 1560-2017 is the English-translated version of 脊柱植入物椎体切除模型中枕颈和枕颈胸植入物试验方法.

YY/T 1560-2017 is the Chinese pharmaceutical industry standard that gives the static and fatigue test methods for occipital-cervical and occipito-cervico-thoracic implant assemblies in a vertebrectomy model.

It sets the materials of the test construct, which follow the intended site and technique, the loading and the number of cycles, and the measurements taken, so that the mechanical behaviour of such constructs can be compared across designs and over time. Issued on 28 March 2017, it has applied since 1 April 2018.

Found what you need?

Document preview — YY/T 1560-2017

National Standard of the People's Republic of China

ICS
11.040.40
Classification
C 35

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This standard specifies the materials and methods of static and fatigue tests of the occipitocervix and occipito-cervical implant components in a vertebral body excision model. most The test material for the occipitoccipital and occipito-cervical implant components depends on the intended site of implantation and the method of application.

This test method is intended to provide a basis for the comparison of the mechanical properties of occipitoccipital and occipito-cervical implant components in the past, present and future, The method can be used to compare the occipito-cervical and occipito-cervical thoracic implants that are expected for different application sites and methods of application. The purpose of these test methods It is not intended to define the performance level as there is not enough information to predict the outcome of an implant.

This standard provides guidelines for loading types and loading methods and provides for the comparative evaluation of occipitoccipital and occipito-cervical implant components three Static test methods and two fatigue test methods. This test method is to measure the displacement, determine the yield load and evaluate the occipital or occipitocervix The rigidity and strength of the implant assembly establish the guiding principle. Some occipito-cervical or occipito-cervical implants may not be suitable for use in accordance with this standard Test configuration for testing.

This standard is not intended to address all the safety issues involved, even those related to their use safety issues. establish Appropriate safety and health practices, as well as the applicability of a clear management limit before application, are the sole responsibility of the user of this standard.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 16825.1 static uniaxial testing machine test Part 1. Tensile and (or) pressure testing machine testing system and force measurement calibration

YY/T 0857 vertebral excision model of spinal implant test methods Spinal implant interbody fusion cage mechanical properties test method

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Longitudinal part of the working length

The linear distance between the center of rotation of the test block.

3.2 Arm blockmomentarm

Vertical line from the point where the screw is inserted to the hinge pin axis.

3.3 Compression or tensile bending stiffness

Compression or tensile bending yield load divided by the elastic displacement (see Figure 1, the initial slope of BC).

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 1560-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1560-2017

$295.00