Scope

YY/T 1401-2016 is the English-translated version of 牙齿美白冷光仪.

YY/T 1401-2016 is the Chinese pharmaceutical industry standard for the cold light unit used in tooth whitening, the lamp that activates the whitening gel on the teeth.

It sets the requirements and the test methods, covering the spectrum and the irradiance delivered at the treatment distance and their accuracy, the heat radiated towards the pulp and the soft tissue, the timer, the arm and the stability of the unit, and the electrical safety. Issued on 23 March 2016, it has applied since 1 January 2017.

Found what you need?

Document preview — YY/T 1401-2016

National Standard of the People's Republic of China

ICS
11.060.20
Classification
C 33

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 normative reference document
  • 3 Terms and definitions
  • 5 request
  • 6 Test Method
  • 7 Information provided by the manufacturer

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009.

Introduction

For the tooth whitening cold light meter in the 400nm to 650nm wavelength range of light radiation value, this standard did not make the request, but the application of this standard The prospective manufacturers should specify the radiation values in this wavelength range in their information vehicles.

This standard provides a tooth whitening cold light instrument designed to dental clinics, to cover the surface of the whitening agent to provide light source irradiation, so that whitening The chemical reaction takes place under light irradiation.

1 Scope

This standard specifies the requirements and test methods for dental whitening cold light.

This standard applies to the teeth whitening cold light instrument (hereinafter referred to as "cold light instrument", as defined in 3.1). In dental clinics, the cold light meter is covered The whitening agent on the surface of the tooth provides a light source to cause the whitening agent to undergo a chemical catalytic reaction under light irradiation.

This standard applies to the use of halogen bulbs and/or LED lights as a light source of the cold instrument.

This standard does not apply to the use of laser as a light source of the cold instrument.

2 Normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.

GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (IEC 60601-1. 1988, IDT) A permanent medical device that produces cold light in a specific wavelength range, which emits a whitening agent applied to the tooth surface, Chemical reaction occurs under irradiation.

GB/T 9937 (all parts) Oral vocabulary [ISO 1942 (all parts)]

Light safety of light and light systems (CIES009/E..2002, IDT) GB/T 20145-2006

3 Terms and definitions

GB/T 9937 (all parts) as defined and the following terms and definitions apply to this document.

4 Classification

GB 9706.1-2007 in Chapter 5 and the following classification applies.

According to the power supply, cold light instrument is divided into.

--- Type 1. Power supply via network;

--- Type 2. Powered by rechargeable battery.

5 Request

5.1 General requirements

The cold light meter shall be designed, constructed and manufactured for proper transport, storage, installation, use and maintenance in accordance with the manufacturer's instructions, The cold light meter in the normal use and a single failure state will not be on the patient, the operator or the surrounding environment can be reasonably foreseeable Danger.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.

Referenced standards

How to Download YY/T 1401-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
16 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1401-2016

$145.00