YY/T 1241-2014L-Lactate dehydrogenase test reagent(kit) (English PDF)
乳酸脱氢酶测定试剂(盒)
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1241-2014 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
June 17, 2014
Implementation date
July 1, 2015
Scope
YY/T 1241-2014 is the English-translated version of 乳酸脱氢酶测定试剂(盒).
YY/T 1241-2014 is the Chinese pharmaceutical industry standard for the L-lactate dehydrogenase assay reagent kit that measures the enzyme by continuous monitoring with lactate as the substrate.
It gives the terms and definitions, the requirements, the test methods, the labels, the instruction leaflet and the rules for packaging, transport and storage, the requirements covering appearance, the blank absorbance, analytical sensitivity, linearity, precision, accuracy and stability.
It applies to kits for the quantitative determination of lactate dehydrogenase activity in serum or plasma, whether used manually or on a semi-automatic biochemical analyser, and not to dry-type kits. Issued on 17 June 2014, it has applied since 1 July 2015.
Found what you need?
Document preview — YY/T 1241-2014
National Standard of the People's Republic of China
- ICS
- 11.100
- Classification
- C 44
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Requirements
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
1 Scope
This standard specifies the lactate dehydrogenase assay reagent (box) terms and definitions, requirements, test methods, labels, brochures, packaging, transport Transport and storage requirements.
This standard applies to lactate as substrate using the method of continuous monitoring of serum or plasma lactate dehydrogenase activity quantitative detection Lactate dehydrogenase assay reagent (kit), including manual reagents and on the semi-automatic biochemical analyzer used.
This standard does not apply to dry-type lactate dehydrogenase assay reagent (kit).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 3100 International System of Units and Its Application
GB/T 21415 in vitro diagnostic medical devices - Measurement of quantities in biological samples calibration and control materials assigned metrological traceability Derived
YY/T 0316 Medical Devices Risk Management for Medical Device Applications Symbols - Part 1 YY/T 0466.1 medical equipment used with medical device labels, labeling and information. General requirements
YY/T 0638 in vitro diagnostic medical devices - Measurement of quantities in biological samples calibration and control materials in enzymatic concentration assignment Metrological traceability
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1 Continuous monitoring method
Under optimum conditions the enzyme reaction, multi-point monitoring throughout the course of the enzymatic reaction product or a reaction in the substrate due to changes over time Case, the reaction rate constant period, in the initial reaction rate per unit time of enzyme activity concentration of the enzyme was calculated.
4 Requirements
4.1 Appearance
In line with the provisions of the company's normal appearance requirements.
4.2 PACKING
Loading amount of the liquid reagent to be less than indicated value.
4.3 Reagent blank
4.3.1 Reagent blank absorbance
At 37 °C, 340nm wavelength, under 1cm light path conditions, absorbance of the reagent blank should be less than 0.50.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 3100SI units and recommendations for the use of their multiples and of certain other units
- GB/T 21415In vitro diagnostic medical devices - Requirements for establishing metrological traceability of values assigned to calibrators, trueness control materials and human samples
- YY/T 0316Medical devices-Application of risk management to medical devices
- YY/T 0638In vitro diagnostic medical devices - Measurement of quantities in biological samples - Metrological traceability of values for catalytic concentration of enzymes assigned to calibrators and control materials
Similar standards
How to Download YY/T 1241-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 3100-1993 — SI units and recommendations for the use of their multiples and of certain other units
GB/T 21415-2008 — In vitro diagnostic medical devices - Measurement of quantities in biological samples - Metrological traceability of values assigned to calibrators and control materials
GB/T 21415-2025 — In vitro diagnostic medical devices - Requirements for establishing metrological traceability of values assigned to calibrators, trueness control materials and human samples
Secure payment via Stripe
Payments accepted
YY/T 1241-2014
$205.00