YY/T 1240-2014D-Dimer reagent (kit) (English PDF)
D-二聚体定量检测试剂(盒)
This is a limited preview
Buy now to download the full PDF (25 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1240-2014 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
June 17, 2014
Implementation date
July 1, 2015
Scope
YY/T 1240-2014 is the English-translated version of D-二聚体定量检测试剂(盒).
YY/T 1240-2014 is the Chinese pharmaceutical industry standard for the D-dimer quantitative reagent kit used in the laboratory to measure the fibrin degradation product that rises in thrombosis.
It gives the terms and definitions, the requirements the kit must meet, the test methods, the symbols, labels and instructions for use, and the rules for packaging, transport and storage.
It applies to immunoturbidimetric D-dimer reagents, and its informative appendices explain how patient assessment and pre-test probability are used together with the result and what the clinical use of a D-dimer measurement can and cannot show.
It is written for manufacturers of the kits and for the clinical laboratories that run them. Issued on 17 June 2014, it has applied since 1 July 2015.
Found what you need?
Document preview — YY/T 1240-2014
National Standard of the People's Republic of China
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and definitions4
- 4 Requirements5
- 5 Test methods6
- 6 Marks, labels and instructions8
- 7 Packaging, transportation and storage10
- Annex A (Informative) The application of patient assessment and pre-test probability12
- Annex B (Informative) Applicable instructions about D-Dimer13
- Bibliography15
Foreword
This Standard is drafted according to the rules specified in GB/T 1.1-2009.
1 Scope
This Standard specifies the term and definition, requirements, test methods, symbols, labels and instructions, packing, transportation, and storage of D-Dimer quantitative detection reagent (kit).
This Standard applies to immunoturbidimetric D-Dimer reagent (kit) (hereinafter referred to as D-D reagent) used in laboratory.
2 Normative references
The articles contained in the following documents have become part of this Document when they are quoted herein. For the dated documents so quoted, all the modifications (Including all corrections) or revisions made thereafter shall be applicable to this document.
GB/T 191 Packaging - Pictorial marking for handling of goods
GB 3100 The international system of units and its application
GB 3101 General principles concerning quantities, units and symbols
GB 3102 (All parts) Quantities and Units
YY/T 0466.1-2009 Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements
3 Terms and definitions
For the purpose of this Document, the following terms and definitions apply.
3.1 Immunoturbidimetric D-dimer assay
The homogeneous latex particles, coated by monoclonal antibody, COMBINE with the degradation product's specificity of the soluble fibrin of D-D antigen determinants in plasma. So that it makes the latex particles to coagulate each other. The coagulation degree is proportional to the concentration of D-Dimer in the specimen. At certain
5.7 Report pattern
VERIFY the reporting template. It shall meet the requirements specified in 4.6.
6 Marks, labels and instructions
6.1 General requirements
The general requirements of symbols, labels and instructions are as follows.
a) The form and content of the labels and instructions shall adapt to the expected uses of the reagent (kit);
b) Use the symbols specified in YY/T 0466.1.If there is no relevant standard or users fail to understand the symbols used, those symbols and colors shall be explained in the instructions;
c) The numerical unit provided shall be understood by users. Use the symbols specified in GB 3100-3102;
d) The microbiological status of the product shall be explained when using the product;
e) Unless it is easy to know how to use the reagent (kit), there shall have instructions.
- There shall have relevant instructions or symbols to prompt users to carefully read the instructions before using the reagent (kit);
- The language used in the instructions shall be understood by the expected users;
f) Emphasize and prompt users the important changes of the reagent (kit) and the position of the relevant information;
g) Warn users the possible risks and dangers by words or symbols;
h) The name, letter, number, symbol, color and graph of each component of the reagent (kit) shall be marked in the same way;
i) The reagent instructions can be put in the packing as separated pages, which can be on the external surface of the container, in the manual, in the operation manual, or integrated with the instructions of the instruments or analyzing system.
j) The reagent instructions can be in electronic version.
k) Some of the instructions can be provided in a coded form, and be explained in the system operation manual;
l) If there is no detailed instructions attached to the reagent (kit), the manufacturing enterprise shall make sure that users can get a correct version of the reagent (kit) instructions;
m) The labels of the exterior packing and initial packing shall include the required information, which shall be described by intelligible words or symbols;
Examples. The quality, font and font size of the printing;
n) The labels and instructions provided with the reagent (kit) shall include how to handle and store the reagent before using.
6.2 Labels for outer packing
The label in the exterior packing shall provide the following information.
a) Reagent name;
b) Packaging specifications;
c) IVD reagents;
d) Storage conditions;
e) Batch number;
f) Valid period;
g) Registration certificate number;
h) Product standard number;
i) Name and address of manufacturing enterprise.
6.3 Labels for inner packing
The label in the interior packing shall provide the following information.
a) Reagent name;
b) Packaging specifications;
c) Storage conditions;
d) Batch number;
e) Valid period;
f) Name of the manufacturing enterprise.
6.4 Operating instructions
B.2.3.3 When performing clinical assessment, the tested reagent shall be compared with another D-dimer reagent system that has been confirmed by authentic institution and possesses the VTE diagnosing function.
B.2.3.4 Negative predictive value (NPV) is 97% and above (lower limit of 95% confidence interval is not lower than 95%). The auxiliary diagnosis has no specific requirement to sensitivity.
B.2.4 Used for the exclusion diagnosis of VTE
B.2.4.1 Characteristics. The clinical doctor excludes the VTE through
D-dimer experiment, combining PTP.
B.2.4.2 The VTE-suspected patients are continuously selected in clinical research. It shall be performed at 3 centers at least. The 3 centers use the same PTP principle. The sample size possesses the statistical significance (Both incidences of DVT and PE >10%).
B.2.4.3 The clinical assessment takes the imaging diagnosis result (clinical fact) as the criterion. If the imaging diagnosis does not confirm VTE, then the patient will be traced for 3 months to confirm the negative result.
B.2.4.4 Negative predictive value (NPV) is 97% and above (lower limit of 95% confidence interval is not lower than 95%). The sensibility is not lower than 95% (the lower level of 95% confidence interval is not lower than 90%).
Bibliography
1) Huang Yueqin. Clinical Epidemiology. Beijing. People's Medical Publishing House,
2) Jack Hirsh, Agnes Y. Y. Lee. How we diagnose and treat deep vein thrombosis. Blood, 2002.99.3102-3110
3) Wells, P.s.., D.R. Anderson, et al. Evaluation of D-dimer in the diagnosis of suspected deep-vein thrombosis. N Engl J Med. 2003; 349 (13). 1227-1235.
4) Clinical and Laboratory Standards Institute. Quantitative D-dimer for the Exclusion of Venous Thromboembolic Disease; Approved Guideline. CLSI document H59-A(ISBN 1-56238-747-2)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB 3100SI units and recommendations for the use of their multiples and of certain other units
- GB 3101Quantities and units. General principles
- YY/T 0466.1-2009Medical devices - Symbols to be used with information to be supplied by the manufacturer - Part 1: General requirements
GB 3102
Similar standards
How to Download YY/T 1240-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 3100-1993 — SI units and recommendations for the use of their multiples and of certain other units
GB 3101-1993 — Quantities and units. General principles
GB 3102.1-1993 — Quantities and units of space and time
YY/T 1240-2014
$135.00