YY/T 1198-2013Aspartate aminotransferase diagnostic kit(IFCC method) (English PDF)
天门冬氨酸氨基转移酶测定试剂盒(IFCC法)
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1198-2013 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
October 21, 2013
Implementation date
October 1, 2014
Scope
YY/T 1198-2013 is the English-translated version of 天门冬氨酸氨基转移酶测定试剂盒(IFCC法).
YY/T 1198-2013 is the Chinese pharmaceutical industry standard for the aspartate aminotransferase diagnostic kit made to the IFCC method.
It specifies the principle of the determination, the requirements, the test methods, the marks, the signs, the instructions and the rules for packaging, transport and storage, covering the appearance, the blank absorbance, the traceability of the calibrator, the accuracy, the linear range, the precision, the interference and the stability of the reagents. Issued on 21 October 2013, it has applied since 1 October 2014.
Found what you need?
Document preview — YY/T 1198-2013
National Standard of the People's Republic of China
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative References
- 3 Determination Principle
- 4 Requirements
- 6 Mark, Label and Instructions
- 7 Packaging, Transport and Storage
Foreword
This Standard was drafted in accordance with the rules specified in GB/T 1.1-2009.
1 Scope
This standard specifies the determination principle, requirements, test method, marks, signs, instructions, packaging, transport and storage of aspartate aminotransferase diagnostic kit (lFCC method).
This standard applies to the quality control of aspartate aminotransferase diagnostic kit (lFCC method) This product is used for in-vitro quantitative determination of the aspartate aminotransferase activity in human serum or plasma.
2 Normative References
The following documents are indispensable for the application of this Document. For dated references, only dated edition applies to this document. For undated references, the latest edition (including all amendments) applies to this document.
YY/T 0466.1 Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements
GB/T 191 Packaging - Pictorial Marking for Handling of Goods
3 Determination Principle
This method is the method recommended by IFCC. The reaction equation of method principle is as follows.
L-aspartic acid + alpha-ketoglutaric acid -> oxaloacetic acid + L-glutamic acid
Oxaloacetic acid + NADH + H+ -> L-malic acid + NAD+ In the above coupled reaction, the oxidation rate of NADH is proportional to the enzymatic activity of the specimen. NADH has characteristic absorption peak at the wavelength of 340 nm.
Therefore, the activity of ALT can be calculated through measuring the decline rate of NADH absorbance.
The amino of L-aspartic acid will be transferred to malic dehydrogenase (MDH) under the catalysis of AST. Then carry out coupled reaction; oxidize the NADH to NAD+. NADH has characteristic absorption peak at the wavelength of 340 nm. Its oxidation rate is proportional to the activity of AST in serum. Therefore, the activity of ALT (U/L) can be calculated through measuring the decline rate of NADH absorbance at 340 nm.
4 Requirements
4.1 Appearance
It shall meet the appearance requirements specified by the manufacturer.
5.8 Stability
Take the reagent (kit), which is stored to the expiry of validity period under the specified storage conditions OR under the accelerated test conditions specified by the manufacturer, for test. It shall meet the requirements of 4.8.
6 Mark, Label and Instructions
6.1 Mark and label of kit packaging box
The packaging-pictorial marking for handling of goods shall meet the requirements of GB/T 191, and shall include at least the following contents.
a) Product name and specification;
b) Production batch number;
c) Expiry date; d) Storage conditions.
6.2 Mark and label of single kit packaging bottle
The single kit packaging bottle shall include the following contents.
a) Product name and specification;
b) Trademark;
c) Net content of product;
d) Production batch number;
e) Expiry date; f) Storage conditions.
6.3 Instructions
The instructions shall include the following contents.
a) Product name;
b) Packaging specification;
c) Intended use;
d) Test principle;
e) Main components;
f) Storage conditions and expiry date;
g) Applicable instruments;
h) Sample requirements;
i) Test method;
j) Reference value (reference interval);
k) Explanation of test results;
l) Limitation of the test method;
m) Product performance index;
n) Precautions;
o) References;
p) Manufacturing enterprise;
q) Production enterprise license number of medical device;
r) Registration certificate number of medical device;
s) Product standard number;
t) Approval and modification date of the instructions.
7 Packaging, Transport and Storage
7.1 Packaging
7 1.1 Packaging for storage and transport The packaging for storage and transport AND marking of the kit shall meet the requirements of GB/T 191.
7.1.2 Unit packaging
7.1.2.1 The kit shall be complete, labeled clearly, sealed tightly, and free of leakage.
7.1.2.2 The instructions shall be enclosed within the kit.
7.2 Transport
Product transport shall be carried out according to the provisions of contract.
7.3 Storage
Kit shall be stored under the conditions specified by the manufacturer. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 1198-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 191-2000 — Packaging-Pictorial marking for handling of goods
GB/T 191-2008 — Packaging - Pictorial marking for handling of goods
GB/T 191-2025 — Graphical symbols marking for handling and storage of packages
YY/T 1198-2013
$125.00