Scope

YY/T 1177-2010 is the English-translated version of 癌抗原CA72-4定量测定试剂(盒)(化学发光免疫分析法).

YY/T 1177-2010 is the Chinese pharmaceutical industry standard for the reagent kit that measures the cancer antigen CA72-4 quantitatively by chemiluminescent immunoassay.

It specifies the classification, the requirements, the test methods, the marking, the labelling, the instruction manual and the rules for packaging, transport and storage, covering the appearance, the traceability of the calibrator, the accuracy, the linear range, the detection limit, the precision, the hook effect and the stability. Issued on 27 December 2010, it applies from 1 June 2012.

Found what you need?

Document preview — YY/T 1177-2010

National Standard of the People's Republic of China

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Classification4
  • 4 Requirements5
  • 5 Test methods6
  • 6 Marking, labeling, and instruction manual9
  • 7 Packaging, transportation, and storage11
  • References12

Foreword

This Standard was drafted according to the rules specified in GB/T 1.1-2009.

This Standard is the basis for evaluating the product quality of CA72-4 (Cancer Antigen 72-4, CA72-4) quantitative determination reagent (kit) (chemiluminescent immunoassay).

1 Scope

This Standard specifies the classification, requirements, test methods, marking, labeling, instruction manual, packaging, transportation, and storage of the cancer antigen CA72-4 quantitative detection reagent (kit) (chemiluminescent immunoassay).

This Standard applies to the quantitative detection of cancer antigen CA72-4 reagent (kit) [hereinafter referred to as "CA72-4 reagent (kit)"] based on the principle of chemiluminescent immunoassay. It includes the enzymatic and non-enzymatic chemiluminescent immunoassay detection reagent (kit) with the carriers such as microplates, pipes, magnetic particles, microbeads, and plastic beads. The Standard does not apply to.

a) The tumor marker calibrator and tumor marker quality control materials intended for separate sales.

b) Biochip in the principle of chemiluminescent immunoassay.

2 Normative references

The provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this Standard.

GB/T 21415-2008 In vitro diagnostic medical devices - Measurement of quantities in biological samples - Metrological traceability of values assigned to calibrators and control materials (ISO 17511:2003, IDT)

3 Classification

CA72-4 reagent (kit) can be divided into enzymatic and non-enzymatic chemiluminescent immunoassay detection reagent (kit), according to different chemiluminescence principles. According to different solid-phase carriers, it can be divided into enzymatic and non-enzymatic chemiluminescent immunoassay detection reagent (kit) with carriers such as microplates, pipes, magnetic particles, microbeads, and plastic beads. According to different operation processes, it can be divided into manual operation method and automatic operation method of instrument. CV - Coefficient of variation;

SD - Standard deviation of the measured results for 10 times; M - Mean of the measured results for 10 times.

5 Test methods

5.8 Stability

It can choose the following methods to perform verification.

a) Stability within the period of validity. TAKE the expired sample to inspect according to the methods of 5.3-5.6. It shall comply with the requirements of 4.8 a).

b) Thermal stability test. TAKE the sample within the period of validity to place for 3 days under the condition of 37°C. PERFORM the detection according to the methods of 5.3-5.6. It shall comply with the requirements of 4.8 b).

6 Marking, labeling, and instruction manual

6.1 Marking and labeling of reagent's (kit) outer packing

It shall include at least the following contents.

a) Product name and package specifications;

b) Name, address, contact details of manufacturing enterprise or after-sales service organization;

c) Medical device registration certificate number

d) Product standard number;

e) Product batch number;

f) Expiry date; g) Storage conditions.

6.2 Marking and labeling of reagent's (kit) each component's packing

It shall include at least the following contents.

a) Product name and package specifications;

b) Name or logo of manufacturing enterprise;

c) Product batch number;

v) Instructions approval and modification date.

6.2 Transportation

Reagents (kit) shall be transported according to the requirements of manufacturing enterprises.

6.3 Storage

Reagent (kit) shall be stored under the conditions specified by manufacturing enterprises.

References [1] GB/T 191 Packaging - Pictorial marking for handling of goods [2] GB/T 9969 General principles for preparation of instructions for use of industrial products [3] YY 0466 Medical devices - Symbols to be used with medical device labels labeling and information to be supplied (ISO 15223-2000, IDT)

[4] GB/T 19702-2005 In vitro diagnostic medical devices - Measurement of quantities in samples of biological origin - Requirements for content and presentation of reference measurement procedures (ISO 15193:2002, IDT)

[5] ISO/DIS 18113-1 Clinical laboratory testing and in vitro diagnostic medical systems - Information supplied by the manufacturer (labeling) - Part 1: Terms, definitions and general requirements

7 Packaging, transportation, and storage

7.1 Packaging

Reagents (kit) shall be packaged according to the requirements of manufacturing enterprise. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 1177-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1177-2010

$125.00