Valid

YY/T 0957.1-2014Orthopaedic instruments - Drive connections - Part 1: Keys for use with screws having hexagon socket heads (English PDF)

矫形工具拧动接头 第1部分:内六角螺钉用扳手

Open the YY/T 0957.1-2014 preview as PDF

Preview — first pages of YY/T 0957.1-2014 (full document: 17 pages)

This is a limited preview

Buy now to download the full PDF (17 pages)

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

June 17, 2014

Implementation date

July 1, 2015

Scope

YY/T 0957.1-2014 is the English-translated version of 矫形工具拧动接头 第1部分:内六角螺钉用扳手.

YY/T 0957.1 standardises the hexagon socket key used to drive orthopaedic screws, the most common drive interface in trauma and spinal implant systems. It is Part 1 of the Chinese series on orthopaedic instrument drive connections, with Part 2 covering slotted and cross recess drivers. The dimensions and tolerances it fixes are what determine whether the key engages fully, transmits the torque a locking screw needs, and comes out again without rounding the socket, which in a surgical setting is the difference between a routine step and an unplanned revision of technique. For a manufacturer of orthopaedic instrumentation or implant screws for the Chinese market, this is the governing dimensional standard for the interface.

Document preview — YY/T 0957.1-2014

National Standard of the People's Republic of China

ICS
11.040.40
Classification
C35

Issued by: National Medical Products Administration

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Dimensions and tolerances

Foreword

YY/T 0957 "joint orthopedic tool twist" is divided into two parts.

--- Part 1. socket head cap screws with a wrench;

--- Part 2. slotted, Phillips slot and Phillips screws with a screwdriver. This section YY/T Section 10957 of. This section drafted in accordance with GB/T 1.1-2009 given rules. Consistency correspondence between this part of international documents and normative references of our files are as follows:

--- GB/T 230.1 metallic materials - Rockwell hardness test - Part 1. Test methods (A, B, C, D, E, F, G, H, K, N, T Ruler) (GB/T 230.1-2009, ISO 6508-1.2005, MOD)

--- YY/T 0294.1 surgical instrument metallic materials - Part 1. Stainless steel (YY/T 0294.1-2005, ISO 7153-1. 1991, MOD)

--- YY/T 0605.5 surgical implants of metallic materials - Part 5. Wrought cobalt - chromium - tungsten - nickel alloy (YY/T 0605.5- 2007, ISO 5832-5.2005, IDT) This section uses the translation method identical with ISO 8319-1.1996 "orthopedic tools twist fittings - Part 1. socket head cap screws with a wrench hand". This part of ISO 8319-1.1996 technical differences are as follows: Appendix A to add a reference to the ISO 9585. Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This part is proposed by the China Food and Drug Administration. This part of the National Surgical implants and orthopedic instruments Standardization Technical Committee materials and orthopedic implants Technical Committee (SAC/TC110/SC1) centralized. This section is drafted. Tianjin Medical Device Quality Supervision and Inspection Center, the State Food and Drug Administration Medical Device Review Evaluation Center, Changzhou City, Kang Hui Medical Devices Co., Ltd. The main drafters of this section. Li Nan, King Ming, Ma bamboo, Liu Bin, Liu Yinghui, Yin Zhuo, Bao Yifu.

Various screw wrench basic requirements are as follows: Working end

--- screw wrench should be able to accurately fit the screw nail head;

--- Material for the manufacture of screw wrench shall meet all clinical requirements;

--- Screw wrench should be of sufficient strength; This part of ISO 8319 is intended to screw wrench design without affecting the properties of the premise to ensure that the above requirements can be achieved. Orthopedic tools twist fittings Part 1. socket head cap screws with a wrench

1 Scope

YY/T 0957.1 standardises the hexagon socket key used to drive orthopaedic screws, the most common drive interface in trauma and spinal implant systems. It is Part 1 of the Chinese series on orthopaedic instrument drive connections, with Part 2 covering slotted and cross recess drivers. The dimensions and tolerances it fixes are what determine whether the key engages fully, transmits the torque a locking screw needs, and comes out again without rounding the socket, which in a surgical setting is the difference between a routine step and an unplanned revision of technique. For a manufacturer of orthopaedic instrumentation or implant screws for the Chinese market, this is the governing dimensional standard for the interface.

YY/T 0957 provisions of this part of the working end wrench for screwed into or out of the surgical implant metal bone screws with a hex of Dimensions, tolerances, mechanical properties and performance requirements. Has a working end of this Part apply to screw wrench in line with ISO 5835 With screws.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 230.1 metallic materials - Rockwell hardness test - Part 1. Test methods (A, B, C, D, E, F, G, H, K, N, T standard Feet) ( GB/T 230.1-2009, ISO 6508-1.2005, MOD)

YY/T 0294.1 surgical instrument metallic materials - Part 1. Stainless steel ( YY/T 0294.1-2005, ISO 7153-1.1991, MOD)

YY/T 0605.5 surgical implants of metallic materials - Part 5. Wrought cobalt - chromium - tungsten - nickel alloy ( YY/T 0605.5-2007, ISO 5832-5.2005, IDT)

ISO 5835 Hexagon drive surgical implants under the spherical surface of asymmetrical thread connecting metal bone screw size (Implantsfor surgery-Metalbonescrewswithhexagonaldriveconnection, sphericalunder-surfaceofhead, asymmetrical thread-Dimensions)

3 Dimensions and tolerances

Dimensions and tolerances shall comply with Figure 1 and Table 1 provisions. Explanation. e

--- diagonal diameter; s

--- on the edge width; l

--- Hexagon length portion.

1 screw wrench size label

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

Normative references

ISO 6508 · YY/T 0294.1-2005 · ISO 7153 · YY/T 0605.5-2007 · ISO 5832 · ISO 5835

How to Buy YY/T 0957.1-2014

  1. 1Add to cart. Click the "Buy YY/T 0957.1-2014" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0957.1-2014

$150.00

$130.00for partners