Scope
YY/T 0911-2014 is the English-translated version of 牙科学 聚合物基代型材料.
YY/T 0911-2014 is the Chinese pharmaceutical industry standard for the polymer-based die materials used in dentistry, the materials whose main component is a polymer matrix and which serve in the dental laboratory to make the die on which a restoration is built.
It sets the requirements for their composition, their performance and their use and for the packaging, the labelling and the testing, covering the setting behaviour, the dimensional accuracy and stability, the hardness and the abrasion resistance and the detail reproduction. Issued on 17 June 2014, it has applied since 1 July 2015.
Found what you need?
Document preview — YY/T 0911-2014
National Standard of the People's Republic of China
- ICS
- 11.060.10
- Classification
- C 33
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Requirements
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses the translation method identical with ISO 14233:2003 "Dentistry polymer-based die material" This standard and ISO 14233:2003 is the main differences.
--- Delete "ISO Introduction." Correspondence between the consistency of the standards of international documents and normative references of the following documents.
--- GB/T 4340.1-2009 metal materials - Vickers hardness test - Part 1. Test method (ISO 6507-1:2005, MOD);
--- GB/T 7408-2005 data elements and interchange formats - Information interchange dates and times (ISO 8601:2004, IDT);
--- YY 0493-2011 dentistry elastomeric impression materials (ISO 4823:2000, IDT).
1 Scope
This standard composition, performance, use, packaging, labeling and testing requirements applied to the polymer-based dental materials carried out on behalf of Provisions.
This standard applies to substituting materials with a polymer matrix as the main component. Polymer-based die material mainly used for dental laboratories from Stamp reproduction of fixed production activities or repair model body (mold).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
ISO 4823 Dentistry elastomeric impression material (Dentistry-Elastomericimpressionmaterials)
ISO 6507-1 Vickers hardness testing of metallic materials - Part 1. Test method (Metalicmaterials-Vickers hardnesstest-Part 1. Testmethod)
ISO 8601 Data elements and interchange formats - Information interchange the date and time notation (Dataelementsandinterchange formats-Informationinterchange-Representationofdatesandtimes)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1 Polymer-based die material
It refers mainly comprising a metal, metal oxide and (or) an inorganic filler in an epoxy resin, a polyurethane or acrylic resin (particularly an epoxy resin And polyurethane) type material.
4 Requirements
4.1 Composition
Each component polymer-based die material should be no impurities, no signs of deterioration. Follow the manufacturer's instructions, the material should be able to form a pot The intended use solid purpose. Tested in accordance with 6.2.
4.2 Hours
Polymer-based materials on behalf of working time in minutes, not less than the manufacturer claims a time. According to the manufacturer's working time When testing, should meet the requirements of 4.4. Tested in accordance with the provisions of 6.3.
4.3 Curing time
The manufacturer claims is reached curing time, polymer-based materials on behalf of the Vickers hardness of not less than 6HV0.2.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
ISO 4823 · ISO 6507-1 · ISO 8601
Similar standards
How to Download YY/T 0911-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field
YY/T 0492-2026 — Implantable leads
Secure payment via Stripe
Payments accepted
YY/T 0911-2014
$185.00