YY/T 0807-2010Standard guide for measuring securement of balloon expandable vascular stent mounted on delivery system (English PDF)
预装在输送系统上的球囊扩张血管支架稳固性能标准测试方法
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0807-2010 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
December 27, 2010
Implementation date
June 1, 2012
Scope
YY/T 0807-2010 is the English-translated version of 预装在输送系统上的球囊扩张血管支架稳固性能标准测试方法.
YY/T 0807-2010 is the Chinese pharmaceutical industry standard that guides the measurement of the securement of a balloon expandable vascular stent mounted on its delivery system, that is of the stent as preloaded and not yet deployed.
It gives guidance on the specimen handling, on the design of the test and of its end point and on the testing itself, so that the force needed to dislodge the stent from the balloon can be determined and compared. Issued on 27 December 2010, it applies from 1 June 2012.
Found what you need?
Document preview — YY/T 0807-2010
National Standard of the People's Republic of China
- ICS
- 11.040.40
- Classification
- C 35
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Significance and Use
- 5 4 clinical status
- 6 Detection
- 7 instruments and procedures Example
- 8 9 Test Report
- Appendix A (normative) theory and examples
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard reference method using redrafted ASTM F2394-2007 "pre-installed on the delivery system balloon expandable stent stability Standard Test Method can "establishment.
This standard is a technical difference ASTM F2394-2007 deleted Chapter 9 "key words." Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
1 Scope
This standard is already pre-installed, but not released balloon expandable stent delivery system in the stent delivery system stability performance testing Processing, testing, and end of the test design and development guidance. This standard is intended to help researchers already preinstalled without sheath balloon support Frame delivery system design, research and in vitro characterization.
This standard applies to the laboratory to determine the move or remove pre-installed on a balloon delivery system needed to expand stent shear. The standard Motion offers several options when test rack solid performance to consider. These options include pre-test process, probable stent stability To test and associated test endpoints. It gives an example of a measuring instrument in 7.1.
This standard only applies to the characterization of in vitro tests. Test pretreatment method, stable performance test type (e.g. bracket fixing method) and tested The end of the selection may partly affect the stability of the measured performance levels and product design/processing differences. The characteristics of the body may Differ from the results in vitro.
This standard does not cover all possible test before treatment, the stent solid performance testing and end of the test, is intended to provide a starting point, thereby Stent selection and solid performance testing options.
This standard does not specify the method of mounting bracket on the conveyor system.
This standard does not attempt to all the security issues involved elaborate, even those safety issues associated with their use. establish Appropriate safety and health practices and suitability before applying clear administrative limit, this is the standard user's own responsibility.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
YY 0285.1 Disposable Sterile intravascular catheters - Part 1. General requirements (YY 0285.1-2004, ISO 10555-1. 1995, IDT)
Particular requirements for YY/T 0663-2008 active surgical implants cardiac and vascular implants - Particular requirements for arterial stents (EN 14299:2004, IDT) ASTM E1169 Robustness Test Guidelines (Standardpracticeforconductingruggednesstests)
Standard Guide for Application of statistical procedures (Standardguideforstatistical ASTM E1488 test method development and implementation procedurestouseindevelopingandapplyingtestmethods)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1 Balloon-expandable stent baloonexpandablestent
Expandable stent at the treatment site by a balloon catheter. Scaffold due to balloon dilatation and plastic deformation, after the balloon is evacuated branched
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 0807-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY 0285.1-1999 — Sterile, single-use intravascular catheters - Part 1: General requirements
YY 0285.1-2004 — Sterile, single-use intravascular catheters - Part 1: General requirements
YY 0285.1-2017 — Intravascular catheters—Sterile and single-use catheters - Part 1: General requirements