YY/T 0802.1-2024Processing of medical devive - Information to be provided by the medical device manufacturer - Part 1: Critical and semi-critical medical devices (English PDF)
This is a limited preview
Buy now to download the full PDF (21 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0802.1-2024 in 30 minutes.
Issued by
National Medical Products Administration
Level / Type
National · Recommended
Issue date
September 29, 2024
Implementation date
October 15, 2025
Scope
YY/T 0802.1-2024 (Processing of medical devive - Information to be provided by the medical device manufacturer - Part 1: Critical and semi-critical medical devices) is available as an English-translated PDF.
YY/T 0802.1-2024 — This document specifies the requirements for information to be provided by medical device manufacturers regarding the processing of critical and semi-critical medical devices (i.e., medical devices that enter normally sterile areas of the human body, or medical devices that contact mucous membranes or non-intact skin) or medical devices that are to be sterilized.
This document applies to information on the processing prior to the use or reuse of medical devices.
This document does not define processing instructions, but rather specifies requirements for medical device manufacturers to provide detailed processing instructions that include the following applicable steps. a) immediate on-site processing after use; b) preparation before cleaning; c) cleaning; d) disinfection; e) drying; f) inspection and maintenance; g) packaging; h) sterilization; i) storage; j) Transportation.
This document does not apply to the processing of the following items. -- Non-critical medical devices that are not intended to be sterilized; A documented procedure for obtaining, recording and interpreting the results necessary to determine that a process consistently produces product conforming to predetermined specifications.
Found what you need?
Document preview — YY/T 0802.1-2024
National Standard of the People's Republic of China
- ICS
- 11.080.01
Issued by: National Medical Products Administration
Contents
- Foreword...3
- Introduction...5
- 1 Scope...7
- 2 Normative references...8
- 3 Terms and definitions...8
- 4 Validation of the processing in information...11
- 5 Risk analysis...11
- 6 Information provided by medical device manufacturers...12
- 7 Information expression...20
- Appendix A (Informative) Common processing methods...21
Foreword
This document was drafted in accordance with the provisions of GB/T 1.1-2020
Directives for standardization - Part 1.Rules for the structure and drafting of
standardizing documents.
This document is part 1 of YY/T 0802 Processing of medical device - Information to be
provided by the medical device manufacturer. YY/T 0802 has been published in the
following parts.
-- Part 1.Critical and semi-critical medical devices;
-- Part 2.Non-critical medical devices.
This document replaces YY/T 0802-2020 Processing of medical devices - Information
to be provided by the medical device manufacturer. Compared with YY/T 0802-2020,
in addition to structural adjustments and editorial changes, the main technical changes
are as follows.
-- The scope has been changed (see Chapter 1; see Chapter 1 of the 2020 edition);
-- The term and definition of "medical device manufacturer" have been changed
(see 3.5; see 3.5 of the 2020 edition);
-- The content of the processing instructions has been changed (see 6.2; see 6.2 of
the 2020 edition);
-- The content of immediate on-site treatment after use has been changed (see 6.4;
see 6.4 of the 2020 edition);
This document is modified in relation to ISO 17664-1.2021 Processing of health care
products - Information to be provided by the medical device manufacturer for the
processing of medical devices - Part 1.Critical and semi-critical medical devices.
The technical differences between this document and ISO 17664-1.2021 and their
reasons are as follows.
-- The term and definition "3.5 medical device" have been deleted to coordinate
with regulations.
The following editorial changes were made to this document.
-- The note to the term and definition of "3.5 medical device manufacturer" has
been deleted.
Processing of medical device - Information to be provided by
the medical device manufacturer - Part 1.Critical and semi-
critical medical devices
1 Scope
This document specifies the requirements for information to be provided by medical
device manufacturers regarding the processing of critical and semi-critical medical
devices (i.e., medical devices that enter normally sterile areas of the human body, or
medical devices that contact mucous membranes or non-intact skin) or medical devices
that are to be sterilized.
This document applies to information on the processing prior to the use or reuse of
medical devices.
This document does not define processing instructions, but rather specifies
requirements for medical device manufacturers to provide detailed processing
instructions that include the following applicable steps.
a) immediate on-site processing after use;
b) preparation before cleaning;
c) cleaning;
d) disinfection;
e) drying;
f) inspection and maintenance;
g) packaging;
h) sterilization;
i) storage;
j) Transportation.
This document does not apply to the processing of the following items.
-- Non-critical medical devices that are not intended to be sterilized;
A documented procedure for obtaining, recording and interpreting the results necessary
to determine that a process consistently produces product conforming to predetermined
specifications.
3.20 verification
To confirm by providing objective evidence that specified requirements have been met.
[Source. ISO 9000.2015, 3.8.13, modified]
3.21 washer-disinfectors; WD
Equipment that is expected to clean and disinfect items.
[Source. ISO 11139.2018, 3.319, modified]
4 Validation of the processing in information
4.1 The medical device manufacturer shall validate each processing step in the
information provided with the medical device. Validation shall confirm that each
processing step is appropriate.
4.2 The medical device manufacturer shall provide objective evidence that the
validation of processing has been performed to demonstrate that the medical device will
be clean, disinfected and/or sterilized after processing in the specified sequence.
NOTE 1.In addition to the manufacturer's obligation to prove the validity of the information provided,
the relevant management department can also require the processor to verify the final validity of the
processing.
NOTE 2.The relevant management department may allow or require the use of other methods for
processing. In this case, it is usually necessary for the processor to confirm the effectiveness of the
processing method.
4.3 If different medical devices provided by the manufacturer have common properties,
their validation can be carried out as a product family. If this approach is adopted, the
medical device manufacturer shall confirm the commonalities between the different
medical devices and consider the most unfavorable state of the product family in the
validation.
NOTE. See C.1 in Appendix C.
5 Risk analysis
Medical device manufacturers shall conduct risk analysis to determine the content and
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.
Referenced standards
How to Download YY/T 0802.1-2024
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0802.2-2024 — Processing of medical device - Information to be provided by the medical device manufacturer - Part 2: Non-critical medical devices
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field
Secure payment via Stripe
Payments accepted
YY/T 0802.1-2024
$360.00