YY/T 0771.1-2020Medical devices utilizing animal tissues and their derivatives - Part 1: Application of risk management (English PDF)
动物源医疗器械 第1部分:风险管理应用
This is a limited preview
Buy now to download the full PDF (24 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0771.1-2020 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
September 1, 2025
Implementation date
April 1, 2021
Scope
YY/T 0771.1-2020 is the English-translated version of 动物源医疗器械 第1部分:风险管理应用.
YY/T 0771.1-2020 is the Chinese standard "Medical devices utilizing animal tissues and their derivatives - Part 1: Application of risk management".
Its scope clause reads: This part of YY/T 0771 specifies the identification and use of animal-derived materials (inactive or rendered inactive) for medical devices Equipment-related hazards (sources) and hazardous situations, the estimation, evaluation and control of the resulting risks, and procedures for monitoring the effectiveness of these controls (Combined with YY/T 0316-2016).
This section applies to medical devices manufactured from animal-derived materials (inactive or rendered inactive), excluding in vitro diagnostic medicine Therapeutic equipment.
This section does not apply to medical devices that use human tissue. This section does not specify a quality management system for the control of the entire production stage of medical devices.
In addition, taking into account the residual risk defined in YY/T 0316-2016 and weighing the expected medical comparison with other alternatives Treatment benefit, this section gives the judgment process of the acceptability of residual risk, as well as medical devices manufactured using animal tissue or its derivatives Requirements and guidelines for risk management of hazards (sources) .These hazards (sources) include. a) Bacterial, mold or yeast contamination; b) virus contamination; c) Contaminated Spongiform Spongiform Encephalopathy (TSE) factors; d) Unwanted pyrogenic, immunological or toxicological reactions caused by the material.
Similar principles apply to parasites or other unclassified pathogens. Note 1. The operation of a comprehensive quality management system during the production process is not a requirement of this part.
See the quality management system for the control of all stages of medical device production or reprocessing For the standard, see YY/T 0287. Note 2. Refer to Appendix A for application guidance in this section. Its clauses include terms and definitions.
Found what you need?
Document preview — YY/T 0771.1-2020
National Standard of the People's Republic of China
- ICS
- 11.100.20
- Classification
- C30
Issued by: National Medical Products Administration
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Risk management process
- Appendix A (informative appendix) Application guide for this part
- Appendix C (Normative Appendix) Particular Requirements for Risk Management of Specific Animal Material TSE Factors
- Appendix D (Informative Appendix) TSE Risk Management Related Information
1 Scope
This part of YY/T 0771 specifies the identification and use of animal-derived materials (inactive or rendered inactive) for medical devices
Equipment-related hazards (sources) and hazardous situations, the estimation, evaluation and control of the resulting risks, and procedures for monitoring the effectiveness of these controls (Combined with YY/T 0316-2016).
This section applies to medical devices manufactured from animal-derived materials (inactive or rendered inactive), excluding in vitro diagnostic medicine
Therapeutic equipment.
This section does not apply to medical devices that use human tissue.
This section does not specify a quality management system for the control of the entire production stage of medical devices.
In addition, taking into account the residual risk defined in YY/T 0316-2016 and weighing the expected medical comparison with other alternatives
Treatment benefit, this section gives the judgment process of the acceptability of residual risk, as well as medical devices manufactured using animal tissue or its derivatives
Requirements and guidelines for risk management of hazards (sources) .These hazards (sources) include.
a) Bacterial, mold or yeast contamination;
b) virus contamination;
c) Contaminated Spongiform Spongiform Encephalopathy (TSE) factors;
d) Unwanted pyrogenic, immunological or toxicological reactions caused by the material.
Similar principles apply to parasites or other unclassified pathogens.
Note 1. The operation of a comprehensive quality management system during the production process is not a requirement of this part. See the quality management system for the control of all stages of medical device production or reprocessing
For the standard, see YY/T 0287.
Note 2. Refer to Appendix A for application guidance in this section.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this article
Pieces. For the cited documents without date, the latest version (including all amendments) applies to this document.
GB/T 16886.1 Biological evaluation of medical devices Part 1. Evaluation and testing in the process of risk management (GB/T 16886.1-
2011, ISO 10993-1..2009, IDT)
YY/T 0316-2016 Application of medical device risk management to medical devices (ISO 14971..2007, IDT)
YY/T 0771.2-2020 Medical devices of animal origin Part 2. Control of source, collection and disposal (ISO 22442-2..2015,
MOD)
YY/T 0771.3 Medical Devices of Animal Origin Part 3. Virus and Transmissible Spongiform Encephalopathy (TSE) Factor Elimination and Inactivation
Confirmation (YY/T 0771.3-2009, ISO 22442-3..2007, IDT)
3 Terms and definitions
The terms and definitions defined in YY/T 0316-2016 and the following apply to this document.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 16886.1Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
- YY/T 0316-2016Medical devices-Application of risk management to medical devices
- YY/T 0771.2-2020Medical devices utilizing animal tissues and their derivatives - Part 2: Controls on sourcing, collection and handling
- YY/T 0771.3-2009Medical devices utilizing animal tissues and their derivatives - Part 3: Validation of the elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents
ISO 10993 · ISO 14971 · ISO 22442
Cited by
- GB/T 45351-2025Manufacture of cell-based medical devices - Control of microbial risks during processing
- YY/T 1950-2024Tissue engineering medical device - Silk fibroin
- YY/T 1876-2023Tissue engineered medical products - Quantification of remnant DNA in animal-derived biomaterials - Fluorescent staining method
- YY/T 0988.3-2021Coatings of surgical implants - Part 3: Mussel adhesive proteins
- YY/T 1788-2021Implants for surgery-General requirements for animal-derived patch products
- YY/T 0771.2-2020Medical devices utilizing animal tissues and their derivatives - Part 2: Controls on sourcing, collection and handling
How to Download YY/T 0771.1-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16886.1-2022 — Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
GB/T 16886.10-2024 — Biological evaluation of medical devices - Part 10: Tests for skin sensitization
GB/T 16886.11-2021 — Biological evaluation of medical devices - Part 11: Tests for systemic toxicity
Secure payment via Stripe
Payments accepted
YY/T 0771.1-2020
$360.00