YY/T 0725-2009Dental equipment—Connections for supply and waste lines (English PDF)
牙科设备 给排管路的连接
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0725-2009 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
June 16, 2009
Implementation date
December 1, 2010
Scope
YY/T 0725-2009 is the English-translated version of 牙科设备 给排管路的连接.
YY/T 0725-2009 is the Chinese pharmaceutical industry standard that fixes the requirements for the connections of the supply and waste lines of dental equipment, of the dental unit and of the instruments and devices joined to them.
It covers the layout of the pipework and the interconnection between the lines, and it applies to the water and waste water lines and to the suction line and their relative positions, setting out the dimensions of the connections and the way each line is identified. Issued on 16 June 2009, it has applied since 1 December 2010.
Found what you need?
Document preview — YY/T 0725-2009
National Standard of the People's Republic of China
- ICS
- 11.060.20
- Classification
- C 33
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions GB/T
- 4 Requirements
Foreword
All aspects of this standard are recommended.
Introduction
In the dental unit with a treatment center, people continue to improve its design and equipment configurations to meet the requirements of modern dentistry. different Treatment machine manufacturer and model, its connection size and relative position of the facility are also different.
Equipment selection, especially in large installations of equipment selection, in order to determine the layout of the pipeline may have to be good at an early stage of construction The building was not in accordance with the appropriate equipment needed to choose. When after installing a replacement device, often to transform the main line. By Facilities layout standardization, to avoid the appearance of these difficulties, and to ensure that the pipeline contractor for proper facility requirements.
This standard is not intended to specify equipment should be within the scope of the use of dental surgeries, but the mutual position of the device will make provision. Dental equipment is connected to the exhaust pipe
1 Scope
This standard specifies the dental equipment, dental unit, instruments and devices used to connect the discharge pipe layout requirements, including constructing the pipeline And inter-line interconnection requirements. This standard also provides water, wastewater, and the relative position attracted (vacuum) supply line applies, in Heart and minimum size, and the size of the circuit and the compressed air line for dental services and facilities near the designated area.
Requirements of this standard apply to dental unit and dental treatment centers require all kinds.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 9937.4-2005 Dental Terminology - Part 4. Dental equipment (ISO 1942-4:1999, IDT)
3 Terms and definitions GB/T
9937.4 and established the following terms and definitions apply to this standard.
3.1 Dental treatment centre
Appurtenances dental composition function items, such as the dental unit, dental patient chairs and dental equipment and instruments interconnected Composition, treatment can provide a functional environment for dental care.
4 Requirements
4.1 connection configuration should meet the requirements of Figure 1. Given circuit, compressed air connection area size, maximum.
Aperture given minimum. Which provides free space size diameter pipes and hoses requirements.
No required size hole can be placed anywhere within the region in connection.
If there are other requirements for gas pipe, the gas pipe should not be placed in a predetermined region of FIG.
This standard does not specify the joint position that has other uses, the manufacturer shall make provision.
4.2 Measurement of the dimensions
Dimensions specified in Figure 1, you should use a suitable measuring device to measure general.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 9937.4-2005
Similar standards
How to Download YY/T 0725-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field
YY/T 0492-2026 — Implantable leads
Secure payment via Stripe
Payments accepted
YY/T 0725-2009
$105.00