Valid

YY/T 0684-2008Neurosurgical implants - Marking and packaging of implantable neural stimulators (English PDF)

神经外科植入物 植入式神经刺激器的标识和包装

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0684-2008 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

October 17, 2008

Implementation date

January 1, 2010

Scope

YY/T 0684-2008 is the English-translated version of 神经外科植入物 植入式神经刺激器的标识和包装.

YY/T 0684-2008 adopts ISO 10310:1995 unchanged and covers the marking, labelling, packaging and accompanying documents of implantable neural stimulators acting on the brain, spinal cord, peripheral nerves and adjacent tissue.

Its definitions separate the parts of such a system: the implantable pulse generator with its own power source, the implantable RF receiver powered from outside, the RF transmitter, the antenna and its cable, and the programmer.

Accessories that are implanted or used externally, such as the external controllers that start or adjust the stimulator, are covered too. The standard does not set indications or contraindications, nor test methods or operating ranges for the variable parameters.

What it does require is the information clinicians need in the documents supplied with each pulse generator, RF receiver or RF transmitter. Issued on 17 October 2008, it has applied since 1 January 2010.

Found what you need?

Document preview — YY/T 0684-2008

National Standard of the People's Republic of China

ICS
11.040.40
Classification
C 35

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Terms and definitions

Foreword

This standard is identical with ISO 10310:1995 "Neurosurgical implants implantable neurostimulator labeling and packaging." Appendix A of this standard is an informative annex.

1 Scope

This standard specifies the identifier for stimulating the nervous system (brain, spinal cord, peripheral nerves and adjacent tissue) implantable nerve stimulator, standard Asked to sign, packaging and accompanying documents.

This standard also covers accessories implantable or external access, including external control is used to start or adjust the neurostimulator System and programmer.

This standard does not apply the provisions of implantable nerve stimulator indications or contraindications; testing or normal operation variable parameters unspecified range. But the requirements of this standard shall contain such information related to a patient when used in the treatment of each clinician implantable pulse generator Accompanying documentation generator, implanted RF receiver or RF transmitter in.

2 Terms and definitions

The following terms and definitions apply to this standard.

2.1 Implantable neural stimulator

Electrical stimulation of the nervous system (brain, spinal cord, peripheral nerves and adjacent tissue) of equipment, including a pulse generator and its function and control.

Necessary for implantable or external access to all auxiliary components of the human body.

2.2 Implantable pulse generator

With its own power supply implantable devices, which can generate electrical pulses in a continuous or intermittent manner to stimulate the nervous system.

2.3 Programmer

External access equipment, used to control or adjust the parameters neurostimulator system.

2.4 Implantable RF receiver

Implantable devices without their own power supply, which is a radio frequency (RF) transmitter and antenna rely emitted energy to produce pulses stimulate nerve system.

2.5 RF transmitter

Portable devices, including implantable RF receiver for controlling the pulse generator and modulator circuit.

Note 1. The transmitter typically includes a power supply, an antenna may further include a user adjustable controller and internal use controllers.

2.6 Antenna

To enable the implantable receiver RF transmit coil.

Note 2. The antennas are typically used on the skin or placed close to the skin, close to the implantable RF receiver position.

2.7 Antenna cable

It used to connect the transmitter and antenna, and external body insulated wire or wires, one or both ends with or without integral connector.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download YY/T 0684-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0684-2008

$115.00