YY/T 0583.2-2016Chest drainage systems for single use - Part 2: Type of dry seal valve (English PDF)
一次性使用胸腔引流装置 第2部分:干封阀式
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0583.2-2016 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
March 23, 2016
Implementation date
January 1, 2017
Scope
YY/T 0583.2-2016 is the English-translated version of 一次性使用胸腔引流装置 第2部分:干封阀式.
YY/T 0583.2-2016 is the Chinese pharmaceutical industry standard for the sterile single-use dry seal chest drainage system, which can drain by gravity or be connected to a suction source.
It is the second part of the YY/T 0583 series and sets the requirements for the device: the dry seal and the suction control, the fluid chamber and its graduations, the connectors and the drainage tube, the tightness and the automatic pressure relief, the materials and their biological evaluation and sterility.
It does not cover the chest catheter itself nor autotransfusion systems. Issued on 23 March 2016, it has applied since 1 January 2017.
Found what you need?
Document preview — YY/T 0583.2-2016
National Standard of the People's Republic of China
- ICS
- 11.040.40
- Classification
- C 45
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative reference documents
- 3 Terms and definitions YY/T 0583.1-2015 and the following
- 4 Physical requirements
Foreword
YY/T 0583 "One-time use of chest drainage device" is divided into two parts.
- Part 1. Watertight;
- Part 2. Dry sealing valve type.
Other types of drainage devices will be developed in other parts of YY/T 0583. This part is part 2 of YY/T 0583.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
Introduction
YY/T 0583 The one-time use of the thoracic drainage device specified in this section is mainly applicable to the gas caused by various causes Chest, pleural effusion and patients who need to undergo closed drainage after surgery. After thoracic drainage in patients with thoracic cavity residual body, effusion "single To the drainage ", and can accurately measure the drainage fluid is the most basic requirements of clinical drainage. Dry sealing valve type chest drainage device is characterized by a one-way "Dry seal valve" to achieve the residual gas, the one-way drainage of the effusion. Because of its working principle does not depend on the water seal, even in the device in a dumping state It will not lose its anti-reflux. The disadvantage is that it can not be like a water-tight pleural drainage device, so that doctors can observe the water in the water chamber Column volatility state to determine the patient's treatment.
Chest drainage is usually by the patient's own breathing and cough in the natural formation of the pleural cavity pressure to achieve continuous drainage. Clinically for the sake of mention High drainage effect, often with external negative pressure source to help drainage (active drainage or suction drainage). This section deals with the drainage device Attractive control is a design type used to regulate external negative pressure. Clinical can also be used in other ways to regulate the pressure.
Appendix E gives the working principle of the device in the form of an informative appendix.
Dry sealing valve type chest drainage device and water-sealed chest drainage device, the pressure unit also uses cm water column, its purpose is to facilitate clinical Observation and use.
1 Scope
YY/T 0583 this part of the provisions of the sterile supply of dry sealed valve disposable thoracic drainage device (referred to as drainage device)
Claim. The device can be gravity drainage, but also with the negative pressure suction system to achieve suction to attract.
The thoracic drainage catheter inserted into the thoracic cavity of the patient and the autologous blood transfusion system of the thoracic drainage device with autologous blood transfusion system are not required Are included in this section.
2 Normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 19633.1-2015 Final sterilization of medical device packaging - Part 1. Materials, sterile barrier systems and packaging systems Claim Disposable use of thoracic drainage devices - Part 1. Water - sealed type YY/T 0583.1-2015
YY/T 0615.1 Requirements for "sterile" medical devices - Part 1. Requirements for final sterilization of medical devices
3 Terms and definitions YY/T 0583.1-2015 and the following
terms and definitions apply to this document.
3.1 Negative pressure status display
The drainage device can show the presence of negative pressure in the chamber.
3.2 Dry sealal (one-way valve) drysealvalve (one-wayvalve)
The drainage device may achieve a component that allows the patient to expel the gas during exhalation and to close the passage of the atmosphere with the patient & apos; s chest during inspiration.
3.3 High negative pressure automatic relief valve
When the negative pressure of the fluid chamber reaches a certain value, it can automatically release the safety protection module.
4 Physical requirements
4.1 General
In addition to the drainage device should be consistent with YY/T 0583.1-2015 in 5.1,5.2,5.3.2,5.6,5.8,5.9,5.10,5.12,5.13,5.14 And 5.15, the following physical requirements shall also be met.
4.2 Drainage nozzle size
The length of the drain connection shall be not less than 900 mm and the pipe at the connection with the drainage device shall be of anti-kinking measure and shall be provided with a drainage duct
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 19633.1-2015Packaging for terminally sterilized medical devices - Part 1: Requirements for materials, sterile barrier systems and packaging systems
- YY/T 0615.1Requirements for medical devices to be designated STERILE - Part 1: Requirements for terminally sterilized medical devices
YY/T 0583
Similar standards
How to Download YY/T 0583.2-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0583.1-2015 — Chest drainage systems for single use - Part 1: Type of water-seal
YY/T 0615.1-2007 — Requirements for medical devices to be designated STERILE - Part 1: Requirements for terminally sterilized medical devices