Valid

YY/T 0245-2008General specifications for stapler (English PDF)

吻(缝)合器 通用技术条件

Preview PDF

This is a limited preview

Buy now to download the full PDF (18 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0245-2008 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

April 25, 2008

Implementation date

December 1, 2009

Scope

YY/T 0245-2008 is the English-translated version of 吻(缝)合器 通用技术条件.

YY/T 0245-2008 is the Chinese pharmaceutical industry standard giving the general specifications for surgical staplers, both reusable and disposable, used for circular resection and anastomosis and for closing a mucosal or stump incision.

It sets out the classification, types and basic sizes, the requirements, including the hardness of the main parts measured by Rockwell or Vickers methods and the pressure-endurance indicators, the test methods, the inspection rules with sampling under GB/T 2828.1 and GB/T 2829, and the marking, instruction manual, packaging, transport and storage.

Normative annexes give the test methods for suture pressure and for peel strength. It replaces YY/T 0245.1-1997, extending it to disposable staplers. Issued on 25 April 2008, it has applied since 1 December 2009.

Found what you need?

Document preview — YY/T 0245-2008

National Standard of the People's Republic of China

Replacing
YY/T 0245.1-1997

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Classification and type5
  • 4 Requirements5
  • 5 Test methods7
  • 6 Inspection rules9
  • 7 Marks, instruction manual11
  • 8 Packaging, transport, storage14
  • Annex A (normative) Test method for suture pressure16
  • Annex B (normative) Test method for peel strength18

Foreword

This Standard replaces YY/T 0245.1-1997 "Specifications for suture forceps".

The main differences between this Standard and YY/T 0245.1-1997 are as follows.

- expanded product's application scope in this Standard, that is, it is applicable to reusable stapler and disposable stapler;

- rearranged the requirements in YY/T 0245.1-1997 according to the characteristics, which makes the content more distinct in level;

- directly specified the requirements for hardness of main parts of stapler in this Standard;

- directly listed the pressure-endurance indicators for stapler in this Standard, which shall be assessed uniformly;

- added Annex B "Test method for peel strength". Annex A and Annex B of this Standard are normative.

1 Scope

This Standard specifies classification and type, requirements, test methods, inspection rules, marks, instruction manual, packaging, transport and storage for stapler.

This Standard is applicable to reusable stapler and disposable stapler. This product is used for the stapler whose components are mounted on the stapler as round tubular incision as well as circular resection and anastomosis of the upper mucosa or stump incision closed suture.

2 Normative references

The provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies.

GB/T 230.1, Metallic materials - Rockwell hardness test - Part 1: Test method (GB/T 230.1-2004, ISO 6508-1:1999, MOD)

GB/T 1220, Stainless steel bars

GB/T 2828.1, Sampling procedures for inspection by attributes - Part 1. Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection (GB/T 2828.1-2003, ISO 2859-1:1999, IDT)

GB/T 2829, Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability)

GB/T 4340.1, Metallic materials - Vickers hardness test - Part 1: Test method (GB/T 4340.1-1999, eqv ISO 6507-1:1997)

GB 9969.1, General principles for preparation of instructions for use of industrial products

3 Classification and type

3.1 Type and basic size of stapler shall comply with the provisions in corresponding product standards.

4 Requirements

4.1 Material of stapler nail

Stapler nail may use TA1, TA2 materials specified in GB/T 13810 or Ta1 tantalum wire. The chemical composition of tantalum wire shall comply with the provisions of Table 2.

4.2 Use performance

4.2.1 The components and the body frame of stapler shall be assembled and disassembled smoothly. Each moving part shall be easy to push, without jamming or looseness. The components shall be firm when they are loaded into the body. Stapler nail shall not fall off.

4.3 Hardness

The parts made of 20Cr13 material must be heat-treated. Its hardness is 40HRC ~ 48HRC. The hardness of the cutting blade shall not be lower than 377HV0.2.

4.4 Surface roughness

The value of external surface roughness parameter Ra of reusable stapler shall not exceed. 0.4µm for the one with brightness, 0.8µm for the one without brightness.

4.7 Appearance

The shape of stapler shall be flat, smooth, without sharp edges, burrs and cracks. The scale value or mark on the stapler body shall be clear.

4.8 Size

The size of stapler shall comply with the provisions of product standard. The error between the scale value and the head end shall be no more than 0.2mm.

4.9 Sterilization

4.10 Biological evaluation

4.10.1 The cytotoxicity of the components and disposable body shall be no more than level 1.

5 Test methods

5.1 Material inspection

The chemical composition analysis of pure titanium material shall be performed according to the method specified in GB/T 13810. The chemical composition analysis of tantalum wire material shall be performed according to the method specified in GB/T 15076.1~15076.15, in accordance with the provisions of 4.1.

5.2 Use performance

5.3 Hardness

Perform according to the method specified in GB/T 230.1 or GB/T 4340.1.

Measure three points at the heat-treating surface. Take the arithmetic mean of each three points, in accordance with the provisions of 4.3.

5.4 Surface roughness

Use sample block comparison method or electrical measurement method. Use electrical measurement method for arbitration, in accordance with the provisions of 4.4.

5.5 Corrosion resistance performance

Perform according to the boiling water test method in YY/T 0149, in accordance with the provisions of 4.5.

5.8 Size

Use general or particular measuring tool to measure, in accordance with the provisions of 4.8.

5.9 Inspection of sterile and ethylene oxide residues

5.9.1 Randomly inspect 3 pieces from the same batch and perform according to the method specified in the pharmacopoeia, in accordance with the provisions of 4.9.1.

5.9.2 Perform the determination of ethylene oxide residue according to the method specified in GB/T 16886.7, in accordance with the provisions of 4.9.2.

5.10 Biological evaluation

5.10.1 Perform according to the method of direct contact test in 8.3 of GB/T 16886.5-2003, in accordance with the provisions of 4.10.1.

6 Inspection rules

6.4.2 Inspection items and sampling method of periodic inspection are in accordance with the provisions of Table 4. In any of the following cases, the biological evaluation specified in 4.10 shall be added (exemption can be made if it is not one of the following cases).

6.4.5 The qualified periodic inspection refers that periodic inspections of all test groups within this period are qualified; otherwise the periodic inspection shall be regarded as rejected.

6.1 Acceptance

Staplers shall be inspected by manufacturer technical inspection department. Only the qualified ones are submitted to purchaser for acceptance.

6.2 Inspection

Staplers must be submitted in batches for inspection. The inspection is divided into batch inspection (exit-factory inspection) and period inspection (type inspection).

6.3 Batch inspection

7 Marks, instruction manual

7.1 Marks

7.1.1 Each piece of stapler or component, according to the provisions of YY/T 1052, shall have the following marks.

7.1.2 On the box, there shall be the following marks.

7.1.3 On the inspection certificate, there shall be the following marks.

7.1.4 On the seal, there shall be the following marks.

7.2 Aseptic packaging mark

7.4 Instruction manual

7.4.1 The instruction manual shall contain the following information.

7.4.2 Aseptic packaging instruction manual shall contain the following information.

7.4.3 The preparation of instruction manual shall comply with the provisions of GB 9969.1.

8 Packaging, transport, storage

8.1 Packaging

8.2 Aseptic packaging

8.2.1 Disposal stapler has two packaging patterns. device (containing components) separate packaging and component separate packaging. The small packaging is the minimum packaging for one-time use. The packaging material is polyethylene terephthalate (PET). The packaging pattern is sealed packaging, which shall ensure product sterility until it is unsealed.

8.3 Packaging of special requirements

The packaging of special requirements is in accordance with the provisions of the order contract.

8.4 Transport

The requirements for packing and transport are in accordance with the provisions of the order contract. […]

8.5 Storage

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.

Referenced standards

Editions of YY/T 0245

EditionTitleRevisionStatus
YY/T 0245-2008General specifications for staplercurrent editionCurrent
YY/T 0245.1-1997General specifications for staplerprevious editionSuperseded

This page sells the current edition, YY/T 0245-2008. Earlier editions are listed for reference only.

How to Download YY/T 0245-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
18 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0245-2008

$95.00