YY 1650-2019X-ray based image-guided radiotherapy equipment - Performance characteristics and test methods (English PDF)

X射线图像引导放射治疗设备性能和试验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (13 pages)

Need quotation for your management?

Get a formal quotation for YY 1650-2019 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Mandatory

Issue date

May 31, 2019

Implementation date

December 1, 2020

Scope

YY 1650-2019 is the English-translated version of X射线图像引导放射治疗设备性能和试验方法.

YY 1650-2019 is the Chinese standard "X-ray based image-guided radiotherapy equipment - Performance characteristics and test methods". Its scope clause reads: This standard specifies the requirements and test methods for X-ray image guided radiotherapy (hereinafter referred to as X-IGRT) equipment.

This standard applies to electronic accelerators, light ion beam therapy equipment and X-IGRT equipment for radionuclide beam therapy equipment. Its clauses include terms and definitions.

Found what you need?

Document preview — YY 1650-2019

National Standard of the People's Republic of China

ICS
11.040.60
Classification
C43

Issued by: National Medical Products Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Requirements
  • 4.1 Random File
  • 4.2 X-IGRT equipment radiation field size
  • 4.3 Target guidance range of X-IGRT equipment
  • 4.4 Image quality of X-IGRT equipment
  • 4.5 imaging dose
  • 4.6 Accuracy of X-IGRT Position Correction Calculation
  • 4.7 Repeatability of X-IGRT Position Correction Calculation
  • 4.8 Influence of reference image layer thickness on X-IGRT position correction calculation
  • 4.9 Influence of reference image DRR algorithm on X-IGRT position correction calculation
  • 4.10 Effect of radiation quality on X-IGRT position correction calculation
  • 4.11 Influence of X-IGRT reconstruction algorithm on X-IGRT position correction calculation
  • 4.12 Effect of Image Registration Algorithm on X-IGRT Position Correction Calculation
  • 5 Test method
  • 5.1 Random File
  • 5.2 X-IGRT equipment radiation field size
  • 5.3 Target guidance range of X-IGRT equipment
  • 5.4 Image quality of X-IGRT equipment
  • 5.5 imaging dose
  • 5.6 Accuracy of X-IGRT Position Correction Calculation
  • 5.7 Repeatability of X-IGRT Position Correction Calculations
  • 5.8 Influence of reference image layer thickness on X-IGRT position correction calculation
  • 5.9 Influence of reference image DRR algorithm on X-IGRT placement correction calculation
  • 5.10 Effect of radiation quality on X-IGRT position correction calculation
  • 5.11 Effect of X-IGRT image reconstruction algorithm on X-IGRT placement correction calculation
  • 5.12 Effect of Image Registration Algorithm on X-IGRT Position Correction Calculation

1 Scope

This standard specifies the requirements and test methods for X-ray image guided radiotherapy (hereinafter referred to as X-IGRT) equipment.

This standard applies to electronic accelerators, light ion beam therapy equipment and X-IGRT equipment for radionuclide beam therapy equipment.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB 15213-2016 Medical electron accelerator performance and test methods

IEC 60601-2-68.2014 Medical electrical equipment - Part 2-68. Electron accelerators, light ion beam therapy equipment and radiation

Special requirements for basic safety and basic performance of X-ray image-guided radiotherapy equipment for use with sex nuclear beam therapy equipment

3 Terms and definitions

The following terms and definitions defined in GB 15213-2016 and IEC 60601-2-68.2014 apply to this document.

3.1 Image guided radiotherapy

IGRT A radiation therapy process. An image of the target area and its surrounding anatomy at the time of treatment to determine the therapeutic beam in the patient relative to

The position of the target zone is predetermined to make the necessary corrections to the predetermined position of the beam relative to the target zone.

[GB 15213-2016, definition 3.8]

3.2 Image reconstruction

A method of processing the acquired data into an image data set that can be used for analysis.

[IEC 60601-2-68.2014, definition.2011.3.210]

3.3 Image registration

A method of mapping or mapping a point in a set of image data sets with a corresponding point in another set of image data sets.

[IEC 60601-2-68.2014, definition.2011.3.211]

3.4 KV X-IGRT device kilovoltageX-IGRTequipment

X-IGRT equipment using kV X radiation.

[IEC 60601-2-68.2014, definition.201.3.213]

3.5 Megavolt X-IGRT device megavoltageX-IGRTequipment

X-IGRT equipment using megavolt X radiation. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY 1650-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY 1650-2019

$210.00