Scope

YY 1036-2004 is the English-translated version of 压陷式眼压计.

YY 1036-2004 is the Chinese pharmaceutical industry standard for impression (indentation) tonometers, the mechanical instruments that estimate intraocular pressure from how deep a weighted plunger indents the cornea, each scale division corresponding to 0.05 mm of indentation.

It covers classification, normal working conditions, the basic dimensions of the foot plate and plunger with their tolerances, the requirements and test methods, inspection rules with sampling under GB/T 2828 and GB/T 2829, marking, instructions for use, packaging, transport and storage.

The revision took ISO/TR 8612:1997 as its main reference but keeps national differences, such as a mass tolerance of ±0.20 g at scale position 5 and a tilt limit of 28°.

It replaces YY 91036-1999. Issued on 23 March 2004, it has applied since 1 January 2005.

Found what you need?

Document preview — YY 1036-2004

National Standard of the People's Republic of China

ICS
11.040.55
Classification
C 40
Replacing
YY 91036-1999

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Product Categories

Foreword

This standard is revised on the basis of YY 91036-1999 "indentation tonometer", this revision refers to ISO /T R8612.1997 "Ophthalmic instrument mechanical indentation tonometer", as the main basis for the revision, and according to the current situation in China, the relevant technical differences have been made appropriate The amendments are mainly as follows.

ISO /T R8612.1997 specifies the assembly quality requirements for hammer bows, hands, needles and fixed weights. When the pointer position is "5", The mass error of 5.5g is ±0.15g; this standard is ±0.20g.

The ISO /T R8612.1997 specifies that the inclination does not exceed 25°; this standard does not exceed 28°. Appendix A of this standard is a normative appendix.

1 Scope

This standard specifies the classification, requirements, test methods, inspection rules, signs, instructions for use, packaging, transportation and Storage.

This standard applies to indentation tonometer (hereinafter referred to as tonometer), which is used for measuring intraocular pressure.

2 Normative references

The terms in the following documents become the terms of this standard by reference to this standard. All dated references, followed by all Modifications (not including errata content) or revisions do not apply to this standard, however, parties to agreements based on this standard are encouraged to study Is it possible to use the latest version of these files? For undated references, the latest edition applies to this standard.

GB/T 1220-1992 stainless steel rod

GB/T 2828-1997 Batch-by-batch inspection sampling procedure and sampling table (for continuous batch inspection)

GB/T 2829-2002 Periodic inspection count sampling procedures and tables (applicable to the inspection of process stability)

GB 9969.1-1998 General instructions for the use of industrial products

3 Terms and definitions

The following terms and definitions apply to this standard.

3.1 Impression tonometer

It is an instrument for indirectly determining the intraocular pressure by measuring the indentation depth of the cornea according to a certain quality needle, on the tonometer scale, each cell is equivalent to the indentation depth of the cornea of 0.05 mm, and the intraocular pressure value is obtained according to the indentation depth and the weight of the weight.

3.2 Impression tonometry

The needle deforms the cornea to a quasi-equilibrium between internal and external pressure, and then the depression depth is measured.

4 Product Categories

4.1 The type of tonometer is a mechanical depression type.

4.3 The basic dimensions of the tonometer should be in accordance with Table 1.

Part name basic size tolerance The radius of curvature of the bottom of the foot tube is 15 ± 0.25 The diameter of the bottom surface of the foot tube is 10.1 ± 0.20 The bottom surface of the pressure pin has a radius of curvature of 15 ± 0.75

4.2 Normal working conditions

a) ambient temperature 10 ° C ~ 40 ° C;

b) relative temperature 30% to 75%;

c) The atmospheric pressure ranges from 700 hPa to 1060 hPa.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Editions of YY 1036

EditionTitleRevisionStatus
YY 1036-2004Impression tonometerscurrent editionCurrent
YY 91036-1999Impression tonometersprevious editionSuperseded

This page sells the current edition, YY 1036-2004. Earlier editions are listed for reference only.

How to Download YY 1036-2004

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY 1036-2004

$105.00