YY 0896-2013Medical electrical equipment - Part 2: Particular requirements for the safety of electromyographs and evoked response equipment (English PDF)
医用电气设备 第2部分:肌电及诱发反应设备安全专用要求
This is a limited preview
Buy now to download the full PDF (25 pages)
Need quotation for your management?
Get a formal quotation for YY 0896-2013 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Mandatory
Issue date
October 21, 2013
Implementation date
October 1, 2014
Scope
YY 0896-2013 is the English-translated version of 医用电气设备 第2部分:肌电及诱发反应设备安全专用要求.
YY 0896-2013 is the Chinese pharmaceutical industry standard for the safety of electromyographs and evoked response equipment, the instruments that record the electrical activity of muscle and nerve and the responses evoked by a stimulus.
It applies together with the general standard for medical electrical equipment, whose clauses it modifies one by one, and covers the classification, the identification, marking and documents, the power input, the protection against electric shock through the patient connections, the stimulator and the energy it may deliver, and the accuracy of the operating data. Issued on 21 October 2013, it has applied since 1 October 2014.
Found what you need?
Document preview — YY 0896-2013
National Standard of the People's Republic of China
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword4
- 1 Scope and object6
- 2 Terminology and definitions8
- 5 Classification9
- 6 Identification, marking and documents9
- 7 Power input11
- 14 Requirements related to classification12
- 20 Dielectric strength12
- 36 Electromagnetic compatibility13
- 42 Excessive temperatures14
- 46* Human errors14
- 50 Accuracy of operating data15
- 51 Protection against hazardous output16
- Annex L (normative) Normative references18
- Annex AA (informative) General guidance and rationale19
Foreword
Medical electrical equipment standards are a series of standards, consisting of two major parts.
- Part 1: General requirements for safety of medical electrical equipment;
- Part 2: Particular requirements for safety of medical electrical equipment. This Particular Standard is Part 2-40 of Medical electrical equipment.
This Particular Standard is the amendment and addition of GB 9706.1-2007 "Medical electrical equipment - Part 1: General requirements for safety".
This Particular Standard is drafted according to the rules given in GB/T 1.1-2009.
This Particular Standard uses redrafting method to amend and adopt the International Electrotechnical Commission Standard IEC 60601-2-40:1998 "Medical electrical equipment - Part 2-40.Particular requirements for the safety of electromyographs and evoked response equipment" (English version).
Main technical differences between this Standard and IEC 60601-2-40:1998 are as follows.
- Clause 36 in IEC 60601-2-40:1998 is the addition to the collateral standard IEC 60601-1-2:1993, and China's current electromagnetic compatibility standards YY 0505-2012 "Medical electrical equipment - Part 1: General requirements for safety - 2.Collateral standard. Electromagnetic compatibility - Requirements and tests" is equivalent to IEC 60601-1-2:2004.Therefore, in the development of this Particular Standard, the Standardization Administration of China believes that it is necessary to update the specifications on electromagnetic compatibility with reference to the requirements of the latest collateral standards.
- For the other International standards referenced in the standard, if the standard has been transformed into China's national standard, the referenced China's national standards shall prevail;
- DELETE the cover and foreword of IEC 60601-2-40:1998.
This Particular Standard is the amendment and addition of GB 9706.1-2007 "Medical electrical equipment - Part 1: General requirements for safety", so this Particular Standard takes priority over the General Standard.
1 Scope and object
This clause of the General Standard applies except as follows. […]
1.1 Scope
Addition.
This Particular Standard applies to ELECTROMYOGRAPHS as defined in 2.1.101 and EVOKED RESPONSE EQUIPMENT as defined in 2.1.102, hereinafter referred to as EQUIPMENT.
1.2 Object
Replacement.
The object of this Particular Standard is to establish particular requirements for the safety of ELECTROMYOGRAPHS and EVOKED RESPONSE EQUIPMENT as defined in 2.1.101 and 2.1.102, respectively.
1.3 Particular Standards
Addition. This Particular Standard refers to GB 9706.1-2007.
Part 1 is referred to in this Particular Standard either as the "General Standard" or as the "General Requirement(s)".
36 Electromagnetic compatibility
36.202.2.2 The use of the phantom is intended to standardize the testing for EMC, particularly for susceptibility.
Contamination of the display resulting from the radiated radiofrequency electromagnetic field tests is not considered to be hazardous and, therefore, not a non-compliance.
Instructions for use should specify maximum electromagnetic fields within which all performance specifications will be met, if these are necessarily lower than the levels specified for the tests of 36.202.2.1.
46 Switching on the ELECTRICAL STIMULATOR inadvertently is considered to be a normal occurrence since the ELECTRICAL STIMULATOR is likely to be short-circuited or open-circuited accidentally during use due to movements of the electrodes and/or the PATIENT.
50 Accuracy of operating data
50.1 A small increase in output amplitude may produce a disproportionate stimulus to the PATIENT. A control which enables the USER to adjust the output amplitude smoothly or in small increments is considered to be an important safety feature.
Limitation of the output available at the minimum setting of the output control enables the USER to commence stimulation from a low output level.
50.2 An accuracy of ± 30 % is considered to provide adequate safety, since the values selected are mainly determined by the electrophysiological responses and the subjective reaction of the PATIENT.
51 Protection against hazardous output
51.101 Supply voltage fluctuations not exceeding the limit of the General Standard should not influence the output parameters excessively.
51.102 The indication should advise the USER that the ELECTRICAL STIMULATOR is delivering stimuli, or that the ELECTRICAL STIMULATOR is armed to deliver stimuli as a result of further action by the USER, for example manual triggering.
51.105 The value of 125 dB HTL is taken from GB/T 7341.3-1998.
51.103 Experience shows
that the limits specified allow all known diagnostic applications to be carried out without exceeding the allowable value. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
Similar standards
How to Download YY 0896-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY 0896-2013
$135.00