Valid

YS/T 997.1-2014Methods for chemical analysis of antimony-doped tin oxide. Part 1: Determination od tin content. Potassium iodate titrimetric method (English PDF)

掺锑二氧化锡化学分析方法 第1部分:锡量的测定碘酸钾滴定法

Preview PDF

This is a limited preview

Buy now to download the full PDF (5 pages)

Need quotation for your management?

Get a formal quotation for YS/T 997.1-2014 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

October 14, 2014

Implementation date

April 1, 2015

Scope

YS/T 997.1-2014 is the English-translated version of 掺锑二氧化锡化学分析方法 第1部分:锡量的测定碘酸钾滴定法.

YS/T 997.1-2014 — YS/T of the provisions of the section 997 determination of antimony doped tin oxide in the amount of tin. This section applies to the determination of antimony tin oxide doped with tin in the amount of measurement range (mass fraction) 55.00% - 78.50%.

Found what you need?

Document preview — YS/T 997.1-2014

National Standard of the People's Republic of China

ICS
77.120.60
Classification
H 13

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Method summary
  • 3 Reagents

Foreword

YS/T 997 "Methods for chemical analysis of antimony-doped tin dioxide," is divided into three parts.

--- Part 1. Determination of tin content potassium iodate titration;

--- Part 2. Determination of antimony content cerium sulfate titration;

--- Part 3. Determination of chlorine content of thiocyanate mercury spectrophotometry.

This section YS/T Part 1 997.

This section drafted in accordance with GB/T 1.1-2009 given rules.

The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.

This section is drafted. Guangxi metallurgical products Quality Supervision, Inspection Station, Liuzhou one hundred tough special Advanced Materials Co., Ltd., Guangxi Analysis and Testing Center Zhuang Autonomous Region, Guilin University of Technology, Nanning Abacus detection technology limited liability company.

1 Scope

YS/T of the provisions of the section 997 determination of antimony doped tin oxide in the amount of tin.

This section applies to the determination of antimony tin oxide doped with tin in the amount of measurement range (mass fraction) 55.00% - 78.50%.

2 Method summary

After sodium oxide sample melted in hydrochloric acid solution was added reduced iron, antimony reduced to elemental separated and removed, with aluminum tin reduced to two Price, starch as the indicator for the end of bluish titration with potassium iodate standard solution titration test solution.

3 Reagents

Unless otherwise indicated, this part of the reagents were analytical reagent, the water of GB/T 6682 in the secondary water.

3.1 sodium peroxide.

3.2 reduced iron.

3.3 metal tin (Sn mass fraction >=99.99%).

3.4 aluminum (Al mass fraction >=99.5%), thickness of less than 0.1mm.

3.5 Sodium hydroxide solution (25g/L).

3.6 hydrochloride (11).

3.7 potassium iodate standard titration solution.

--- Preparation. Weigh 3.6g of potassium iodate dissolved in 500mL of water, add 18g potassium iodide and 2g of anhydrous sodium carbonate was dissolved, diluted with water to 2000mL, shake.

--- Calibration. Weigh 0.1200g metal tin (3.3) placed in 300mL conical flask, 2g ~ 3g reduced iron (3.2), 100mL of hydrochloric acid (3.6), the flask was connected to the reduction apparatus (FIG. 1). Low-temperature heating tin dissolved, add 20mL water, add 2.0g ~ 2.5g folded into small pieces of aluminum foil (3.4), continuous shaking the flask to dissolve most of the aluminum, and heating was continued to boil test solution to produce large bubbles 1min. Under the protection of carbon dioxide gas, the flasks were placed in cold water to cool to room temperature. Remove the cone Vial, immediately join 5mL starch solution (3.8), titration with potassium iodate standard solution (3.7) titration test solution was light blue as the end point.

While doing the blank test.

The actual concentration of potassium iodate standard solution titration according to formula (1).

59.355 × (V1-V0) × 10-3 (1) where.

C --- the actual concentration of potassium iodate standard titration solution, expressed in moles per liter (mol/L);

m0 --- metal tin in grams (g);

When V1 --- calibration standard solution titration tin volume of potassium iodate standard titration solution consumption in milliliters (mL);

V0 --- the calibration, the volume of potassium iodate titration reagent blank standard titration solution consumption in milliliters (mL);

59.355 --- tin (1/2Sn) molar mass in grams per mole (g/mol).

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.

How to Download YS/T 997.1-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
5 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 997.1-2014