YS/T 990.13-2014Methods for chemical analysis of copper mattee. Part 13:Determination of magnesium oxide content. Atomic absorption spectrmetry (English PDF)
冰铜化学分析方法 第13部分:氧化镁量的测定原子吸收光谱法
This is a limited preview
Buy now to download the full PDF (5 pages)
Need quotation for your management?
Get a formal quotation for YS/T 990.13-2014 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
October 14, 2014
Implementation date
April 1, 2015
Scope
YS/T 990.13-2014 is the English-translated version of 冰铜化学分析方法 第13部分:氧化镁量的测定原子吸收光谱法.
YS/T 990.13-2014 — This section YS/T 990 specifies the method for determination of copper matte MgO content. This section applies to the determination of copper ice MgO content. Determination of the range of 0.10 to 6.00%.
Found what you need?
Document preview — YS/T 990.13-2014
National Standard of the People's Republic of China
- ICS
- 77.120.30
- Classification
- H 13
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Method summary
- 3 Reagents
- 4 Instrument
Foreword
YS/T 990 "Methods for chemical analysis of copper matte" is divided into 18 parts.
--- Part 1 Determination of copper content iodometry;
--- Part 2. Determination of gold and silver atomic absorption spectroscopy and fire assay;
--- Part 3. Determination of sulfur content - Gravimetric method and combustion titration method;
--- Part 4. Determination of the amount of bismuth atomic absorption spectrometry;
--- Part 5. Determination of the amount of fluorine ion selective electrode method;
--- Part 6. Determination of lead content - Atomic absorption spectrometry and Na2EDTA titration;
--- Part 7. Determination of cadmium content - Atomic absorption spectrometry;
--- Part 8. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry, diethyl dithiocarbamate spectrophotometry silver and potassium bromate titration;
--- Part 9. Determination of iron content dichromate method;
--- Part 10. Determination of silicon dioxide content molybdenum blue spectrophotometry and silicon potassium fluoride titration;
--- Part 11. Determination of the amount of nickel atom absorption spectrometry;
--- Part 12. Determination of the amount of chromium oxide of aluminum Azure S Spectrophotometry;
--- Part 13. Determination of magnesium oxide content - Atomic absorption spectrometry;
--- Part 14. Determination of the amount of zinc atomic absorption spectrometry and Na2EDTA titration;
--- Part 15. Determination of antimony content - Atomic absorption spectrometry;
--- Part 16. Determination of mercury content - Cold atomic absorption spectrometry;
--- Part 17. Determination of the amount of cobalt atomic absorption spectrometry;
--- Part 18. lead, zinc, nickel, arsenic, bismuth, antimony, calcium, magnesium, cadmium, cobalt content - Inductively coupled plasma atomic emission spectrometry.
This section YS/T Part 13 990.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section is responsible for drafting unit. Zhongtiaoshan Nonferrous Metals Group Co., Ltd. Daye Nonferrous Metals Group Holdings Limited.
This section is drafted. Daye Nonferrous Metals Group Holdings Limited.
Participated in the drafting of this section. Beijing Nonferrous Metal Research Institute, Tongling Nonferrous Metals Group Holdings Co., Ltd., Yunnan Copper shares have Ltd., Yu Teng Hunan Nonferrous Metals Co., Ltd., Tianjin, People's Republic of China Exit Inspection and Quarantine.
1 Scope
This section YS/T 990 specifies the method for determination of copper matte MgO content.
This section applies to the determination of copper ice MgO content. Determination of the range of 0.10 to 6.00%.
2 Method summary
Samples with hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid dissolved in dilute hydrochloric acid medium, adding a certain amount of strontium chloride interference suppression elements, use Air - acetylene flame atomic absorption spectrometer wavelength 285.2nm at (adjust the angle of the burner), measuring the absorbance of magnesium oxide.
3 Reagents
Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.
3.1 hydrochloric acid (rho = 1.19g/mL).
3.2 hydrochloride (11).
3.3 nitric acid (rho = 1.42g/mL).
3.4 Hydrofluoric acid (rho = 1.13g/mL).
3.5 perchloric acid (rho = 1.67g/mL).
Standard stock solution 3.6 MgO. Magnesium oxide (wMgO>=99.99%) pre-ignition 1h at 600 °C, placed in a desiccator to cool to room temperature.
Weigh 0.5000g of magnesium oxide in 250mL beaker, add a small amount of wetting water, added 20mL of hydrochloric acid (3.2) is completely dissolved and transferred to 500mL Volumetric flask, dilute with water to volume, and mix. This solution 1mL 1mg containing magnesium oxide.
3.7 magnesium standard solution. Pipette 20.00mL magnesium accurate standard stock solution (3.6) in 100mL volumetric flask, was added 10mL Hydrochloric acid (3.2), dilute to the mark and mix. This solution 1mL containing 200µg magnesia.
3.8 strontium chloride solution. Weigh 30.43g strontium chloride (SrCl2 · 6H2O) in 250mL beaker, add 30mL water, 25mL hydrochloric acid (3.2) was dissolved and transferred to 500mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 20mg strontium.
3.9 Na2EDTA solution [c (Na2EDTA) ~0.10mol/L]. Weigh 18.62g Disodium ethylenediaminetetraacetate (C10H14N2O8Na2 · 2H2O), placed in 250mL beaker, after adding hot water dissolved and transferred to 500mL volumetric flask, dilute with water to volume, and mix.
4 Instrument
Atomic absorption spectrometer, with a magnesium hollow cathode lamp.
Under optimum working conditions for those who can reach the following indicators can be used.
--- Characteristic concentration. measurement solution with the matrix solution consistent characteristic concentration (appropriately adjusted burners corner), magnesium oxide should not be Greater than 0.411µg/mL.
--- Precision. standard solution with the highest concentration of 11 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0%;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
How to Download YS/T 990.13-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 990.1-2014 — Methods for chemical analysis of copper matte. Part 1: Determination of copper content. Iodine titration method
YS/T 990.10-2014 — Methods for chemical analysis of copper matte. Part 10: Determination of silicon dioxide content. Molybdenum blue spectrophotometry and potassium fluosilicate titrimetric method
YS/T 990.11-2014 — Methods for chemical analysis of copper matte, Part 11: Determination of nickel content, Atomic absorption spectrmetry