YS/T 953.10-2014Methods for chemical analysis of fire smelting nickel substrate material - Part 10: Determination of nickel, chromium, manganese, cobalt, copper and phosphorus contents - Inductively coupled plasma atomic emission spectrometric method (English PDF)
火法冶炼镍基体料化学分析方法 第10部分:镍、铬、锰、钴、铜、磷量的测定电感耦合等离子体原子发射光谱法
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for YS/T 953.10-2014 in 30 minutes.
Issued by
Ministry of Industry and Information Technology of the PRC
Level / Type
National · Recommended
Issue date
October 14, 2014
Implementation date
April 1, 2015
Scope
YS/T 953.10-2014 is the English-translated version of 火法冶炼镍基体料化学分析方法 第10部分:镍、铬、锰、钴、铜、磷量的测定电感耦合等离子体原子发射光谱法.
YS/T 953.10-2014 is the Chinese standard "Methods for chemical analysis of fire smelting nickel substrate material - Part 10: Determination of nickel, chromium, manganese, cobalt, copper and phosphorus contents - Inductively coupled plasma atomic emission spectrometric method".
Its scope clause reads: This Part of YS/T 953 specifies the inductively coupled plasma atomic emission spectrometric method for the determination of nickel, chromium, manganese, cobalt, copper and phosphorus contents in the fire smelting nickel substrate material.
This Part applies to the determination of nickel, chromium, manganese, cobalt, copper and phosphorus contents in the fire smelting nickel substrate material. The determination range is shown in Table 1.
Table 1 -- Determination range. Its clauses include method summary; reagents; apparatus; samples; analytical procedures; calculation of analysis results; precision; test report.
It was issued by the Ministry of Industry and Information Technology of the PRC on 2014-10-14 and took effect on 2015-04-01.
Found what you need?
Document preview — YS/T 953.10-2014
National Standard of the People's Republic of China
- ICS
- 77.120.40
- Classification
- H 13
Issued by: Ministry of Industry and Information Technology of the PRC
Contents
- Foreword...3
- 1 Scope...5
- 2 Normative references...5
- 3 Method summary...6
- 4 Reagents...6
- 5 Apparatus...7
- 6 Samples...7
- 7 Analytical procedures...7
- 8 Calculation of analysis results...9
- 9 Precision...9
- 10 Test report...10
1 Scope
This Part of YS/T 953 specifies the inductively coupled plasma atomic emission spectrometric method for the determination of nickel, chromium, manganese, cobalt, copper and phosphorus contents in the fire smelting nickel substrate material.
This Part applies to the determination of nickel, chromium, manganese, cobalt, copper and phosphorus contents in the fire smelting nickel substrate material.
The determination range is shown in Table 1.
Table 1 -- Determination range
2 Normative references
The following documents are indispensable for the application of this document.
For the dated references, only the editions with the dates indicated are applicable to this document. For the undated references, the latest edition (including all the amendments) are applicable to this document.
GB/T 20066 Steel and iron - Sampling and preparation of samples for the determination of chemical composition
3 Method summary
USE hydrochloric acid, nitric acid and hydrofluoric acid to dissolve the test portion; ADD perchloric acid to blow off the fluoride. If necessary, add yttrium as an internal standard;
4 Reagents
Unless otherwise specified, only reagents confirmed to be analytically pure and distilled water or deionized water or water of equivalent purity are used in the analysis.
4.1 Hydrochloric acid (rho=1.19 g/mL).
4.2 Nitric acid (rho=1.42 g/mL).
4.6 Mixed standard solution. Respectively PIPETTE 5.00 mL each of copper
and phosphorus single-element standard stock solutions (4.5), 10.00 mL each of chromium, cobalt, and manganese single-element standard stock solutions (4.5),
4.7 Yttrium internal standard solution. PIPETTE 25.00 mL of yttrium single-
element standard stock solution (4.5) into a 1000 mL volumetric flask; ADD 50 mL of hydrochloric acid (4.1); USE water to dilute to the mark and mix well. 1 mL of this solution contains 25 µg of yttrium.
5 Apparatus
5.1 Inductively coupled plasma atomic emission spectrometer
Spectral line. There is no special requirement for analysis line. Only recommended analysis lines are listed in Table 2.
5.2 Short-term stability requirements for the apparatus. When the maximum
mass concentration solution of the measured element is continuously measured for 5 times, the relative standard deviation of the absolute intensity of the emitted light shall be less than 0.8%.
6 Samples
TAKE and prepare samples according to GB/T 20066 or appropriate national or industrial standards.
7 Analytical procedures
7.1 Mass of test portion
According to Table 3, weigh the test portion, accurate to 0.0001 g.
7.4 Determination
7.4.1 Dissolution of test portion
PLACE the test portion (7.1) in a polytetrafluoroethylene beaker; ADD 5 mL of hydrochloric acid (4.1), 5 mL of nitric acid (4.2); HEAT to no longer react. ADD
2~3 drops of hydrofluoric acid (4.3);
7.4.2 Measurement
On the inductively coupled plasma emission spectrometer, after the apparatus runs stably, under the selected apparatus working conditions, use the prepared standard series solution (7.5) to standardize or calibrate the working curve. The correlation coefficient of the working curve of each element shall be above
0.999.Otherwise it is necessary to re-standardize or re-prepare standard series solution for standardization. MEASURE the spectral intensity of the analysis test solution (7.4.1) and the blank test solution (7.3). According to the working curve, the apparatus automatically processes the data, calculates and outputs the mass concentration of each element.
8 Calculation of analysis results
The content of each element is calculated by mass fraction wx, expressed in %, calculated according to formula (1).
9 Precision
9.1 Repeatability
For the measured values of two independent test results obtained under repeatability conditions, within the average range given below, the absolute difference between the two test results does not exceed the repeatability limit (r).
9.2 Reproducibility
For the measured values of two independent test results obtained under reproducibility conditions, within the average range given below, the absolute difference between the two test results does not exceed the reproducibility limit (R).
10 Test report
This clause specifies the content to be included in the test report. At least the following shall be given.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
Referenced standards
How to Download YS/T 953.10-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 20066-2006 — Steel and iron -- Sampling and preparation of samples for the determination of chemical composition
YS/T 953.1-2014 — Methods for chemical analysis of fire smelting nickel substrate material - Part 1: Determination of nickel content - Dimethylglyoxime spectrophotometric method and dimethylglyoxime gravimetric method
YS/T 953.11-2014 — Methods for chemical analysis of fire smelting neckel substrate material. Part 11: Determination of Lead, Arsenic, Cadmium and Mercury contents. Inductively coupled plasma-mass spectrometric method
Secure payment via Stripe
Payments accepted
YS/T 953.10-2014