YS/T 95.2-2016Aluminum foil for air conditioner - Part 2: Precoated aluminum foil (English PDF)
Also coversYST95.2-2016
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for YS/T 95.2-2016 in 30 minutes.
Issued by
Ministry of Industry and Information Technology of the People's Republic of China
Level / Type
National · Recommended
Issue date
April 5, 2016
Implementation date
September 1, 2016
Scope
YS/T 95.2-2016 (Aluminum foil for air conditioner - Part 2: Precoated aluminum foil) is available as an English-translated PDF.
YS/T 95.2-2016 — This Part of YS/T 95 specifies the requirements, test methods, inspection rules and marks, packaging, transport, storage, quality certificate and order form (or contract) content of precoated aluminum foil for air conditioner heat sink.
This Part is applicable to aluminum foil for air conditioner heat sink of which the surface is covered with a corrosion-resistant layer and a hydrophilic coating (hereinafter referred to as precoated foil).
Found what you need?
Document preview — YS/T 95.2-2016
National Standard of the People's Republic of China
- ICS
- 77.150.10
- Classification
- H 61
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- Foreword...3
- 1 Scope...5
- 2 Normative references...5
- 3 Requirements...6
- 4 Test methods...11
- 5 Inspection rules...14
- 6 Marks, packaging, transport, storage...18
- 7 Order form (or contract)...20
Foreword
YS/T 95 "Aluminum foil for air conditioner radiator" consists of two parts.
- Part 1.Finstock;
- Part 2.Precoated aluminum foil.
This Part is Part 2 of YS/T 95.
This Part was drafted in accordance with the rules given in GB/T 1.1-2009.
This Part replaces YS/T 95.2-2009 "Aluminum foil for air conditioner - Part 2.
Precoated aluminum foil". Compared with YS/T 95.2-2009, the main technical
changes in this Part are as follows.
- deleted product models of P14, P23, P24, P43, P44, P51, P52, P61, P62;
- added product models of P31, P32;
- tightened harmful element limit value;
- added requirements for coating resistances to bending and acid;
- added provisions for measuring the hydrophilic angle after immersion in oil
resistance test method;
- modified requirements for coating appearance quality;
- the supplier and the purchaser are required to agree on the type of the no-
clean volatile oil for the hydrophilic angle of the test process;
- specified that harmful elements or harmful substances are tested according
to GB/T 26125, and antibacterial properties are tested according to GB/T
21866;
- modified test method for alkali resistance;
- modified test method for coating odor;
- added requirements for contact surface diameter of solvent resistant
hammer.
This Part was proposed by and shall be under the jurisdiction of National
Technical Committee on Non-ferrous Metal of Standardization Administration of
China (SAC/TC 243).
The drafting organizations of this Part. Yitong Technology Group Co., Ltd.,
Guangzhou Huigu Chemical Co., Ltd., Zhenjiang Dingsheng Aluminum Industry
Co., Ltd., Ruyuan Yao Autonomous County Yangzhiguang Hydrophilic Foil Co.,
Ltd., Jiangsu Chang Aluminum Co., Ltd., Xiamen Xiashun Aluminum Foil Co.,
Ltd.
Main drafters of this Part. Zhou Linjie, Zhou Yingchun, Dong Qibao, Li Yuefeng,
Shi Yuzhen, Zhang Jianming, Lao Xiaofeng, Wang Xiguang.
Versions of standard substituted by this Standard are.
- YS/T 95.2-2001, YS/T 95.2-2009.
Aluminum foil for air conditioner -
Part 2.Precoated aluminum foil
1 Scope
This Part of YS/T 95 specifies the requirements, test methods, inspection rules
and marks, packaging, transport, storage, quality certificate and order form (or
contract) content of precoated aluminum foil for air conditioner heat sink.
This Part is applicable to aluminum foil for air conditioner heat sink of which the
surface is covered with a corrosion-resistant layer and a hydrophilic coating
(hereinafter referred to as precoated foil).
2 Normative references
The following referenced documents are indispensable for the application of
this document. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any
amendments) applies.
GB/T 1740, Methods of test for resistance to heat and humidity of paint films
GB/T 1771, Paints and varnishes - Determination of resistance to neutral salt
spray (fog)
GB/T 3199, Wrought aluminum and aluminum alloy products - Packing,
marking, transporting and storing
GB/T 6461, Methods for corrosion testing of metallic and other inorganic
coatings on metallic substrates - Rating of test specimens and manufactured
articles subjected to corrosion tests
GB/T 6682, Water for analytical laboratory use - Specification and test
methods
3 Requirements
3.1 Product classification
3.1.1 Coating structure
See Figure 1 for coating structure.
3.1.4 Marking
The marking of the precoated foil is expressed in the order of product name,
standard number, product model, function code, designation, state, and size
specifications. Marking examples are as follows.
3.2 Chemical composition
The chemical composition of the precoated foil (except Cd, Pb, Hg, Cr6+) shall
comply with the requirements of YS/T 95.1.The limits of harmful elements or
harmful substances in the precoated foil shall comply with the requirements of
Table 2.
3.4 Adhesion
The precoated foil shall be easy to expand over the entire length of the roll, no
sticking or tearing when unfolded.
3.5 Mechanical properties, process performance
The tensile mechanical properties and process properties of the precoated foil
shall meet the requirements of YS/T 95.1.
3.7 Appearance quality
3.7.1 The surface color of the precoated foil is determined by both parties. There
shall be no obvious chromatic aberration, leakage coating, corrosion, holes, etc.,
which affect the performance of the coating and the defects of the user. Defects
such as subtle color points, imprints, etc. that do not affect the use are allowed.
4 Test methods
4.1 Chemical composition
4.2 Size deviation
The size deviation of precoated foil is inspected according to YS/T 95.1.
4.3 Adhesion
Adhesion is inspected by unrolling the precoated foil roll.
4.6 Hydrophilicity
Hydrophilicity is tested according to the method specified in GB/T 22638.9.The
type of no-clean volatile oil used in the process of hydrophilic angle detection is
negotiated between the supplier and the purchaser and specified in the order
form (or contract). When the purchaser has special requirements on drying
temperature and drying time, it shall be indicated in the order form (or contract).
4.7 Anti-cupping
Carry out the test according to the provisions of GB/T 9753.Indentation depth
is 5mm.
4.9 Bending resistance
Make the end of the sample (in the length direction, the area 13mm~20mm from
the end) bend 180°, that is, bend to the two planes of the sample (0T as shown
in Figure 2). Make the two flat fitting parts of the sample bend 180° (1T as shown
in Figure 2). After the folded portion of the sample is bent by 180° (2T as shown
in Figure 2), the bending shall be continued for 180° (3T as shown in Figure 2).
Adhesive tape with adhesion greater than 10N/25mm is covered on the curved
surface of the top of the folded portion of the sample (end point along the length
of the sample). Press to remove the air under the adhesive tape. Quickly pull
up the tape. Observe the coating for delamination.
4.11 Heat and humidity resistance
The test method for heat and humidity resistance is carried out in accordance
with the provisions of GB/T 1740.The determination level is in accordance with
the provisions of GB/T 6461.The defect area and corresponding protection
level generated by the test are shown in Table 4.
4.17 Solvent resistance
Wrap a 1kg hammer with at least six layers of gauze. The diameter of the
contact surface between the hammer and the sample is 14mm ± 0.5mm. After
the iron wrapped with the gauze is filled with methyl ethyl ketone, the surface
of the sample is rubbed along the same straight path along the same straight
path, at a rate of one round trip per second. Wipe one back and forth as one
time, 30 times in total. Observe whether the bottom is exposed. The gauze shall
be kept moist during the test.
4.19 Coating antibacterial property
Antibacterial property of precoated foil is inspected according to GB/T 21866.
4.20 Inspection method of appearance quality
Appearance quality is visually inspected.
5 Inspection rules
5.1 Check and acceptance
5.1.1 The precoated foil shall be inspected by the supplier to ensure that the
product quality complies with the provisions of this Part (or order contract). And
fill in the quality certificate.
5.3 Weighing
The product shall be weighed according to actual weight.
5.4 Inspection items
Each batch of precoated foil shall be subject to the inspections of chemical
composition (except Cd, Pb, Hg, Cr6+), tensile strength, elongation after break,
cupping value, size deviation, adhesion, joint, appearance quality, initial
hydrophilic angle, anti-cupping, adhesion, bending resistance.
5.6.4 If the inspection result of harmful elements or harmful substances in any
sample or the inspection result of coating performance is unqualified, this batch
of products shall be determined as unqualified.
5.6.5 If the appearance quality of any product is unqualified, the product
represented by the sample shall be determined as unqualified.
6 Marks, packaging, transport, storage
6.1 Marks
6.1.1 Product mark
Mark (or label) the precoated foil on each roll that has passed the inspection.
The following information shall be marked.
6.1.2 Packaging box mark
The packaging box mark for precoated foil shall comply with GB/T 3199.
6.2 Packaging, transport, storage
Precoated foil roll packaging is divided into packaging box and simple
packaging. The packaging method shall be agreed by the supplier and the
purchaser and shall be indicated in the order form (or contract). Transport and
storage are in accordance with GB/T 3199.
6.3 Quality certificate
Each batch of precoated foil shall have quality certificate that meet the
requirements of this Part, indicating the following information.
7 Order-form (or contract) contents
The order-form (or contract) for the product listed in this Part shall contain the
following information.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1740Determination of resistance to heat and humidity of paint films
- GB/T 1771Paints and Varnishes -- Determination of resistance to neutral salt spray (fog)
- GB/T 3199Packing, marking, transport and storage of wrought aluminium and aluminium alloy products
- GB/T 6461Methods for corrosion testing of metallic and other inorganic coatings on metallic substrates -- Rating of test specimens and manufactured articles subjected to corrosion tests
- GB/T 6682Water for analytical laboratory use - Specification and test methods
How to Download YS/T 95.2-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1740-2007 — Determination of resistance to heat and humidity of paint films
GB/T 1771-2007 — Paints and Varnishes -- Determination of resistance to neutral salt spray (fog)
GB/T 17710-2008 — Information technology -- Security technique -- Check character systems
Secure payment via Stripe
Payments accepted
YS/T 95.2-2016
$120.00