Valid

YS/T 746.9-2010Methods for chemical analysis of lead-free tin-based solders. Part 9: Determination of zinc content. Flame atomic absorption spectrometric method and Na2EDTA titrimetric method (English PDF)

无铅锡基焊料化学分析方法 第9部分:锌含量的测定 火焰原子吸收光谱法和Na2EDTA滴定法

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for YS/T 746.9-2010 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

November 22, 2010

Implementation date

March 1, 2011

Scope

YS/T 746.9-2010 is the English-translated version of 无铅锡基焊料化学分析方法 第9部分:锌含量的测定 火焰原子吸收光谱法和Na2EDTA滴定法.

YS/T 746.9-2010 — 1 Scope YS/T 746 This section provides lead-free tin-based solders Determination of zinc content. This section applies to the determination of tin-based solders without zinc content. Measurement range. 0.0010% to 0.100%.

Found what you need?

Document preview — YS/T 746.9-2010

National Standard of the People's Republic of China

ICS
77.040.30
Classification
H 13

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Method, flame atomic absorption spectrometry
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument

Foreword

YS/T 746 "non-Pb-based solder chemical analysis method" is divided into 17 parts.

--- Part 1 Determination of tin content Coke sexual gallic acid Covering - lead nitrate titration method

--- Part 2 of silver content - Flame atomic absorption spectrometry and potentiometric titration with potassium thiocyanate

--- Part 3 of copper content - Flame atomic absorption spectrometry and titration with sodium thiosulfate

--- Part 4 of lead content - Flame Atomic Absorption Spectrometry

--- Part 5 of bismuth content - Flame atomic absorption spectrometry and titration Na2EDTA

--- Part 6 of antimony content - Flame Atomic Absorption Spectrometry

--- Part 7 Determination of iron content by flame atomic absorption spectrometry

--- Part 8 of arsenic content of arsenic, antimony molybdenum blue spectrophotometric method

--- Part 9 Determination of zinc content by flame atomic absorption spectrometry and titration Na2EDTA Part 10 Determination of aluminum content --- first electrothermal atomic absorption spectrometry

--- Part 11 of cadmium content - Flame Atomic Absorption Spectrometry

--- Part 12 Determination of indium titration Na2EDTA

--- Part 13 Determination of nickel content by flame atomic absorption spectrometry

--- Part 14 Determination of the phosphorus content of the first crystal violet - heteropoly acid phosphovanadomolybdate spectrophotometry

--- Part 15 Determination of germanium content salicylfluorone spectrophotometry

--- Part 16 Determination of rare earth Arsenazo III spectrophotometry

--- Part 17 silver, copper, lead, bismuth, antimony, iron, arsenic, zinc, aluminum, cadmium, nickel, indium content was measured by inductively coupled plasma optical emission Spectroscopy Part is divided into 9 parts.

This section is in accordance with GB/T 1.1-2009 given rules drafted.

The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.

This section is drafted. Yunnan Tin Group Co., Ltd.

Participated in the drafting of this section. Guangxi China Tin Group Co., Ltd. Yunnan Hualian Zinc indium.

1 Method, flame atomic absorption spectrometry

1 Scope

YS/T 746 This section provides lead-free tin-based solders Determination of zinc content.

This section applies to the determination of tin-based solders without zinc content. Measurement range. 0.0010% to 0.100%.

2 Method summary

Sample hydrochloric acid - hydrogen peroxide dissolved in hydrochloric acid - hydrobromide exclude volatile tin, antimony in nitric acid medium, flame atomic absorption spectrometry at a wavelength of 213.9nm, with flame atomization, air - acetylene flame measured absorbance of zinc.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.

3.1 hydrochloric acid (rho1.19g/mL), pure class distinctions.

3.2 nitrate (rho1.42g/mL), pure class distinctions.

3.3 Hydrogen peroxide (30%).

3.4 hydrobromide (rho1.49g/mL).

3.5 nitric acid (11).

HCl 3.6 - hydrobromic acid (11).

3.7 standard zinc stock solution. Accurately weigh 0.1000g zinc metal (>=99.99%), zinc placed in 200mL beaker, add 20mL nitrate Acid (3.5), cover sheet pan, heat gently to dissolve, cooled to room temperature and transferred to 1000mL volumetric flask, dilute to the mark with water, mix and transferred to plastic bottles in storage. This solution 1mL containing 100µg zinc.

3.8 Zinc standard solution. Pipette 10.00mL standard zinc stock solution (3.7) in 100mL volumetric flask, add 2mL nitric acid (3.2) with Diluted with water to the mark, mix and transferred to a plastic bottle storage solution 1mL containing 10µg zinc.

4 Instrument

Atomic absorption spectrometer, with zinc hollow cathode lamp.

Under optimum working conditions for those who can reach the following indicators can be used.

--- Characteristic concentration. a solution in the matrix is consistent with the measured solution, characterized in zinc concentration should not exceed 0.01µg/mL.

--- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0%;

With the lowest concentration of standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

How to Download YS/T 746.9-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 746.9-2010

$135.00