Valid

YS/T 74.10-2010Methods of chemical anaysis of cadmium. Part 10: Determination of silver content. Flame atomic absorption spectrometry (English PDF)

镉化学分析方法 第10部分:银量的测定火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for YS/T 74.10-2010 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

November 22, 2010

Implementation date

March 1, 2011

Scope

YS/T 74.10-2010 is the English-translated version of 镉化学分析方法 第10部分:银量的测定火焰原子吸收光谱法.

YS/T 74.10-2010 — YS/T of the provisions of section 74 of the method for the determination of cadmium in silver content. This section applies to the determination of cadmium in silver content. Measurement range. 0.00020% to 0.0050%.

Found what you need?

Document preview — YS/T 74.10-2010

National Standard of the People's Republic of China

ICS
77.120.70
Classification
H 13
Replacing
YS/T 74.10-1994

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Principle of the method
  • 3 Reagents
  • 4 Instrument

Foreword

YS/T 74-2010 "cadmium chemical analysis method" is divided into 11 parts.

--- Part 1. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry;

--- Part 2. Determination of antimony content hydride generation - atomic fluorescence spectrometry;

--- Part 3. Determination of nickel content by electrothermal atomic absorption spectrometry;

--- Part 4. Determination of lead content by flame atomic absorption spectrometry;

--- Part 5. Determination of the amount of copper diethyl dithiocarbamate spectrophotometry lead;

--- Part 6. Determination of zinc content - Flame atomic absorption spectrometry;

--- Part 7. Determination of iron content of 1,10 phenanthroline spectrophotometry;

--- Part 8. Determination of thallium content of crystal violet spectrophotometry;

--- Part 9. Determination of tin content by hydride generation - atomic fluorescence spectrometry;

--- Part 10. Determination of the amount of silver by flame atomic absorption spectrometry;

--- Part 11. Inductively coupled plasma atomic arsenic, antimony, nickel, lead, copper, zinc, iron, thallium, tin and silver content of the emitted light Spectroscopy.

This section 10.

This section drafted in accordance with GB/T 1.1-2009 given rules.

The partial replacement of YS/T 74.10-1994 "cadmium chemical analysis by flame atomic absorption spectrometry silver amount", this part of the original standard Quasi compared to the main changes are as follows.

--- Text format has been modified;

--- Complements the precision, quality assurance and control provisions;

--- Increase the warning prompt;

--- Increasing the test report clause.

The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.

This section is responsible for drafting unit. MCC Huludao Nonferrous Metals Group Co., Ltd.

This section is drafted. Shenzhen Lingnan Nonferrous Metals Co., Ltd. Shaoguan smelter.

Participated in the drafting of this section. Zhuzhou Smelter Group Co., Ltd., MCC Huludao Nonferrous Metals Group Co., Ltd., Beijing Mining and Metallurgy Research Institute, Henan Yuguang Gold & Lead Co., Ltd.

1 Scope

YS/T of the provisions of section 74 of the method for the determination of cadmium in silver content.

This section applies to the determination of cadmium in silver content. Measurement range. 0.00020% to 0.0050%.

2 Principle of the method

Sample decomposition with nitric acid, in dilute nitric acid medium, using air - acetylene flame atomic absorption spectrometer measured at a wavelength of 328.1nm Absorbance, using a calibration curve obtained by the amount of silver.

3 Reagents

Production of solutions and experiments with water are double-distilled water.

Nitrate 3.1 (rho1.42g/mL).

3.2 nitric acid (11).

3.3 Cadmium matrix solution. Weigh 20g metal cadmium (wCd>=99.99% and wAg0.0001%), placed in 500mL beaker, fractional total Was added 80mL of nitric acid (3.2), until the vigorous reaction was heated to dissolve completely, purge nitrogen oxides micro-boiling, cooled, transferred to 100mL capacity Dilution bottle with water to volume, and mix. This solution 1mL containing 200mg cadmium.

3.4 Silver standard stock solution. Weigh 0.1000g of metallic silver (wAg>=99.99%), placed in a beaker of 200mL, 10mL of nitric acid was added (3.2), cover sheet pan, heated slowly to dissolve completely removed, washed with water and dish table cup wall, cooled and transferred to 1000mL volumetric flask.

100mL nitric acid (3.2), dilute to the mark and mix. This solution 1mL containing 100µg silver.

3.5 silver standard solution. Pipette 10.00mL silver standard stock solution (3.4) in 1000mL volumetric flask 2mL nitric acid (3.2), Dilute with water to volume, and mix. This solution 1mL containing 10µg silver.

4 Instrument

Atomic absorption spectrometer, with a silver hollow-cathode lamp.

Under optimum working conditions, who can reach the following indicators are, it can be used.

--- Sensitivity. measurement solution matrix consistent solution, features silver concentration should be less than 0.022µg/mL.

--- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0% the lowest concentration of standard solution used (instead of "zero" standard solution) absorbance measured 10 times, and the standard deviation should not exceed the maximum concentration

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

How to Download YS/T 74.10-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 74.10-2010

$105.00