YS/T 715.3-2009Methods for chemical analysis of selenium dioxide. Part 3: Determination of chlorine content. Silver chlorine turbidimetrion method (English PDF)
二氧化硒化学分析方法 第3部分:氯量的测定 氯化银浊度法
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for YS/T 715.3-2009 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
December 4, 2009
Implementation date
June 1, 2010
Scope
YS/T 715.3-2009 is the English-translated version of 二氧化硒化学分析方法 第3部分:氯量的测定 氯化银浊度法.
YS/T 715.3-2009 — YS/T of the provisions of section 715 of the method for the determination of selenium dioxide in the chlorine content. This section applies to the determination of selenium dioxide in the chlorine content. Measurement range. 0.0010% to 0.050%.
Found what you need?
Document preview — YS/T 715.3-2009
National Standard of the People's Republic of China
- ICS
- 77.120.10
- Classification
- H 12
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Method summary
- 3 Reagents
- 4 Instrument
- 5 Sample
- 6 Step, Analysis
- 6.1 Sample
Foreword
YS/T 715 "selenium dioxide chemical analysis method" is divided into five parts.
--- Part 1. Determination of the amount of selenium dioxide, sodium thiosulfate titration;
--- Part 2. arsenic, cadmium, iron, mercury, lead content - Inductively coupled plasma atomic emission spectrometry;
--- Part 3. Determination of chlorine content of silver chloride turbidimetric method;
--- Part 4. residue on ignition - Gravimetric method;
--- Part 5. water-insoluble content - Gravimetric method.
This section YS/T Part 3 715.
The non-ferrous metal part by the National Standardization Technical Committee and centralized.
This section is responsible for drafting unit. Tongling Nonferrous Metals Group Holdings Limited.
This section is drafted. Guangzhou Nonferrous Metal Research Institute.
Participated in the drafting of this section. Tongling Nonferrous Metals Group Holdings Co., Jiangxi Copper Corporation.
1 Scope
YS/T of the provisions of section 715 of the method for the determination of selenium dioxide in the chlorine content.
This section applies to the determination of selenium dioxide in the chlorine content. Measurement range. 0.0010% to 0.050%.
2 Method summary
Sample was dissolved in water, glycerol in the presence of silver nitrate and chlorine generated silver chloride emulsion, measured at 420nm wavelength spectrophotometer the amount of the absorbance.
3 Reagents
Unless otherwise indicated in the analysis using only the reagents and recognized as distilled or deionized water or equivalent purity analytical grade, this section Test water is deionized water, third grade water specifications.
Nitrate 3.1 (rho1.42g/mL).
Glycerin 3.2 (1 + 1).
3.3 silver nitrate solution (10g/L).
3.4 Storage chlorine standard solution. Weigh 1.6485g reference sodium chloride (pre-ignition to constant weight at 400 °C ~ 500 °C, cooled in a dryer to room temperature) was dissolved in water and transferred to 1000mL volumetric flask, dilute with water to the mark. This solution 1mL 1mg containing chlorine.
3.5 Chlorine Standard Solution A. Pipette 10.00mL chlorine standard stock solution (3.4) into 100mL volumetric flask, dilute to the mark with water, shake uniform. This solution 1mL containing 100µg chlorine.
3.6 chlorine standard solution B. Pipette 10.00mL chlorine standard solution A (3.5) into 100mL volumetric flask, dilute to the mark with water, shake uniform. This solution 1mL containing 10µg chlorine.
4 Instrument
Spectrophotometer.
5 Sample
Sample required uniform, dry and seal intact.
6 Step, Analysis
6.1 Sample
In dry conditions, according to Table 1 quickly and accurately weighed sample (5), accurate to 0.0001g.
Table 1 sample amount
Chlorine mass fraction /% sample mass/g dispensing volume of test solution/mL 0.0010 0.0030 2.0 full amount > 0.0030 to 0.0075 2.0 10 > 0.0075 0.030 1.0 5 > 0.030 to 0.050 0.5 5
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
How to Download YS/T 715.3-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 715.1-2009 — Methods for chemical analysis of selenium dioxide. Part 1: Determination of selenium dioxide content. Sodium thiosulfate titration
YS/T 715.2-2009 — Methods for chemical analysis of selenium dioxide. Part 2: Determination of arsenic, cadmium, iron, mercury, lead contents. Inductively coupled plasma-atomic emission spectrometry
YS/T 715.4-2009 — Methods for chemical analysis of selenium dioxide. Part 4: Determination of burning residue. Gravimetric analysis
Secure payment via Stripe
Payments accepted
YS/T 715.3-2009
$105.00