YS/T 587.10-2016Calcined coke for carbon anode--Part 10: Determination of bulk density (English PDF)
炭阳极用煅后石油焦检测方法 第10部分:振实密度的测定
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for YS/T 587.10-2016 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
April 5, 2016
Implementation date
September 1, 2016
Scope
YS/T 587.10-2016 is the English-translated version of 炭阳极用煅后石油焦检测方法 第10部分:振实密度的测定.
YS/T 587.10-2016 — This part of YS/T 587 specifies the method for determining the true density of petroleum coke after calcination. This part is suitable for the determination of the real density of petroleum coke after calcination.
The method 1 is suitable for the determination of particle size in the range of 0.25mm ~ (TBD); Method 2 is suitable for the use of vibration particle size range of 0.212mm ~ 7.00mm (VBD) of the 2 kg calcined petroleum coke sample, and the maximum particle size of the particles in the sample was measured within the above particle size range Degree and minimum particle size ratio should be less than 2 2, should be less than 2.
Found what you need?
Document preview — YS/T 587.10-2016
National Standard of the People's Republic of China
- ICS
- 71.100.10
- Classification
- Q 52
- Replacing
- YS/T 587.10-2006
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Method 1. Tap method
- 2.1 Principle of the method
- 2.2 Instruments and devices
Foreword
YS/T 587 "Carbon anode with calcined petroleum coke after the test method" a total of 14 parts.
- Part 1. Determination of ash;
- Part 2. Determination of moisture;
- Part 3. determination of volatiles;
- Part 4. Determination of sulfur;
- Part 5. Determination of trace elements;
- Part 6. Determination of powder resistivity;
- Part 7. Determination of CO2 reactivity - Mass loss method;
- Part 8. Determination of air reactivity - Mass loss method;
- Part 9. Determination of true density;
- Part 10. Determination of tap density;
- Part 11. Determination of particle stability;
- Part 12. Determination of particle size distribution;
- Part 13. Determination of Lc values;
Part 14. Determination of the Hadgrove index.
This section is part 10 of YS/T 587.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This section is a revision of YS/T 587.10-2006, compared with YS/T 587.10-2006, the main technical changes are as follows.
- the vibration method (method 2) is added on the basis of the tapping method (method 1);
--- In the case of editorial changes to the tap method, refer to ISO 10236.:1995 to modify the repeatability limit from <=0.02g/cm3 is <= 0.01g/cm3, and the reproducibility limit is changed from <=0.05g/cm3 to <=0.02g/cm3.
This part of the National Nonferrous Metals Standardization Technical Committee (SAC/TC243) proposed and centralized.
This part of the main drafting unit. China Aluminum Zhengzhou Nonferrous Metal Research Institute Co., Ltd., nonferrous metals Technology and Economic Research Institute.
This part participates in the drafting unit. Jinan Aohai Carbon Co., Ltd., Ningxia Ningping Carbon Co., Ltd., Zhengzhou Haoyu Carbon Material Limited company, Shandong Chenyang new carbon materials Co., Ltd., cable-Development Co., Ltd., Shandong Yanzhou Carbon Products Co., Ltd., Feicheng Prosperity Special Graphite Co., Ltd.
This part of the main drafters. Zhang Shuzhao, Guo Yongheng, Huang Hua, Li Bo, Zhao Chunfang, Lu Hongsen, Yu Lei, Liu Zhen, Cao Peifeng, Xi Zhaoyang, Yu Yiru, Gao Shuei, Chen Xiaojun, Zhao Qingbo.
This part of the previous version of the standard to replace the release of the situation.
YS/T 587.10-2006.
Determination of Petroleum Coke in Carbon Anode by Calcined Part 10. Determination of tap density
1 Scope
This part of YS/T 587 specifies the method for determining the true density of petroleum coke after calcination.
This part is suitable for the determination of the real density of petroleum coke after calcination. The method 1 is suitable for the determination of particle size in the range of 0.25mm ~ (TBD); Method 2 is suitable for the use of vibration particle size range of 0.212mm ~ 7.00mm (VBD) of the 2 kg calcined petroleum coke sample, and the maximum particle size of the particles in the sample was measured within the above particle size range Degree and minimum particle size ratio should be less than 2 2, should be less than 2.
2 Method 1. Tap method
2.1 Principle of the method
The tap density depends on the size, shape and porosity of the particles. Samples of similar particle size and shape can be obtained by comparing the tap density and true density to estimate the porosity. Porosity is an important parameter that affects the quality and performance of the prebaked anode.
The volume of the material is determined to be determined after a certain amount of material is determined, and the tap density is calculated from the known mass divided by the measured volume.
2.2 Instruments and devices
2.2.1 Tap method The measuring device of the tap density is shown in Figure 1, which includes.
--- Measuring tube. the quality of 190g ± 5g, scale 0mL ~ 250mL, the accuracy of 1mL.
--- cylinder holder. the quality of 450g ± 5g guide piston.
--- Pincer device. every minute to enhance and drop the guide piston 250 ± 15 times, the height of 3mm ± 0.1mm, with the number of beat Recorder.
2.2.2 Test sieve. Screen diameter 8.0mm, 4.0mm, 2.0mm, 1.0mm, 0.5mm, 0.25mm.
2.2.3 Oven. temperature can be controlled at 110 °C ± 5 °C.
2.2.4 Feeder. Feed to the measuring tube in a controlled manner.
2.2.5 balance. range of not less than 1000g, accuracy is better than 0.1g.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
How to Download YS/T 587.10-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 587.1-2006 — Calcined coke for prebaked blocks. Testing methods. Part 1: Determination of ash content
YS/T 587.11-2006 — Calcined coke for prebaked blocks. Testing methods. Part 11: Determination of grain stability
YS/T 587.12-2006 — Calcined coke for prebaked blocks. Testing methods. Part 12: Determination of particle size distribution
Secure payment via Stripe
Payments accepted
YS/T 587.10-2016
$184.00