YS/T 581.17-2010Determination of chemical contents and physical properties of aluminium fluoride. Part 17: Determination of flow time (English PDF)
氟化铝化学分析方法和物理性能测定方法 第17部分:流动性的测定
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for YS/T 581.17-2010 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
November 22, 2010
Implementation date
March 1, 2011
Scope
YS/T 581.17-2010 is the English-translated version of 氟化铝化学分析方法和物理性能测定方法 第17部分:流动性的测定.
YS/T 581.17-2010 — YS/T 581 This part specifies the method for measuring the liquidity of aluminum fluoride. This section applies to the determination of the inherent liquidity aluminum fluoride through a special funnel.
Found what you need?
Document preview — YS/T 581.17-2010
National Standard of the People's Republic of China
- ICS
- 71.100.10
- Classification
- H 21
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Principle of the method
- 3 Instruments and devices
- 4 Sample Preparation
Foreword
YS/T 581 "aluminum fluoride chemical analysis methods and determination of physical performance" is divided into 17 parts.
--- Part 1. Determination of the content of water in wet weight method;
--- Part 2. Determination of burning reductions;
--- Part 3. distillation - thorium nitrate volumetric method for the determination of fluorine content;
--- Part 4. Determination of aluminum content - EDTA volumetric method;
--- Part 5. Determination by flame atomic absorption spectrometry sodium content;
--- Part 6. molybdenum blue spectrophotometric determination of silicon dioxide content;
--- Part 7. phenanthroline spectrophotometric determination of ferric oxide content;
--- Part 8. Determination of sulfate content barium sulphate gravimetric method;
--- Part 9. molybdenum blue spectrophotometric determination of phosphorus pentoxide content;
Part --- Article 10. X-ray fluorescence spectrometric method for the determination of sulfur content;
--- Part 11. sample preparation and storage;
--- Part 12. Determination of particle size distribution by sieving;
--- Part 13. Determination of angle of repose;
--- Part 14. Determination of bulk density;
--- Part 15. Determination of free alumina content;
--- Part 16. Determination of Elements in X-ray fluorescence spectrometry;
--- Part 17. Determination of flow.
This is Part 17.
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This part of the draft law duplicate reference AS2879.9-2002 "Determination of aluminum oxide Part IX of the flow of time," the preparation, and Degree of consistency AS2879.9-2002 of non-equivalent.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section drafted by the Aluminum Corporation of China Zhengzhou Research Institute.
This section is Hunan Nonferrous Xiangxiang Fluorine Chemical Co., Ltd., Henan Weilai Aluminum (Group) Co., Neimengguhuo coal Hongjun Aluminum Co.
Ltd. participated in the drafting.
1 Scope
YS/T 581 This part specifies the method for measuring the liquidity of aluminum fluoride.
This section applies to the determination of the inherent liquidity aluminum fluoride through a special funnel.
2 Principle of the method
A certain quality of aluminum fluoride through a special funnel, flow time measurement sample all you want. Liquidity to flow when required Room to represent.
3 Instruments and devices
3.1 Instrument. usually manual or automatic measuring device measurement, automatic measurement apparatus shown in Figure 1.
3.2 Funnel. Exact making a stainless steel funnel (Fig. 2), the apparatus outlet diameter of 3.95mm ~ 4.00mm wear resistant stainless steel. The diameter shall be calibrated. The funnel needed to use dry and clean, otherwise the flow of time can not be repeated.
3.3 Timer. Stop watch or other automated means to accurately 0.1s.
3.4 Balance. a sense of the amount of 0.1g.
3.5 Test sieve. sieve 500µm, for removing large particle size.
1 Automatic flow time measurement device
4 Sample Preparation
4.1 The sample is placed in a tray, tile thickness of not more than 5mm, the balance in the test chamber atmosphere 2h.
4.2 The sample was equilibrated by the test sieve (3.5) to remove large particles, the lower part of the screen the sample into three parts, each part about 105g ~ 120g, each for measuring times.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
How to Download YS/T 581.17-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 581.1-2024 — Chemical analysis methods and physical property determination methods of aluminum fluoride - Part 1: Determination of moisture content and loss on ignition - Acid-base titration
YS/T 581.10-2025 — Methods for chemical analysis and physical properties test of aluminium fluoride - Part 10: Determination of elements content - X-ray fluorescence spectrometric method
YS/T 581.11-2006 — Determination of chemical contents and physical properties of aluminium fluoride. Part 11: Preparation and storage of test samples
Secure payment via Stripe
Payments accepted
YS/T 581.17-2010
$115.00