YS/T 581.16-2008Chemical analysis methods and determination of physical performance of industrial aluminium fluoride. Part 16: X-ray fluorescence spectrometric method for the determination of elements content (English PDF)
氟化铝化学分析方法和物理性能测定方法 第16部分:X射线荧光光谱分析法测定元素含量
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for YS/T 581.16-2008 in 30 minutes.
Issued by
National Development and Reform Commission
Level / Type
National · Recommended
Issue date
March 12, 2008
Implementation date
September 1, 2008
Scope
YS/T 581.16-2008 is the English-translated version of 氟化铝化学分析方法和物理性能测定方法 第16部分:X射线荧光光谱分析法测定元素含量.
YS/T 581.16-2008 — This section provides aluminum fluoride, fluorine, aluminum, sodium, silicon, iron, sulfur, phosphorus content (F, Al, Na, SiO2, Fe2O3, SO2-4, P2O5 represented) Measurement method.
This section applies to fluorine, aluminum, sodium, silicon, iron, sulfur, aluminum fluoride determination of phosphorus content. Determination of the range in Table 1.
Table 1 Component measuring range /% F 50.00 ~ 68.00 Al 25.00 ~ 36.00 Na 0.020 ~ 10.00 SiO2 0.010 ~ 0.60 Component measuring range /% Fe2O3 0.010 ~ 0.50 SO2-4 0.10 ~ 2.00 P2O5 0.0020 ~ 0.30
Found what you need?
Document preview — YS/T 581.16-2008
National Standard of the People's Republic of China
- ICS
- 77.120.10
- Classification
- H 30
Issued by: National Development and Reform Commission
Contents
- Foreword
- 1 Scope
- 2 Principle of the method
- 3 Reagents
- 4 Instrument
- 5 Sample
Foreword
YS/T 581 "aluminum fluoride chemical analysis methods and determination of physical performance" is divided into 16 parts.
--- Part 1. Determination of the content of water in wet weight method;
--- Part 2. Determination of burning reductions;
--- Part 3. distillation - thorium nitrate volumetric method for the determination of fluorine content;
--- Part 4. Determination of aluminum content - EDTA volumetric method;
--- Part 5. Determination by flame atomic absorption spectrometry sodium content;
--- Part 6. molybdenum blue spectrophotometric determination of silicon dioxide content;
--- Part 7. phenanthroline spectrophotometric determination of ferric oxide content;
--- Part 8. Determination of sulfate content barium sulphate gravimetric method;
--- Part 9. molybdenum blue spectrophotometric determination of phosphorus pentoxide content;
Part --- Article 10. X-ray fluorescence spectrometric method for the determination of sulfur content;
--- Part 11. sample preparation and storage;
--- Part 12. Determination of particle size distribution - sieving method;
--- Part 13. Determination of angle of repose;
--- Part 14. Determination of bulk density;
--- Part 15. Determination of free alumina content;
--- Part 16. Determination of Elements in X-ray fluorescence spectroscopy.
This is Part 16.
Appendix A of this section is an informative annex.
The non-ferrous metal part by the National Standardization Technical Committee and centralized.
This part of the Aluminum Corporation of China Zhengzhou Research Institute, China Nonferrous Metals Industry Institute of Standards Metrology and Quality is responsible for drafting.
This section is more fluoride Chemical Co., Neimengguhuo coal Hongjunlvdian limited liability company, Fujian Nanping Aluminium Co., Ltd. participated Drafted.
1 Scope
This section provides aluminum fluoride, fluorine, aluminum, sodium, silicon, iron, sulfur, phosphorus content (F, Al, Na, SiO2, Fe2O3, SO2-4, P2O5 represented) Measurement method.
This section applies to fluorine, aluminum, sodium, silicon, iron, sulfur, aluminum fluoride determination of phosphorus content. Determination of the range in Table 1.
Table 1
Component measuring range /% F 50.00 ~ 68.00 Al 25.00 ~ 36.00 Na 0.020 ~ 10.00 SiO2 0.010 ~ 0.60 Component measuring range /% Fe2O3 0.010 ~ 0.50 SO2-4 0.10 ~ 2.00 P2O5 0.0020 ~ 0.30
2 Principle of the method
Sample anhydrous lithium tetraborate and lithium metaborate mixed flux melted, add a small amount of lithium bromide (or iodide) as a release agent. In the melt prototype Melted into glass samples. Measured by X-ray fluorescence spectrometer. Theoretical coefficient alpha or fundamental parameter calibration between the absorbent element -Enhancement.
3 Reagents
3.1 anhydrous lithium tetraborate and lithium metaborate mixed flux [Li2B4O7 (67%) + LiBO2 (33%)]. at 700 °C burning 2h, dry place Dryer saved.
3.2 remover. a saturated solution of lithium bromide or ammonium iodide solution (300g/L).
3.3 Sample Monitoring. Monitor sample should be stable glass, contains all the elements of calibration, so that its content should be less than the statistical error count rate or equal to the count rate calibration element statistical error.
4 Instrument
Platinum 4.1 - gold alloy crucible (95% Pt + 5% Au).
4.2 platinum - gold alloy casting (95% Pt + 5% Au). bottom mold material thickness of about 1mm, making it difficult to deformation.
Note. The sample vessel melt casting mold can be combined. If the sample in the crucible directly after melt molding, the bottom surface of the inner wall of the crucible is required smooth.
4.3 fusion machine. automatic flame melt melting prototype or high-frequency inductors, if other types of prototype melting temperature not lower than 1100 °C, and can be controlled Temperature, control accuracy of ± 15 °C.
4.4 wavelength dispersive X-ray fluorescence spectrometer. end window rhodium anode X-ray tube.
5 Sample
The specimen shall conform YS/T 581.11 in 3.3 requirements.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
How to Download YS/T 581.16-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 581.1-2024 — Chemical analysis methods and physical property determination methods of aluminum fluoride - Part 1: Determination of moisture content and loss on ignition - Acid-base titration
YS/T 581.10-2025 — Methods for chemical analysis and physical properties test of aluminium fluoride - Part 10: Determination of elements content - X-ray fluorescence spectrometric method
YS/T 581.11-2006 — Determination of chemical contents and physical properties of aluminium fluoride. Part 11: Preparation and storage of test samples
Secure payment via Stripe
Payments accepted
YS/T 581.16-2008
$135.00