YS/T 581.15-2021Determination of chemical content and physical properties of aluminium fluoride - Part 15: Free alumina content (English PDF)
Also coversYST581.15-2021
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for YS/T 581.15-2021 in 30 minutes.
Issued by
Ministry of Industry and Information Technology of PRC
Level / Type
National · Recommended
Issue date
March 5, 2021
Implementation date
July 1, 2021
Scope
YS/T 581.15-2021 (Determination of chemical content and physical properties of aluminium fluoride - Part 15: Free alumina content) is available as an English-translated PDF.
YS/T 581.15-2021 is the Chinese standard "Determination of chemical content and physical properties of aluminium fluoride - Part 15: Free alumina content". Its scope clause reads: This document specifies a method for the determination of free alumina in aluminum fluoride.
Gravimetric method is used as arbitration inspection method. This document is applicable to the determination of free alumina content in aluminum fluoride. The gravimetric method is applicable to aluminum fluoride products, which are produced by wet processes.
The chemical composition balance calculation method is applicable to aluminum fluoride products, which are produced by all processes. The measurement range is 0.1% ~ 15%.
Its clauses include terms and definitions; weight method. It was issued by the Ministry of Industry and Information Technology of PRC on 2021-03-05 and took effect on 2021-07-01.
Found what you need?
Document preview — YS/T 581.15-2021
National Standard of the People's Republic of China
- ICS
- 71.100.10
Issued by: Ministry of Industry and Information Technology of PRC
Contents
- Foreword...3
- Introduction...5
- 1 Scope...6
- 2 Normative references...6
- 3 Terms and definitions...7
- 4 Weight method...7
- 5 Chemical composition balance calculation method...9
- 6 Test report...12
1 Scope
This document specifies a method for the determination of free alumina in aluminum fluoride. Gravimetric method is used as arbitration inspection method.
This document is applicable to the determination of free alumina content in aluminum fluoride. The gravimetric method is applicable to aluminum fluoride products, which are produced by wet processes. The chemical composition balance calculation method is applicable to aluminum fluoride products, which are produced by all processes. The measurement range is 0.1% ~ 15%.
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, for dated reference documents, only the version corresponding to the date applies to this document; for undated reference documents, the latest version (including all amendments) applies to this document.
GB/T 8170 Rules of rounding off for numerical values & expression and judgement of limiting values
YS/T 581.3 Determination of chemical content and physical properties of aluminum fluoride - Part 3: Determination of fluoride content
YS/T 581.4 Determination of chemical contents and physical properties of aluminum fluoride - Part 4: Determination of aluminum by the EDTA volumetric method
YS/T 581.5 Determination of chemical contents and physical properties of aluminum fluoride - Part 5: Determination of sodium by flame atomic absorption spectrometric method
YS/T 581.6 Determination of chemical contents and physical properties of aluminum fluoride - Part 6: Determination of silica content by the molybdenum blue photometric
3 Terms and definitions
There are no terms or definitions to be defined in this document.
4 Weight method
4.1 Principle
The fluoride salt in the specimen is dissolved in the hot boric acid-sodium hydroxide solution, whilst the free Al2O3 is not dissolved. After filtration, burn it and weigh the mass of the precipitate. Calculate the free alumina content.
4.2 Reagents
Unless otherwise stated, only reagents confirmed to be of analytical grade and distilled or deionized water or water of relative purity, are used in the analysis.
4.2.1 Boric acid-sodium hydroxide solution: Dissolve 12.5 g of boric acid and 30 g of sodium hydroxide in 500 mL of water. Mix well.
4.2.2 Phenolphthalein ethanol solution: 10 g/L.
4.3 Instruments and equipment
4.3.1 Platinum crucible: The top diameter is about 30 mm, the bottom diameter is about
20 mm, the height is about 35 mm. It is equipped with a lead lid.
4.3.2 High temperature furnace: It can control the temperature at 1000 °C ± 20 °C.
4.4 Specimen
Grind and mix the sample, to make it pass through a 74 µm standard sieve. Bake it in an oven at 110 °C ± 5 °C for 2 h. Cool it to room temperature, in a desiccator.
4.5 Test procedures
4.5.1 Sample
Weigh 1.0 g of specimen (4.4), accurate to 0.0001 g.
4.5.2 Parallel test
Conduct two tests in parallel. Take the average value.
4.5.3 Determination
4.5.3.1 Place the platinum crucible and lid (4.3.1) into the high temperature furnace
(4.3.2). Burn it, at 1000 °C ± 20 °C for 30 minutes. Take out the platinum crucible and lid. Put them into a desiccator. Cool it to room temperature. Weigh the platinum crucible and lid (m0), accurate to 0.0002 g.
4.5.3.2 Place the specimen into a 400 mL beaker. Add 150 mL of water. Use a glass rod to stir it, to evenly distribute the specimen at the bottom of the beaker. Cover with a watch glass. Heat and boil for 15 min ~ 20 min (continuously stir and maintain the original volume). Then add 50 mL of boric acid-sodium hydroxide solution (4.2.1).
Continue to heat and boil for 15 minutes (continuously stir and maintain the original volume). Remove it. Use slow filter paper to filter it. Transfer the precipitate to the filter paper. Use hot water to rinse it, until it is neutral (use phenolphthalein ethanol solution (4.2.2) for inspection).
4.5.3.3 Place the precipitate together with the filter paper into a constant weight
platinum crucible (4.5.3.1). Ash it on the electric furnace. Then move it to a high temperature furnace (4.3.2), which has a temperature of 1000 °C ± 20 °C. Burn for 30 minutes. Take out. Put in a desiccator. Cool to room temperature. Weigh it (m1), accurate to 0.0001 g.
4.6 Processing of test data
The content of free alumina is calculated as the mass fraction of free alumina wAl2O3, which is calculated according to formula (1):
Where:
m1 - The mass of the platinum crucible, lid, sediment, in grams (g);
m0 - The mass of the platinum crucible and lid, in grams (g);
m - The mass of sample, in grams (g).
Calculation results are expressed to two decimal places. Numerical rounding off is performed, in accordance with the provisions of GB/T 8170.
4.7 Precision
4.7.1 Repeatability
For the measured value of two independent test results, which are obtained under repeatability conditions, within the average range given below, the absolute difference between the two test results does not exceed the repeatability limit (r); those exceeding the repeatability limit (r) does not exceed 5%. The repeatability limit (r) is obtained, by linear interpolation or extrapolation method, according to the data in Table 1.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
Referenced standards
Normative references
YS/T 581.3 · YS/T 581.4 · YS/T 581.5 · YS/T 581.6
How to Download YS/T 581.15-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 8170-2008 — Rules of rounding off for numerical values & expression and judgement of limiting values
YS/T 581.2-2006 — Determination of chemical contents and physical properties of aluminium fluoride. Part 2: Determination of ignition loss
YS/T 575.4-2025 — Methods for Chemical Analysis of Bauxite – Part 4: Determination of Iron Oxide Contents
Secure payment via Stripe
Payments accepted
YS/T 581.15-2021
$160.00