Valid

YS/T 556.7-2009Methods for chemical analysis of antimony concentrates. Part 7: Determination of mercury content. Atomic fluorescence spectrometry (English PDF)

锑精矿化学分析方法 第7部分:汞量的测定原子荧光光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for YS/T 556.7-2009 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

December 4, 2009

Implementation date

June 1, 2010

Scope

YS/T 556.7-2009 is the English-translated version of 锑精矿化学分析方法 第7部分:汞量的测定原子荧光光谱法.

YS/T 556.7-2009 — This section YS/T 556 specifies the method for determination of the amount of mercury in antimony concentrate. This section applies to the determination of the amount of mercury antimony concentrate. Measurement range. 0.0001% to 0.010%.

Found what you need?

Document preview — YS/T 556.7-2009

National Standard of the People's Republic of China

ICS
73.060
Classification
D 42
Replacing
YS/T 556.7-2006

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Method summary
  • 3 Reagents and materials
  • 4 Instrument

Foreword

YS/T 556-2009 "Methods for chemical analysis of antimony concentrate," a total of 16 parts.

--- Part 1. Determination of antimony content cerium sulfate titration;

--- Part 2. Determination of arsenic content potassium bromate titration;

--- Part 3. Determination of lead content by flame atomic absorption spectrometry;

--- Part 4. Wet water storage Gravimetric method;

--- Part 5. Determination of zinc content - Flame atomic absorption spectrometry;

--- Part 6. Determination of the amount of selenium by hydride generation - atomic fluorescence spectrometry;

--- Part 7. Determination of the amount of mercury atomic fluorescence spectrometry;

--- Part 8. Determination of sulfur content - Combustion neutralization method;

--- Part 9. Determination of the amount of gold fire assay;

--- Part 10. Determination of copper content - Flame atomic absorption spectrometry;

--- Part 11. Determination of cadmium content by flame atomic absorption spectrometry;

--- Part 12. Determination of bismuth content by flame atomic absorption spectrometry;

--- Part 13. Determination of nickel content by flame atomic absorption spectrometry;

--- Part 14. Determination of the amount of silver by flame atomic absorption spectrometry;

--- Part 15. antimony, tin measured by hydride generation - atomic fluorescence spectrometry;

--- Part 16. Determination of antimony metal content by inductively coupled plasma emission spectrometry.

This section YS/T 556 Part 7.

"Antimony concentrates - Determination of mercury content" in this section instead of YS/T 556.7-2006 (formerly GB/T 15080.7-1994).

Compared with YS/T 556.7-2006, this part of the following changes.

--- Instead of the original cold vapor atomic absorption spectrometry using atomic fluorescence spectrometry.

The non-ferrous metal part by the National Standardization Technical Committee and centralized.

This section is responsible for drafting unit. tin mine Twinkling Star Antimony Industry Co., Ltd., Beijing General Research Institute of Mining and Metallurgy.

This section is drafted. Guangzhou Research Institute of Nonferrous Metals, Tin mine flash Star Antimony Industry Co., Ltd.

Participated in the drafting of this section. Hunan Chenzhou Mining Co., Ltd.

1 Scope

This section YS/T 556 specifies the method for determination of the amount of mercury in antimony concentrate.

This section applies to the determination of the amount of mercury antimony concentrate. Measurement range. 0.0001% to 0.010%.

2 Method summary

Sample was dissolved in aqua regia, nitric acid in the medium to potassium borohydride as a reducing agent, with argon as the carrier gas, and the resulting mercury vapor atomic import stone British furnace atomizer, the fluorescence intensity was measured on a mercury atomic fluorescence spectrometer.

3 Reagents and materials

Unless otherwise indicated, the reagents used in this section refer to analytical reagent and water and secondary water.

3.1 hydrochloric acid (rho1.19g/mL), pure class distinctions.

3.2 nitrate (rho1.42g/mL), pure class distinctions.

3.3 nitric acid (1 + 4).

3.4 aqua regia (1 + 1). three volumes of hydrochloric acid (3.1), one volume of nitric acid (3.2), and four volumes of water mixed preparation.

3.5 potassium borohydride solution. Weigh 0.25g potassium borohydride, dissolved in 500mL5g/L potassium hydroxide solution, and the time is now equipped with.

3.6 potassium dichromate solution (50g/L).

3.7 Storage mercury standard solution. Weigh 0.1354g previously dried 24h of mercury dichloride was dissolved in a small amount of water, nitric acid was added 50mL (3.2), 10mL potassium dichromate solution (3.6) and transferred to 1000mL volumetric flask, dilute with water to volume, and mix. This solution containing 1mL 100µg mercury.

Mercury 3.8 Standard Solution A. Pipette 10.00mL mercury standard stock solution (3.7) in 100mL volumetric flask, was added 5mL of nitric acid (3.2), 1mL potassium dichromate solution (3.6), diluted with water to volume, and mix. This solution 1mL containing 10µg mercury.

3.9 Mercury standard solution B. Pipette 2.00mL mercury standard solution A (3.8) in 200mL volumetric flask, was added 10mL of nitric acid (3.2), 2mL potassium dichromate solution (3.6), diluted with water to volume, and mix. This solution 1mL containing 0.1µg of mercury, the time is now equipped with.

3.10 argon (purity >=99.99%).

4 Instrument

Atomic fluorescence spectrometer, with a special mercury hollow cathode lamp.

Under optimum working conditions for those who can reach the following indicators can be used.

--- Detection limit. not more than 1 × 10-10g/mL.

--- Precision. The fluorescence intensity was measured with a standard solution of mercury 8ng/mL 10 times, and the standard deviation should not exceed the mean fluorescence intensity 5.0%.

--- Linear curve. The curve is divided into five sections according to concentration, the fluorescence intensity of the fluorescence intensity difference between the highest and the lowest segment of poor section Value ratio shall not be less than 0.8.

Atomic fluorescence spectrometer with reference to working conditions.

--- Lamp current. 20mA;

--- Negative high voltage. 260V;

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

How to Download YS/T 556.7-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 556.7-2009

$125.00