YS/T 53.3-2010Methods for chemical analysis of copper, lead, zinc original and tailing ores. Part 3: Determination of silver content. Flame atomic absorption spectrometric (English PDF)
铜、铅、锌原矿和尾矿化学分析方法 第3部分:银量的测定火焰原子吸收光谱法
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for YS/T 53.3-2010 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
November 22, 2010
Implementation date
March 1, 2011
Scope
YS/T 53.3-2010 is the English-translated version of 铜、铅、锌原矿和尾矿化学分析方法 第3部分:银量的测定火焰原子吸收光谱法.
YS/T 53.3-2010 — YS/T of the provisions of section 53 of the method for the determination of copper, lead, zinc ore and tailings in silver content. This section applies to the determination of copper, lead, zinc ore and tailings in silver content. This section measurement range. 0.50g/t ~ 200g/t.
Found what you need?
Document preview — YS/T 53.3-2010
National Standard of the People's Republic of China
- ICS
- 77.120.01
- Classification
- H 14
- Replacing
- YS/T 53.3-1992
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Method summary
- 3 Reagents
- 4 Instrument
Foreword
YS/T 53 "Copper, lead, zinc ore tailings and chemical analysis method" is divided into three parts.
--- Part 1. Determination of the amount of gold fire assay enrichment - flame atomic absorption spectrometry;
--- Part 2. determination of gold by Flow Injection Micro - column separation -8531 fiber enrichment - flame atomic absorption spectrometry;
--- Part 3. Determination of the amount of silver by flame atomic absorption spectrometry.
This section is part 3.
This section is in accordance with GB/T 1.1-2009 given rules drafted.
This part is YS/T 53.3-1992 amendments. This section compared with YS/T 53.3-1992, have the following main changes.
--- Increased the preamble;
--- Omitted "reference standard" one;
--- Text format has been modified;
--- Increasing the precision part;
--- Increased quality assurance and control provisions.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section is drafted. Beijing Mining Research Institute, Guangzhou Nonferrous Metal Research Institute.
Participated in the drafting of this section. Lingnan Shaoguan smelter Ltd., Chinalco Luoyang Copper Co., Ltd., Henan Yuguang Gold & Lead Group Co., Ltd., Tongling Nonferrous Metals Group Holdings Limited, Shuikoushan Nonferrous Metals Group Co., Ltd.
1 Scope
YS/T of the provisions of section 53 of the method for the determination of copper, lead, zinc ore and tailings in silver content.
This section applies to the determination of copper, lead, zinc ore and tailings in silver content. This section measurement range. 0.50g/t ~ 200g/t.
2 Method summary
Sample was dissolved with hydrochloric acid, nitric acid, hydrofluoric acid and perchloric acid. Air - acetylene flame atomic absorption spectrometer wavelength 328.1nm at measuring the absorbance of silver. Silver content is calculated using the working curve method.
3 Reagents
Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.
3.1 hydrochloric acid.
3.2 nitrate.
3.3 perchloric acid.
3.4 hydrofluoric acid.
3.5 butyl acetate.
3.6 diphenylthiourea - butyl acetate (2g/L). 1g 500mL diphenyl thiourea were dissolved butyl acetate (3.5) in.
3.7 Silver standard stock solution. Weigh 0.5000g of metallic silver (>=99.99%), placed in a beaker of 200mL, 25mL of nitric acid was added (3.2), cover the surface of the pan, boil until completely dissolved and get rid of nitrogen oxides, removed, washed with water and dish table Beibi, cooled to room temperature. Moved 500mL brown volumetric flask, dilute with water to volume, and mix. 1mL solution containing 1mg silver.
3.8 silver standard solution A. Pipette 10.00mL silver standard stock solution (3.7) into 1000mL brown volumetric flask, add salt 100mL Acid (3.1), dilute to the mark and mix. This solution 1mL containing 10µg silver.
3.9 silver standard solution B. Pipette 25.00mL silver standard solution A (3.8) previously placed there 25mL hydrochloric acid (3.1) of 250mL brown Color volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 1µg silver.
4 Instrument
Atomic absorption spectrometer (with a background subtraction function), with a silver hollow-cathode lamp.
Under optimum working conditions for those who can reach the following indicators can be used.
--- Sensitivity. the substrate solution consistent with the measurement solution, features silver concentration should be less than 0.030µg/mL;
--- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0%;
The lowest concentration of standard solution used (instead of "zero" standard solution) absorbance measured 10 times, and the standard deviation should not exceed the maximum concentration 0.5% of the mean absorbance of the standard solution;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
How to Download YS/T 53.3-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 53.1-2010 — Methods for chemical analysis of copper, lead, zinc original and tailing ores. Part 1: Determination of gold content. Fire assay-flame atomic absorption spectrometric
YS/T 53.2-2010 — Methods for chemical analysis of copper, lead, zinc original and tailing ores. Part 2: Determination of gold content. Separation and preconcentration by flow injection and 8531 fiber micro-column-the flame atomic absorption spectrum method
YS/T 1115.10-2026 — Chemical analysis methods of copper, lead and zinc ores and tailings - Part 10: Determination of gold, silver, molybdenum, arsenic, tungsten, bismuth, gallium, indium, thallium, selenium, tellurium and germanium contents - Inductively coupled plasma mass spectrometry
Secure payment via Stripe
Payments accepted
YS/T 53.3-2010