Valid

YS/T 521.2-2009Methods for chemical analysis of blister copper. Part 2: Determination of gold and silver contents. Fire assay method (English PDF)

粗铜化学分析方法 第2部分:金和银量的测定 火试金法

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for YS/T 521.2-2009 in 30 minutes.

Issued by

Ministry of Industry and Information Technology of the People’s Republic of China

Level / Type

National · Recommended

Issue date

December 4, 2009

Implementation date

June 1, 2010

Scope

YS/T 521.2-2009 is the English-translated version of 粗铜化学分析方法 第2部分:金和银量的测定 火试金法.

YS/T 521.2-2009 — This Part of YS/T 521 specifies the method for determining gold and silver contents in blister copper. This Part applies to the determination of gold and silver contents in blister copper.

Determination range. gold mass fraction >= 0.5g/t; silver mass fraction >= 20g/t.

Found what you need?

Document preview — YS/T 521.2-2009

National Standard of the People's Republic of China

ICS
77.120.30
Classification
H 13

Issued by: Ministry of Industry and Information Technology of the People’s Republic of China

Contents

  • Foreword...3
  • 1 Scope...5
  • 2 Method summary...5
  • 3 Reagents...5
  • 4 Instruments and equipment...6
  • 5 Analytical procedure...6
  • 6 Calculation of analysis results...9
  • 7 Precision...11
  • 8 Quality assurance and control...12

Foreword

YS/T 521-2009 Methods for chemical analysis of blister copper is divided into

6 parts.

— Part 1.Determination of copper content - Iodimetry

— Part 2.Determination of gold and silver contents - Fire assay method

— Part 3.Determination of arsenic content

Method 1 Hydride generation - atomic fluorescence spectrometric

method

Method 2 Potassium bromate titration

— Part 4.Determination of lead, bismuth and antimony contents - Flame

atomic absorption spectrometry

— Part 5.Determination of zinc and nickel contents - Flame atomic

absorption spectrometry

— Part 6.Determination of arsenic, antimony, bismuth, lead, zinc and

nickel contents - Inductively coupled plasma-atomic emission

spectrometry

This Part is Part 2 of YS/T 521.

This Part replaces YS/T 521.3-2006 Methods for chemical analysis of blister

copper - Determination of gold and silver contents (original GB/T

5120.3-1995). Compared with YS/T 521.3-2006, this Part has the following

changes.

— The text format was modified;

— Precision as well as quality assurance and control provisions were

supplemented.

This Part was proposed by and shall be under the jurisdiction of the National

Technical Committee for Standardization of Nonferrous Metals.

Responsible drafting organization of this Part. Daye Nonferrous Metals Group

Holdings Co., Ltd.

Participating drafting organizations of this Part. Beijing General Research

Institute of Mining & Metallurgy, Jiangxi Copper Co., Ltd., and Jinchuan

Group Ltd.

Methods for chemical analysis of blister copper –

Part 2.Determination of gold and silver contents -

Fire assay method

1 Scope

This Part of YS/T 521 specifies the method for determining gold and silver

contents in blister copper.

This Part applies to the determination of gold and silver contents in blister

copper. Determination range. gold mass fraction >= 0.5g/t; silver mass fraction

>= 20g/t.

2 Method summary

The sample is dissolved in sulfuric acid. The gold and silver precipitates

obtained after copper removal by filtration are ashed, compounded and

melted to obtain an appropriate amount of lead buckle. The gold and silver

contents are determined gravimetrically after the lead buckle is cupellated.

The correction method is carried out by adding pure copper as a matrix and

adding pure gold and pure silver along with the sample for determination. It is

corrected according to its recovery rate or corrected by the cupel and slag

melting method.

3 Reagents

Unless otherwise stated, only analytically pure reagents and distilled or

deionized water or water of comparable purity are used in the analysis.

3.1 Sodium carbonate. industrial pure, powdery.

3.2 Lead oxide. industrial pure, powdery (gold mass fraction <= 0.05µg/g;

silver mass fraction <= 5µg/g).

3.3 Borax. powdery.

3.4 Starch. industrial pure, powdery.

3.5 Silicon dioxide. industrial pure, powdery.

3.6 Sodium chloride. industrial pure, powdery.

3.7 Gold (mass fraction >= 99.99%).

3.8 Silver (mass fraction >= 99.99%).

3.9 Copper (mass fraction >= 99.95%).

3.10 Sulfuric acid (rho1.84g/mL).

3.11 Nitric acid (1+1).

3.12 Nitric acid (1+7).

3.13 Mercuric sulfate solution (23g/L).

3.14 Sodium chloride solution (10g/L).

3.15 Acetic acid (1+3).

4 Instruments and equipment

4.1 Balance.

4.1.1 Ultra-micro balance. with a sensitivity of 0.001mg.
4.1.2 Microbalance. with a sensitivity of 0.01mg.
4.1.3 Analytical balance. with a sensitivity of 1mg.
4.1.4 Counter balance. with a sensitivity of 1g.

4.2 Assay furnace.

4.3 Cupel machine.

4.4 Porcelain crucible. low profile, 30mL.

4.5 Clay crucible. with a height of 120mm, an upper outer diameter of 90mm,

and a lower outer diameter of 50mm.

4.6 Cupel. Ash cement cupel or magnesia cupel.

General specifications. with a height of 30mm, an upper inner diameter of

35mm, a lower outer diameter of 40mm, and a depth of 17mm or so.

5 Analytical procedure

5.1 Specimen

5.3.1.3 TRANSFER all sediments to the filter paper. USE warm water to

wash the sediments until there is no blue color. PLACE the glass rod and filter

paper on the cup wall, together with the filter paper loaded with the sediments,

in a clay crucible, and then PLACE it in an assay furnace. RISE from room

temperature to about 500°C for ashing until ashing is completed.

5.3.2 Ingredients

COOL the clay crucible containing the ash compound to room temperature.

ADD 20g of sodium carbonate (3.1), 60g of lead oxide (3.2), 7g of borax (3.3),

7g of silicon dioxide (3.5), and 3g of starch (3.4). STIR well, and COVER

10mm thick sodium chloride (3.6).

5.3.3 Melting

PLACE the prepared clay crucible in an assay furnace at 800°C. RISE

temperature to 1,100°C within 30min to 40min, and INSULATE for 15min

(total melting time is 45min to 55min) before discharging. POUR the melt into

a preheated and oiled cast iron mold. After cooling, BEAT the lead buckle into

a square shape. COLLECT the slag into the original clay crucible for later use

(corrected by the method B).

5.3.4 Cupellation
5.3.4.1 PLACE the lead buckle in a cupel preheated in an assay furnace at

900°C for 20min, and CLOSE the furnace door. After the floating film on the

surface of the lead liquid disappears (uncoating), slightly OPEN the furnace

door to lower the furnace temperature to 840°C to 860°C for cupellation. The

cupellation ends when the particles appear to flash. MOVE the cupel to the

furnace door, and PLACE it in a cupel tray after slight cooling.

5.3.4.2 USE a small tweezers to remove the gold and silver particles from

the cupel. PLACE them in a porcelain crucible, and ADD 15mL of acetic acid

(3.15). REMOVE when boiled to about 5mL on an electric hot plate. WASH

with warm water three times, and DISCARD the cleansing solution. PLACE

the gold and silver particles retained in the porcelain crucible on a

high-temperature electric furnace to bake dry, REMOVE and WEIGH

(accurate to 0.01mg) after cooling to room temperature. KEEP the cupel for

later use (corrected by the method B).

5.3.5 Parting

PLACE the weighed gold and silver particles on a small steel anvil to beat into

a sheet. PLACE it in a porcelain crucible. ADD about 5mL of hot nitric acid

(3.12). PLACE it on a low-temperature heating plate for parting. When

steaming to about 2mL, ADD about 5mL of hot nitric acid (3.11). STEAM to

about 2mL, REMOVE, COOL, and WASH three times with hot water. PLACE

m12 - Gold content measured in the second correction, in milligrams (mg);

m13 - Blank content of gold in the total content of lead oxide used in the

ingredients in the absence and presence of correction, in milligrams (mg);

m4 - Content of gold and silver particles measured in the absence of

correction, in milligrams (mg);

m15 - Content of gold and silver particles measured in the first correction, in

milligrams (mg);

m16 - Content of gold and silver particles measured in the second correction,

in milligrams (mg);

m14 - Blank content of silver in the total content of lead oxide used in the

ingredients in the absence and presence of correction, in milligrams (mg);

m0 - Mass of specimen, in grams (g).

The resulting gold content is expressed to one decimal place; and the silver

content is expressed to the integer position.

7 Precision

7.1 Repeatability

The measured values of the two independent test results obtained under the

repeatability conditions are within the range of average values given below.

The absolute difference between the two test results does not exceed the

repeatability limit (r). The case of exceeding the repeatability limit (r) does not

exceed 5%. The repeatability limit (r) is obtained by linear interpolation

according to the data in Table 2.

Table 2 -- Repeatability

Gold mass fraction/(g/t) 9.2 29.9 59.9 100.2 141.4 190.5

Repeatability limit (r)/(g/t) 0.8 1.5 2.2 3.0 3.5 4.0

Silver mass fraction/(g/t) 18 113 505 1017 1962 3098 4154

Repeatability limit (r)/(g/t) 6 15 35 50 70 95 115

NOTE. When the gold mass fraction is 0.5g/t, and the repeatability limit (r) is 0.2g/t.

7.2 Reproducibility

The measured values of the two independent test results obtained under the

reproducibility conditions are within the range of average values given below.

The absolute difference between the two test results does not exceed the

reproducibility limit (R). The case of exceeding the reproducibility limit (R)

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

How to Download YS/T 521.2-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 521.2-2009

$125.00