YS/T 520.11-2007Chemical analysis of gallium. Part 11: Determination of mercury content. The cold vapor atomic absorption spectral method (English PDF)
镓化学分析方法 第11部分:汞含量的测定冷原子吸收光谱法
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for YS/T 520.11-2007 in 30 minutes.
Issued by
National Development and Reform Commission
Level / Type
National · Recommended
Issue date
November 14, 2007
Implementation date
May 1, 2008
Scope
YS/T 520.11-2007 is the English-translated version of 镓化学分析方法 第11部分:汞含量的测定冷原子吸收光谱法.
YS/T 520.11-2007 — This section provides the determination of gallium mercury content. This section applies to the determination of gallium mercury content. Measurement range. ~ 0.00002% 0.00010%.
Found what you need?
Document preview — YS/T 520.11-2007
National Standard of the People's Republic of China
- ICS
- 77.120.70
- Classification
- H 14
- Replacing
- YS/T 520.11-2006
Issued by: National Development and Reform Commission
Contents
- Foreword
- 1 Scope
- 2 Method summary
- 3 Reagents
- 3.1 Nitric acid, pure class distinctions (rho1.42g/cm
- 4 Instruments and apparatus
Foreword
YS/T 520-2007 "Chemical analysis of gallium" Is the YS/T 520-2006 (formerly GB/T 4375-1984) amendments, divided into Part 12.
--- Part 1. Determination of copper content of 2,9-dimethyl-4,7-diphenyl-1,10-phenanthroline spectrophotometry
--- Part 2. Determination of lead content of 4- (2-pyridyl) - resorcinol spectrophotometry
--- Part 3. Determination of aluminum content Chromazurol S- tetradecyl pyridine bromide spectrophotometric method
--- Part 4. Determination of iron content of 4,7-diphenyl-1,10-phenanthroline spectrophotometry
--- Part 5. Determination of calcium content nitrous oxide - acetylene flame atomic absorption spectrometry
--- Part 6. Determination of tin content salicylfluorone - cetyl trimethyl ammonium bromide, spectrophotometry
--- Part 7. Determination of silicon content extraction - molybdenum blue spectrophotometric method
--- Part 8. Determination of indium content of ethyl violet spectrophotometry
--- Part 9. Determination of germanium content Phenylfluorone - polyethylene glycol octyl phenyl ether extraction spectrophotometric method
--- Part 10. Determination of zinc content atomic absorption spectrometry
--- Part 11. Determination of mercury content of the cold atomic absorption spectrometry
--- Part 12. lead, copper, nickel, aluminum, indium and zinc Determination of chemical spectroscopy this is Part 11.
The partial replacement of YS/T 520.11-2006 (formerly GB/T 4375.11-1984).
This part is YS/T 520.11-2006 "Determination of cold Chemical analysis of gallium Part 11 of mercury content by atomic absorption spectrometry Law "editorial finishing.
The non-ferrous metal part by the National Standardization Technical Committee and centralized.
This standard by the Aluminum Corporation of China Shandong branch responsible for drafting.
This section drafters. Zhang Xinyu, Liu Yulong.
The non-ferrous metal part by the National Standardization Technical Committee responsible for the interpretation.
This part of the standard replaces the previous editions are.
--- YS/T 520.11-2006 (formerly GB/T 4375.11-1984).
Chemical analysis of gallium Part 11. Determination of mercury content Cold vapor atomic absorption spectrometry
1 Scope
This section provides the determination of gallium mercury content.
This section applies to the determination of gallium mercury content. Measurement range. ~ 0.00002% 0.00010%.
2 Method summary
Sample was dissolved in nitric acid, sulfuric acid. Stannous chloride as a reducing agent, using air as a carrier gas, and the resulting mercury vapor atomic mercury vapor measured Import Meter were measured.
3 Reagents
3.1 Nitric acid, pure class distinctions (rho1.42g/cm
3.2 sulfuric acid, pure class distinctions (1 + 1).
3.3 sulfuric acid, pure class distinctions (1 + 35).
3.4 stannous chloride solution (10%). Weigh 10g of stannous chloride (SnCl2 · 2H2O) was dissolved in 100mL of hydrochloric acid (1 + 1). time cost Now equipped.
3.5 Storage mercury standard solution. Weigh 1.0000g pure mercury spectrum [(Hg) >=99.99%], placed in 250mL beaker, add 20mL ~ 30mL of nitric acid (1 + 1), the hood to slowly dissolved by heating, to be dissolved completely after dilution with water, transferred to 1000mL capacity Flask and dilute with water to volume, and mix. This solution 1mL containing 1.0mg of mercury.
3.6 mercury standard solution. Pipette 10.00mL mercury standard stock solution (3.5), placed in 100mL flask, nitric acid is added 1mL (3.1), dilute to the mark and mix. This solution 1mL containing 100µg mercury.
3.7 mercury standard solution. Pipette 10.00mL mercury standard solution (3.6), placed in 100mL flask, add 1mL of nitric acid (3.1), with Dilute with water to volume, and mix. This solution 1mL containing 10µg mercury.
3.8 mercury standard solution. Pipette 10.00mL mercury standard solution (3.7), placed in 100mL flask, add 1mL of nitric acid (3.1), with Dilute with water to volume, and mix. This solution 1mL containing 1µg mercury.
3.9 Compressed air (cylinders loaded, or produced by the air compressor).
4 Instruments and apparatus
Mercury vapor meter and ancillary equipment is shown in Figure 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
How to Download YS/T 520.11-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 520.1-2007 — Chemical analysis of gallium. Part 1: Determination of copper content. The 2, 9-dimethy-4, 7-diphenyl-1, 10-phenanthroline spectrophotometric method
YS/T 520.10-2007 — Chemical analysis of gallium. Part 10: Determination of zine content. The atomic absorption spectral method
YS/T 520.12-2007 — Chemical analysis of gallium. Part 12: Determination of lead, coper, nickel, aluminum, indium and zinc content. The spectrochemical method
Secure payment via Stripe
Payments accepted
YS/T 520.11-2007
$184.00