Valid

YS/T 461.12-2016Methods for chemical analysis of lead and zinc bulk concentrates--Part 12: Determination of thallium content--Inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry (English PDF)

混合铅锌精矿化学分析方法 第12部分:铊量的测定 电感耦合等离子体质谱法和电感耦合等离子体原子发射光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for YS/T 461.12-2016 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

July 11, 2016

Implementation date

January 1, 2017

Scope

YS/T 461.12-2016 is the English-translated version of 混合铅锌精矿化学分析方法 第12部分:铊量的测定 电感耦合等离子体质谱法和电感耦合等离子体原子发射光谱法.

YS/T 461.12-2016 — This part of YS/T 461 specifies the method for the determination of thallium in mixed lead-zinc concentrates. This part is applicable to the determination of thallium in mixed lead and zinc concentrates.

Method 1 has a measurement range of 0.000050% to 0.010%; Method 2 is measured the range is 0.0050% ~ 0.10%. Section 1 Scope Cross Section Method 1 is an arbitration method.

Found what you need?

Document preview — YS/T 461.12-2016

National Standard of the People's Republic of China

ICS
77.120.60
Classification
H 13

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Method 1 Inductively Coupled Plasma Mass Spectrometry
  • 2.1 Method Summary
  • 2.2 Reagents
  • 2.3 Instruments
  • 2.4 Sample

Foreword

YS/T 461 "mixed lead and zinc concentrate chemical analysis method" is divided into 12 parts.

- Part 1. Determination of lead content and zinc content - Separation of Na2EDTA titration;

- Part 2. Determination of iron content - Na2EDTA titration;

- Part 3. Determination of sulfur content - Combustion - neutralization titration;

- Part 4. Determination of arsenic iodine titration;

- Part 5. Determination of the amount of silica - Molybdenum blue spectrophotometric method;

- Part 6. Determination of mercury content - Atomic fluorescence spectrometry;

- Part 7. Determination of cadmium content - Flame atomic absorption spectrometric method;

- Part 8. Determination of copper content - Flame atomic absorption spectrometric method;

- Part 9. Determination of silver content - Flame atomic absorption spectrometric method;

- Part 10. Determination of gold and silver;

- Part 11. Determination of arsenic, bismuth, cadmium, cobalt, copper, nickel and antimony - Inductively coupled plasma - atomic emission spectrometry;

Part 12. Determination of thallium content - Inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry.

This part is part 12 of YS/T 461.

This part is drafted in accordance with the rules given in GB/T 1.1-2009.

This part of the National Nonferrous Metals Standardization Technical Committee (SAC/TC243) proposed and centralized.

The main method of this part of the main drafting unit. Shenzhen Jinling South Nonferrous Metals Co., Ltd. Shaoguan smelter, Shaoguan quality measurement Supervisor.

Part 2 Method 2 Main Drafting Unit. Fangchenggang Entry-Exit Inspection and Quarantine Bureau.

This part participates in the drafting unit. Beijing Mining and Metallurgy Research Institute, China Nonferrous Guilin Mineral Geology Research Institute Co., Ltd., Zijin Mining Group Co., Ltd., Ningbo Entry-Exit Inspection and Quarantine Bureau Technology Center, Kunming Metallurgical Research Institute.

The main method of this part of the main drafters. Yuan Qi, Zhang Xiaojun, Shi Shilong, Zhu Ling, Liu Runting, Su Chunfeng, the ancient line, Tang Biyu, Luo Wen, Xie Wenliang, Shi Honglan, Zhu Xiaoyan, Li Chao, Liu Weili.

This part of the method 2 main drafters. Luo Minggui, Li Xiangrong, Chen Zhipeng, Su Chunfeng, Qiu Li, Wang Jiangliang, Luo Wen, Yu Jinsheng, Yang Jianbing, Huang Zufei, Shi Honglan, Cao Guozhou.

Chemical Analysis of Mixed Lead - Zinc Concentrate Part 12. determination of thallium content Inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry

1 Scope

This part of YS/T 461 specifies the method for the determination of thallium in mixed lead-zinc concentrates.

This part is applicable to the determination of thallium in mixed lead and zinc concentrates. Method 1 has a measurement range of 0.000050% to 0.010%; Method 2 is measured the range is 0.0050% ~ 0.10%. Section 1 Scope Cross Section Method 1 is an arbitration method.

2 Method 1 Inductively Coupled Plasma Mass Spectrometry

2.1 Method Summary

The samples were decomposed by hydrochloric acid, nitric acid and sulfuric acid. The samples were measured on an inductively coupled plasma mass spectrometer with 193Ir as internal standard.

Calculate the amount of thallium in the sample.

2.2 Reagents

In the analysis only use identified as excellent grade pure reagent, the water used as a water.

2.2.1 Hydrochloric acid (rho1.19g/mL).

2.2.2 nitric acid (rho1.42g/mL).

2.2.3 sulfuric acid (rho1.84g/mL).

2.2.4 nitric acid (1 1).

2.2.5 nitric acid sulfuric acid mixed acid (1 1). 500mL nitric acid (2.2.2) while stirring 500mL sulfuric acid (2.2.3), after cooling use.

2.2.6 Thallium standard storage solution. Weigh 0.2795g thallium oxide (wTl2O3 > 99.99%) placed in.200mL beaker, cover dish, Slowly add 25mL nitric acid (2.2.4) dissolved at low temperature, drive out the nitrogen oxide, remove and cool to room temperature, wash the dish and cup wall with water, 250mL volumetric flask, diluted with water to the mark, mix. This solution 1mL containing 1mg thallium.

2.2.6.1 Thallium standard solution A. Thallium standard storage solution (2.2.6) diluted to thallium concentration of 100ng/mL, 2% nitric acid as the medium.

2.2.6.2 thallium standard solution B. thallium standard solution A diluted to thallium concentration of 10ng/mL, 2% nitric acid as the medium.

2.2.7 internal standard solution. 10µg/L193Ir solution, with 2% nitric acid as the medium.

2.2.8 argon. wAr >= 99.996%.

2.3 Instruments

Inductively coupled plasma mass spectrometer. resolution 0.1amu ~ 1amu; 205Tl isotope response value > 105.

2.4 Sample

2.4.1 Specimens shall pass through 0.074mm sieve.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

How to Download YS/T 461.12-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 461.12-2016

$145.00