Valid

YS/T 38.1-2009Chemical analysis methods of high pure gallium. Part 1: Determination of silicon content. Molybdenum blue spectrophotometry (English PDF)

高纯镓化学分析方法 第1部分:硅量的测定钼蓝分光光度法

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for YS/T 38.1-2009 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

December 4, 2009

Implementation date

June 1, 2010

Scope

YS/T 38.1-2009 is the English-translated version of 高纯镓化学分析方法 第1部分:硅量的测定钼蓝分光光度法.

YS/T 38.1-2009 — YS/T of the provisions of section 38 of the method for the determination of silicon content in high purity gallium. This section applies to gallium (99.9999%) Determination of silicon content. Measurement range from 0.00001% to 0.00005%.

Found what you need?

Document preview — YS/T 38.1-2009

National Standard of the People's Republic of China

ICS
77.040.30
Classification
H 12
Replacing
YS/T 38.1-1992

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument
  • 5 Step, Analysis
  • 5.1 Sample
  • 5.3 Blank test

Foreword

YS/T 38 "high purity gallium chemical analysis method" is divided into two parts.

--- Part 1. "Chemical analysis of gallium high-purity silicon content - Molybdenum blue spectrophotometric method";

--- Part 2. "high purity gallium chemical analysis of magnesium, titanium, chromium, manganese, nickel, cobalt, copper, zinc, cadmium, tin, lead, bismuth content - Inductively Coupled Plasma Mass Spectrometry. " this section YS/T 38 - Part 1.

The partial replacement of YS/T 38.1-1992 "purity gallium chemical analysis of molybdenum blue spectrophotometric method for determination of silicon content." this section compared with YS/T 38.1-1992, have the following main changes.

--- The original method of presentation format has been modified.

The non-ferrous metal part by the National Standardization Technical Committee and centralized.

This section is responsible for drafting unit. Beijing Nonferrous Metal Research Institute.

Participated in the drafting of this section. Zhuzhou Smelter Group, Emei Semiconductor plant.

1 Scope

YS/T of the provisions of section 38 of the method for the determination of silicon content in high purity gallium.

This section applies to gallium (99.9999%) Determination of silicon content. Measurement range from 0.00001% to 0.00005%.

2 Method summary

Sample decomposition with hydrochloric acid gas at about 200 °C volatile separation of gallium trichloride; hydrofluoric acid solution polymerization of silicic acid, boric acid complex fluoride ions;

Silicon molybdenum blue method in a spectrophotometer absorbance was measured at a wavelength of 810nm.

3 Reagents

The water in this portion of deionized water (resistivity greater than 15Mohm · cm).

3.1 hydrochloride (rho1.19g/mL).

3.2 sulfate (rho1.84g/mL), pure class distinctions.

3.3 sulfate (35 + 1), the preparation of sulfuric acid (3.2).

3.4 sulfate (1 + 1), the preparation of sulfuric acid (3.2).

3.5 HF. hydrofluoric acid (excellent pure) platinum by distillation was purified by distillation or polytetrafluoroethylene sub-boiling distillation purified by distillation.

3.6 boric acid (40g/L), pure class distinctions.

3.7 Ammonium molybdate (50g/L), high purity.

3.8 tartaric acid (30%), pure class distinctions.

3.9 reducing agent. 1-amino-2-naphthol -4-2- acid (2mg/mL).

Silicon 3.10 Standard stock solution. Weigh 0.2139g silicon dioxide were placed in a platinum crucible, sodium carbonate and potassium carbonate was added 2g (2.1) mixed Co-reagent, stir melted until clear. After cooling, transferred to 1000mL volumetric flask, dilute to the mark, mix, immediately go to a plastic bottle in. This solution 1mL containing 100µg silicon.

3.11 Silicon standard solution. Pipette 10.0mL silicon standard stock solution (3.10) into 1000mL volumetric flask, dilute to the mark with water, mix Uniform, immediately go to a plastic bottle. This solution 1mL containing 1µg silicon.

4 Instrument

4.1 Spectrophotometer.

4.2 gallium separation means.

5 Step, Analysis

5.1 Sample

Weigh 1g sample, accurate to 0.0001g.

5.2 Determination of the number of Three independently measured sample and averaged.

5.3 Blank test

Along with sample blank test.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

How to Download YS/T 38.1-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 38.1-2009

$85.00