YS/T 368-2015Test method of thermo-emf for noble metal thermocouple wires. Fuse wire (English PDF)
贵金属热电偶丝材热电动势的测量方法熔丝法
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for YS/T 368-2015 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
April 30, 2015
Implementation date
October 1, 2015
Scope
YS/T 368-2015 is the English-translated version of 贵金属热电偶丝材热电动势的测量方法熔丝法.
YS/T 368-2015 — This standard specifies the method by measuring the fuse wire thermocouple precious metal gold (1064.18 °C), palladium (1554.8 °C), platinum (1773 °C) Melting Point of thermal EMF method.
This standard applies to measuring the diameter in the range of 0.3mm ~ 1.0mm precious metal thermocouple wire, thermocouple wire and other sizes in Thermal EMF measurements of each pure metal melting point may also be referring to.
Found what you need?
Document preview — YS/T 368-2015
National Standard of the People's Republic of China
- ICS
- 77.120.99
- Classification
- H 68
- Replacing
- YS/T 368-1994
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Method summary
- 5 Test instruments, equipment and materials
- 5.1 Test instruments and equipment
- 5.2 Material
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
Instead of the standard YS/T 368-1994 "precious metal thermocouple wire fuse thermal EMF measurement method." This standard with the original standard Quasi compared to the main changes are as follows.
--- Increased terminology, which uses JB/T 6819.2 "Instrument Material term temperature material" terms and definitions;
--- Modify the accuracy of the test equipment;
--- Modify the purity fuses and treatment methods;
--- Modify the preparation of samples;
--- Refinement of the measurement process control;
--- Joined the fuse and common measurement system of FIG precious metal thermocouple wire energized annealing method;
--- According to GB/T 18035 modified representation dual wire grades.
This standard by the national non-ferrous metals Standardization Technical Committee (SAC/TC243) and focal points.
This standard was drafted. Your research Platinum Ltd., China Nonferrous Metals Industry Standards and Metrology Institute for Quality.
Drafters of this standard. Wu Fei, Zhu Wuxun to Lei, Liu Yi, Feng Yan, Huang Shaohua, Zhang Xiaobo.
This standard replaces the standards previously issued as follows.
--- YS/T 368-1994;
--- YB/T 933-1978.
Thermal precious metal thermocouple wire EMF measurements fuse Act
1 Scope
This standard specifies the method by measuring the fuse wire thermocouple precious metal gold (1064.18 °C), palladium (1554.8 °C), platinum (1773 °C) Melting Point of thermal EMF method.
This standard applies to measuring the diameter in the range of 0.3mm ~ 1.0mm precious metal thermocouple wire, thermocouple wire and other sizes in Thermal EMF measurements of each pure metal melting point may also be referring to.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 8170 repair value expressed about the rules and limit values and judgment GB/T 18035-2000 Method of precious metals and their alloys JB/T 6819.2 meter material term temperature materials
3 Terms and Definitions
Terms and definitions JB/T 6819.2 defined apply to this document.
4 Method summary
According to a pure metal melting temperature constant and thermocouple intermediate metal law, with a small amount of pure gold, palladium or platinum wire wound around the wire measured hot Measuring end galvanic, heated to the melting temperature plateau appears, the measured value of the measured thermocouple thermal emf in the melting temperature of the floor, taking the average as measured the amount of results.
5 Test instruments, equipment and materials
5.1 Test instruments and equipment
5.1.1 Low potential DC potentiometer. Accuracy of not less than 0.01 and its corresponding supporting devices, or other equivalent electrically similar accuracy Measuring equipment.
5.1.2 high-temperature test furnace. length of about 500mm, maximum temperature up to 1800 °C; the best test furnace hot zone off-center position should not exceed 20mm, its average temperature zone length should be 10mm ~ 15mm, the temperature difference should not exceed ± 1 °C.
5.1.3 thermocouple wire annealing apparatus energized. power supply unit should be equipped with an accuracy of not less than 0.5 meter AC current governor and the like.
5.1.4 freezing thermostat. with crushed ice mixed with water to make the thermostat effective depth should be more than 300mm.
5.2 Material
5.2.1 Fuse. gold, palladium, platinum fuse purity >=99.99%, phi0.2mm ~ 0.3mm, fully clean, soft annealed state.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
Referenced standards
How to Download YS/T 368-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 18035-2000 — Precious metals and its alloys designation system
GB/T 8170-2008 — Rules of rounding off for numerical values & expression and judgement of limiting values
JB/T 6819.2-1993 — Terminology of instrument materials - Temperature measuring materials
Secure payment via Stripe
Payments accepted
YS/T 368-2015
$90.00