YS/T 34.3-2011Method for chemical analysis of the high-purity arsenic. Predicating method for determinating the concentration of sulfur (English PDF)
高纯砷化学分析方法极谱法测定硫量
This is a limited preview
Buy now to download the full PDF (5 pages)
Need quotation for your management?
Get a formal quotation for YS/T 34.3-2011 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
December 20, 2011
Implementation date
July 1, 2012
Scope
YS/T 34.3-2011 is the English-translated version of 高纯砷化学分析方法极谱法测定硫量.
YS/T 34.3-2011 — YS/T of the provisions of section 34 of the method for the determination of arsenic in high purity sulfur content. This section applies to the determination of arsenic (99.999%) sulfur content. Measurement range 0.00003% 0.00015%.
Found what you need?
Document preview — YS/T 34.3-2011
National Standard of the People's Republic of China
- ICS
- 77.040.30
- Classification
- H 17
- Replacing
- YS/T 34.4-1992
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Method summary
- 3 Reagent standard solution
- 4.1 Oscilloscope Polarograph
Foreword
YS/T 34 "high-purity arsenic chemical analysis method" consists of three parts.
--- Part 1. Methods for chemical analysis of high-purity arsenic by inductively coupled plasma mass spectrometry (ICP-MS) Determination of impurities in high-purity arsenic content;
--- Part 2. Determination of the amount of high-purity arsenic and selenium chemical analysis of polarography;
--- Part 3. Determination of the amount of high-purity arsenic and sulfur chemical analysis of polarography.
This section is YS/T Part 3 34.
The partial replacement of YS/T 34.4-1992 "determination of sulfur high-purity arsenic chemical analysis of polarography." this section according to GB/T 1.1-2009. the preparation of "Standardization Guide Part 1 standard structure and writing" requirement.
The non-ferrous metal part by the National Standardization Technical Committee.
This section is responsible for drafting unit. Emei Semiconductor Material Factory.
1 Scope
YS/T of the provisions of section 34 of the method for the determination of arsenic in high purity sulfur content.
This section applies to the determination of arsenic (99.999%) sulfur content. Measurement range 0.00003% 0.00015%.
2 Method summary
Samples with hydrochloric acid - nitric acid dissolved, evaporated to dryness. Join hydrobromide, 120 °C heating volatile arsenic removal. Hydrochloric acid, hydroiodic acid, mixed sodium hypophosphite Was reducing sulfur impurities to produce hydrogen sulfide. -EDTA Absorb sodium hydroxide solution, oscillopolarographic determination.
3 Reagent standard solution
3.1 deionized water (resistivity greater than 15Mohm · cm).
3.2 HCl. 1000mL high purity hydrochloric acid (rho1.19g/mL), was added 0.4g two barium chloride, after sub-boiling distillation of use.
Nitrate 3.3. 1000mL high purity nitric acid (rho1.42g/mL), 0.4g of barium nitrate was added, after azeotropic distillation using ethylene.
3.4 hydrobromide. 500mL high purity hydrobromic acid (40%), placed in the reflux flask, 20g sodium hypophosphite (NaH2PO3 · H2O), to 2L/min ~ 3L/min of pure argon a rate of (3.10), the solution was heated, kept boiling, the reflux 4h. Back distillate further sub-boiling distillation, abandoned Head to 150mL distillate collecting 250mL fractions spare. Hydrobromide concentration should not be less than 8.4mol/L.
-EDTA 3.5 Sodium hydroxide absorption solution. Pipette 40.0mL ~ 45.0mL high purity sodium hydroxide solution (40%), 5.0mLEDTA Solution (0.5mol/L), placed in 500mL volumetric flask, dilute to the mark, mix and transferred to a polyethylene bottle save. This hydroxide solution Sodium concentration and the concentration of EDTA were 1mol/L, 0.01mol/L.
Note. Commercially available high-purity sodium hydroxide solution (40%) after calibration use.
3.6 reducing agent (I). Pipette 400mL hydroiodic acid (45%), 210mL of hydrochloric acid (rho1.19g/mL), 120g sodium hypophosphite into the reflux Bottle with 2L/min of pure argon a rate of (3.10), maintained at boiling heat (approximately 114 deg.] C), the reflux 5h. Cooling to room temperature, transferred to a quartz flask, Store in a cool place (effectively a half months). Boiling water bath heated to dissolve salt use.
3.7 reducing agent (II). Pipette 250mL hydroiodic acid (45%), 60mL acetic acid, 50g sodium hypophosphite, placed in the reflux flask, to 2L/min of pure argon through rate (3.10), heated and maintained boiling (about 118 °C), the reflux 4h, stored in a cool place (within a half months valid).
3.8 sodium sulfate solution. Accurately weigh 4.431g sodium (105 °C after drying), placed 1000mL volumetric flask, add 50mL salt Acid (rho1.19g/mL), sodium sulfate dissolved, diluted with water to volume, and mix. This solution 1mL 1mg containing sulfur.
3.9 sulfur standard solution. accurate Pipette 1.0mL sodium sulfate solution (3.8), placed 1000mL volumetric flask, dilute to the mark with water, mix uniform. This solution 1mL containing 1µg sulfur.
3.10 pure argon or nitrogen. > 99.9%.
4-volatile devices and instruments
4.1 Oscilloscope Polarograph
Scanning voltage range 0V ~ 2V.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
How to Download YS/T 34.3-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 34.1-2011 — Method for chemical analysis of the high-purity arsenic. Inductive coupling plasma mass spectrum(ICP-MS) for determinating the concentration of elements in the high-purity arsenic
YS/T 34.2-2011 — Method for chemical analysis of the high-purity arsenic. Predicating method for determinating the concentration of selenium
YS/T 1115.10-2026 — Chemical analysis methods of copper, lead and zinc ores and tailings - Part 10: Determination of gold, silver, molybdenum, arsenic, tungsten, bismuth, gallium, indium, thallium, selenium, tellurium and germanium contents - Inductively coupled plasma mass spectrometry
Secure payment via Stripe
Payments accepted
YS/T 34.3-2011
$105.00