Valid

YS/T 325.2-2009Methods for chemical analysis of nickel-copper alloy. Part 2: Determination of copper content. Electrolysis weight method (English PDF)

镍铜合金化学分析方法 第2部分:铜量的测定 电解重量法

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for YS/T 325.2-2009 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

December 4, 2009

Implementation date

June 1, 2010

Scope

YS/T 325.2-2009 is the English-translated version of 镍铜合金化学分析方法 第2部分:铜量的测定 电解重量法.

YS/T 325.2-2009 — YS/T in this part 325 specifies the method for determination of nickel-copper alloy of copper content. This section applies to the determination of nickel-copper alloy of copper content. Measurement range. 15.00% - 50.00%.

Found what you need?

Document preview — YS/T 325.2-2009

National Standard of the People's Republic of China

ICS
77.120.40
Classification
H 13
Replacing
YS/T 325-1994

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Principle of the method
  • 3 Reagents
  • 4 Instrument

Foreword

YS/T 325-2009 "nickel-copper alloy chemical analysis method" a total of six sections.

--- Part 1. Determination of nickel content Na2EDTA titration

--- Part 2. Determination of copper content - Gravimetric method electrolysis

--- Part 3. Determination of iron content by flame atomic absorption spectrometry

--- Part 4. Determination of manganese content by flame atomic absorption spectrometry

--- Part 5. Determination of aluminum content Na2EDTA titration

--- Part 6. Determination of titanium content security for DAM spectrophotometry this section YS/T Part 2 325.

The partial replacement of YS/T 325-1994 Determination of copper content in "nickel-copper alloy (NCu28-2.5-1.5) Methods for chemical analysis." this section compared with YS/T 325-1994, the main changes are as follows.

--- Specifies the determination of the scope of the method.

--- The sample was dissolved nitrate - mixed sulfuric acid, nitric acid instead - hydrofluoric acid.

--- Increase the determination of residual copper content, incorporation assay results.

--- Supplementary terms of quality assurance and control, increased precision terms.

The non-ferrous metal part by the National Standardization Technical Committee and centralized.

This section is responsible for drafting unit. aluminum Shenyang Nonferrous Metals Processing Co., Ltd.

Participated in the drafting of this section. Guangzhou Nonferrous Metal Research Institute, Ltd. high-tech copper sheets.

1 Scope

YS/T in this part 325 specifies the method for determination of nickel-copper alloy of copper content.

This section applies to the determination of nickel-copper alloy of copper content. Measurement range. 15.00% - 50.00%.

2 Principle of the method

Sample dissolved in nitric acid and hydrofluoric acid, the hydrogen peroxide reduction of nitrogen oxides electrodeposited copper. Join the platinum anode lead losses Reduce to a minimum, the electrolytic copper deposited on the platinum cathode, dried and weighed. The amount of residual copper electrolyte by atomic absorption spectrometry.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.

3.1 ethanol.

3.2 Hydrofluoric acid (rho1.13g/mL).

3.3 nitric acid (1 + 1).

3.4 Hydrogen peroxide (1 + 9).

3.5 ammonium chloride solution (0.02g/L).

3.6 lead nitrate solution (10g/L).

3.7 copper standard stock solution. Weigh 1.0000g copper (mass fraction of copper >=99.99%), placed in 250mL beaker, add 40mL of nitric acid (3.3), cover sheet pan, heated until completely dissolved, boiled to remove nitrogen oxides, washed with water and dish table cup wall, cooling. Moved 1000mL volumetric flask, dilute with water to volume, and mix. 1mL solution containing 1mg of copper.

3.8 Copper Standard Solution. Pipette 10.00mL copper standard stock solution (3.7), placed in 500mL volumetric flask, 10mL of nitric acid was added Diluted (3.3) with water to volume, and mix. This solution 1mL containing 20µg copper.

4 Instrument

4.1 250mL teflon beaker.

4.2 pairs sectional polytetrafluoroethylene sheet pan.

4.3 with automatic stirring device and a precision DC ammeter, voltmeter electrolyzer.

4.4 platinum cathode. with a diameter of about 0.11mm ~ 0.12mm platinum wire, woven into 52 holes per square centimeter mesh screen made of mesh cylinder shape. See Figure 1.

4.5 platinum anode. spiral. See Figure 2.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

Referenced standards

How to Download YS/T 325.2-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 325.2-2009

$184.00