YS/T 3015.3-2013Methods for chemical analysis of gold-loaded carbon. Part3: Determinaiton of calcium and magnesium contents. Flame atomic absorption spectrometry (English PDF)
载金炭化学分析方法 第3部分:钙和镁量的测定火焰原子吸收光谱法
This is a limited preview
Buy now to download the full PDF (5 pages)
Need quotation for your management?
Get a formal quotation for YS/T 3015.3-2013 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
YS/T 3015.3-2013 is the English-translated version of 载金炭化学分析方法 第3部分:钙和镁量的测定火焰原子吸收光谱法.
YS/T 3015.3-2013 — This section YS/T 3015 specifies the method for determination of loaded carbon calcium and magnesium content. This section applies to the determination of gold contained in the carbon content of calcium and magnesium. Measurement range. 0.050% - 2.0% Ca; Mg 0.010% to 0.50%.
Found what you need?
Document preview — YS/T 3015.3-2013
National Standard of the People's Republic of China
- ICS
- 77.120.01
- Classification
- D 46
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Method summary
- 3 Reagents
- 4 Instrument
Foreword
YS/T 3015 "loaded carbon chemical analysis methods" is divided into four parts.
--- Part 1. Determination of moisture content of the dry weight method;
--- Part 2. Determination of copper and iron content by flame atomic absorption spectrometry;
--- Part 3. Determination of the amount of calcium and magnesium by flame atomic absorption spectrometry;
--- Part 4. Copper, iron, calcium and magnesium content - Inductively coupled plasma atomic emission spectrometry.
This section YS/T 3015 Part 3.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This part is proposed by the China Gold Association.
This part of the National Gold Standardization Technical Committee (SAC/TC379) centralized.
This section is drafted. Zijin Mining Group Co., Lingbao Gold Company Ltd., Changchun Gold Research Institute, Henan Zhongyuan Gold Smelter Co., Ltd., Shandong National Gold Corp..
1 Scope
This section YS/T 3015 specifies the method for determination of loaded carbon calcium and magnesium content.
This section applies to the determination of gold contained in the carbon content of calcium and magnesium. Measurement range. 0.050% - 2.0% Ca; Mg 0.010% to 0.50%.
2 Method summary
The sample was burning ashed with hydrochloric acid, nitric acid to dissolve the residue. In dilute hydrochloric acid medium, flame atomic absorption spectrometer wavelength 422.7nm and 285.2nm at using air - acetylene flame, were measured absorbance of calcium and magnesium, calcium calculated according to the standard curve and Magnesium content.
3 Reagents
Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.
3.1 hydrochloric acid (rho = 1.19g/mL).
3.2 hydrochloride (11).
3.3 hydrochloride (14).
3.4 nitric acid (rho = 1.42g/mL).
3.5 strontium chloride solution. Weigh 25g strontium chloride (SrCl2 · 6H2O) in 400mL beaker was added 200mL of water, stirring to dissolve and transferred to 500mL volumetric flask, dilute with water to volume, and mix.
3.6 lanthanum chloride solution. Weigh 50g of lanthanum chloride (LaCl3 · 7H2O) in 400mL beaker, 200mL of water, stirring to dissolve, move Into 500mL volumetric flask, dilute with water to volume, and mix.
3.7 Calcium standard stock solution. Weigh 2.4973g by 105 °C ~ 110 °C drying calcium carbonate (reference reagent) in 250mL beaker, Was added 50mL of hydrochloric acid (3.2), covered with a watch glass, low heat until completely dissolved, heating to boil 1min ~ 2min, removed and cooled to room temperature.
Moved into 1000mL volumetric flask, dilute to the mark, mix and store in a plastic bottle. 1mL solution containing 1mg calcium.
3.8 Magnesium standard stock solution. Weigh 1.6583g ignition at 800 °C to constant weight of magnesium oxide (reference reagent) in 250mL beaker, add Into 50mL of hydrochloric acid (3.2), covered with a watch glass, low heat until completely dissolved, remove the cooling to room temperature. Moved into 1000mL volumetric flask, Diluted with water to the mark, mix and store in a plastic bottle. This solution 1mL 1mg containing magnesium.
3.9 calcium, magnesium mixed standard solution. Pipette 25.00mL calcium standard stock solution (3.7) and magnesium 25.00mL standard stock solution (3.8) to 250mL flask, add 20mL of hydrochloric acid (3.3), dilute to the mark, mix and store in a plastic bottle. This solution containing 1mL 100µg calcium and magnesium.
4 Instrument
Atomic absorption spectrometer, with calcium and magnesium hollow cathode lamp hollow cathode lamp.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
How to Download YS/T 3015.3-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 3015.1-2013 — Methods for chemical analysis of gold-loaded carbon. Part1: Determination of moisture content. Desiccation gravimetric method
YS/T 3015.2-2013 — Methods for chemical analysis of gold-loaded carbon. Part 2: Determination of copper and iron contents. Flame atomic absorption spectrometry
YS/T 3015.4-2013 — Methods for chemical analysis of gold-loaded cabon. Part 4: Determination of copper, iron, calcium and magnesium contents. Inductively coupled plasma-atomic emission spectrometry
Secure payment via Stripe
Payments accepted
YS/T 3015.3-2013
$105.00