YS/T 273.15-2012Chemical analysis methods and physical properties of cryolite. Part 15: X-ray fluorescence spectrometric method for the determination of elements content using pressed powder tablets (English PDF)
Also coversYST273.15-2012
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for YS/T 273.15-2012 in 30 minutes.
Issued by
Ministry of Industry and Information Technology of the PRC
Level / Type
National · Recommended
Issue date
December 28, 2012
Implementation date
June 1, 2013
Scope
YS/T 273.15-2012 (Chemical analysis methods and physical properties of cryolite. Part 15: X-ray fluorescence spectrometric method for the determination of elements content using pressed powder tablets) is available as an English-translated PDF.
YS/T 273.15-2012 is the Chinese standard "Chemical analysis methods and physical properties of cryolite. Part 15: X-ray fluorescence spectrometric method for the determination of elements content using pressed powder tablets".
Its scope clause reads: This Part of YS/T 273 specifies the X-ray fluorescence spectrometric method for the determination of contents of fluorine, aluminum, sodium, silicon, iron, sulfur, phosphorus and calcium (respectively represented by F, Al, Na, SiO2, Fe2O3, SO42-, P2O5, CaO) and other elements in cryolite using pressed powder tables.
This Part is applicable to the determination of fluorine, aluminum, sodium, silicon, iron, sulfur, phosphorus, calcium and other elements in cryolite. The measurement range is shown in Table 1.
Its clauses include principle of method; reagents; instruments; specimens; analysis procedures; analysis results. It was issued by the Ministry of Industry and Information Technology of the PRC on 2012-12-28 and took effect on 2013-06-01.
Found what you need?
Document preview — YS/T 273.15-2012
National Standard of the People's Republic of China
- ICS
- 71.100.10
- Classification
- H 61
Issued by: Ministry of Industry and Information Technology of the PRC
Contents
- Foreword...3
- 1 Scope...5
- 2 Normative References...5
- 3 Principle of Method...5
- 4 Reagents...6
- 5 Instruments...6
- 6 Specimens...6
- 7 Analysis Procedures...6
- 8 Analysis Results...7
- 9 Precision...8
- 10 Quality Assurance and Control...9
1 Scope
This Part of YS/T 273 specifies the X-ray fluorescence spectrometric method for the determination of contents of fluorine, aluminum, sodium, silicon, iron, sulfur, phosphorus and calcium (respectively represented by F, Al, Na, SiO2, Fe2O3, SO42-, P2O5, CaO) and other elements in cryolite using pressed powder tables.
This Part is applicable to the determination of fluorine, aluminum, sodium, silicon, iron, sulfur, phosphorus, calcium and other elements in cryolite. The measurement range is shown in Table
1.
2 Normative References
The following documents are essential to the application of this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this
Document.
YS/T 273.13-2006 Chemical analysis methods and physical properties of cryolite - Part
13: Preparation and storage of test samples
3 Principle of Method
The test material and dispersant are mixed and ground in a certain proportion; and then pressed to form a sample tablet. Measurements are performed by an X-ray fluorescence spectrometer.
Calculate the content of each element in the specimen based on the calibration curve of the intensity of each element in the standard sample tablet.
4 Reagents
4.1 Acetone: Analytically pure.
4.2 Absolute ethanol: Analytically pure.
4.3 Boric acid: Analytically pure.
5 Instruments
5.1 Wavelength dispersive X-ray fluorescence spectrometer.
5.2 Vibrating grinding mill and tungsten carbide grinding disc: The mortar should be able to grind a specimen of about 30g.
5.3 Tablet machine and mold: The pressing thickness shall be at least 4mm; the pressure shall be about 35t; and the inner diameter of the mold shall match the X-fluorometer sample cup.
6 Specimens
The specimen shall meet the requirements of 3.3 in YS/T 273.13-2006.
7 Analysis Procedures
7.1 Number of measurements
The same specimen shall be measured twice independently and the average value shall be taken.
7.2 Preparation of specimen tablets
7.2.1 Mixing and grinding: Weigh about 10g of dry specimen and put it into a tungsten carbide grinding disc; add 10 drops of acetone (4.1) or absolute ethanol (4.2) to prevent the specimen from agglomerating; and grind it to less than 45µm with a vibrating mill.
7.2.2 Press tablet: Pour an appropriate amount of specimen (7.2.1) into the mold; edge it with boric acid; use a tablet machine to pressurize it to about 35t; and keep it for 30 s. After taking out the sample tablet and trim it, use the ear wash ball to blow off the attached powder sample;
and then measure it on an X-fluorometer. When measuring, only take the edge of the sample tablet to avoid contamination of the measurement surface.
NOTE 1: In order to eliminate particle effects to the greatest extent during tableting analysis, the sample preparation conditions shall be consistent with those used when establishing the calibration curve.
NOTE 2: The extruded sample tablet shall be smooth and strong; no powder shall fall off after trimming;
and boric acid shall not be mixed into the measurement surface, otherwise, it cannot be tested.
7.3 Calibration
7.3.1 Background correction: For constant elements, choose one or two backgrounds to
measure.
7.3.2 Instrument drift correction: Calibrate instrument drift by measuring and monitoring
samples.
7.3.3 Drawing of calibration curve
Preparation of calibration sample tablets: Select the cryolite standard sample as the calibration sample to draw the calibration curve. Each element shall have a standard series with a sufficient content range and a certain gradient. The preparation process shall be carried out according to
7.2.
7.4 Determination
7.4.1 Preheat the X-ray fluorescence instrument to make it stable; and adjust the tube voltage and tube current according to the X-ray tube model. Select the operating parameters according to the model of the X-ray fluorescence spectrometer.
7.4.2 Measure the monitoring sample: Set the name of the monitoring sample and measure the
X-ray intensity of the analyzed elements in the monitoring sample. The reference intensity of the analyzed elements in the monitoring sample shall be measured at the same start-up as the standard sample to ensure the effectiveness of drift correction.
7.4.3 Measure the unknown sample: Start the quantitative analysis program; measure the
monitoring sample; and perform instrument drift correction. Measure the standard samples prepared in the same batch as the unknown samples. Enter the name of the unknown sample;
measure the unknown sample; and the analysis results shall meet the repeatability requirements specified in Table 2.
8 Analysis Results
Based on the X-ray measurement intensity of the unknown sample, the results are calculated by computer software.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
Referenced standards
How to Download YS/T 273.15-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 273.13-2006 — Chemical analysis methods and physical properties of cryolite. Part 13: Preparation and storage of test samples
YS/T 273.1-2020 — Methods for chemical analysis and physical properties test of cryolite - Part 1: Determination of moisture content - Gravimetric method
YS/T 273.10-2006 — Chemical analysis methods and physical properties of cryolite. Part 10: Determination of alumina content by gravimetric method
Secure payment via Stripe
Payments accepted
YS/T 273.15-2012
$105.00