YS/T 119.12-2010Determination and calculation of heat balance of special equipments for alumina production. Part 12: Indirect heating desiliconizing system (English PDF)
氧化铝生产专用设备热平衡测定与计算方法 第12部分:间接加热脱硅系统
This is a limited preview
Buy now to download the full PDF (11 pages)
Need quotation for your management?
Get a formal quotation for YS/T 119.12-2010 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
November 22, 2010
Implementation date
March 1, 2011
Scope
YS/T 119.12-2010 is the English-translated version of 氧化铝生产专用设备热平衡测定与计算方法 第12部分:间接加热脱硅系统.
YS/T 119.12-2010 — YS/T 119 This part provides for alumina production (including sintering and joint law) crude was indirectly heated desilication system heat balance measurement Set and calculate the baseline measurement conditions, measurement items and measuring method of calculation.
This section applies to the production of alumina steam indirect heating thermal balance determination system and the continuous removal of silicon computing.
Found what you need?
Document preview — YS/T 119.12-2010
National Standard of the People's Republic of China
- ICS
- 13.030.20
- Classification
- H 92
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Thermal balance determination and calculation of the reference
- 2.1 Reference temperature
- 2.2 Reference pressure
- 2.3 Steam enthalpy unit conversion
- 2.4 Units
- 2.5 Determination of the scope and calculation of heat balance system
- 3 Status and process equipment
Foreword
YS/T 119 "equipment for the production of alumina Determination and calculation of heat balance," a total of 12 parts.
--- Part 1. clinker kiln system;
--- Part 2. roasting kiln system;
--- Part 3. vertical lime kiln;
--- Part 4. high pressure digestion system;
--- Part 5. evaporator;
--- Part 6. desilication system;
--- Part 7. melt the pipeline system;
--- Part 8. gas suspension calcination system;
--- Part 9. roaster fluidized systems;
--- Part 10. Plate falling film evaporator system;
--- Part 11. Single sleeve preheating - autoclave stripping system;
--- Part 12. desilication indirect heating system.
This is Part 12 YS/T 119's.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This standard by the national non-ferrous metals Standardization Technical Committee (SAC/TC243) centralized.
This section drafted by the Aluminum Corporation of China Henan Branch.
This part of the Aluminum Corporation of China Shandong Branch, China Guizhou branch Chalco, China Aluminum Co. has Limited Guangxi Branch participated in the drafting.
1 Scope
YS/T 119 This part provides for alumina production (including sintering and joint law) crude was indirectly heated desilication system heat balance measurement Set and calculate the baseline measurement conditions, measurement items and measuring method of calculation.
This section applies to the production of alumina steam indirect heating thermal balance determination system and the continuous removal of silicon computing.
2 Thermal balance determination and calculation of the reference
2.1 Reference temperature
Reference temperature using 0 °C.
2.2 Reference pressure
Reference pressure using 101325Pa.
2.3 Steam enthalpy unit conversion
Conversion card and Joule, using 1Cal = 4.1868J.
2.4 Units
Material balance and thermal balance 1m3 are calculated on the basis desiliconisation dope.
2.5 Determination of the scope and calculation of heat balance system
Heat balance measurement range and calculation system comprising. a multi-stage preheater, desilication machine, from the evaporator, condensed water tank insulation, and the buffer tank Line.
3 Status and process equipment
Content 3.1 condition of the test report 3.1.1 indicate the age of the equipment, characteristics and existing problems, and put into operation since the last overhaul or commissioning date.
3.1.2 Production and Equipment Overview
Production and equipment before the completion of a monthly average of three months before the test, the content and format of the report are shown in Table 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
How to Download YS/T 119.12-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 119.1-2008 — Determination and calculation of heat balance of special equipments for alumina production. Part 1: Clinder rotary kiln system
YS/T 119.10-2005 — Methods for determination and calculation of heat balance of special equipments for alumina production. Part 10: Plate falling-film evaporator system
YS/T 119.11-2005 — Methods for determination and calculation of heat balance of special equipments for alumina production. Part 11: Tube prepare-high pressure autoclave system
Secure payment via Stripe
Payments accepted
YS/T 119.12-2010
$424.00