YS/T 1158.3-2016Methods for chemical analysis of copper-indium-gallium-selenide target. Part 3: Determination of aluminum, iron, nickel, chromium, magnesium, lead, zinc, cadmium, cobalt, molybdenum, bariumcontent and manganese contents. Inductively coupled plasma mass sp (English PDF)
铜铟镓硒靶材化学分析方法 第3部分:铝、铁、镍、铬、锰、铅、 锌、镉、钴、钼、钡、镁量的测定 电感耦合等离子体质谱法
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for YS/T 1158.3-2016 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
July 11, 2016
Implementation date
January 1, 2017
Scope
YS/T 1158.3-2016 is the English-translated version of 铜铟镓硒靶材化学分析方法 第3部分:铝、铁、镍、铬、锰、铅、 锌、镉、钴、钼、钡、镁量的测定 电感耦合等离子体质谱法.
YS/T 1158.3-2016 — YS/T 1158 This section specifies the determination of aluminum, iron, nickel, chromium, manganese, lead, zinc, cadmium, cobalt, molybdenum, barium and magnesium in copper indium gallium selenium target.
This part is suitable for the determination of aluminum, iron, nickel, chromium, manganese, lead, zinc, cadmium, cobalt, molybdenum, barium and magnesium in copper indium gallium selenium target. The measurement range is 0.00005% to 0.0020%.
Found what you need?
Document preview — YS/T 1158.3-2016
National Standard of the People's Republic of China
- ICS
- 77.120.30
- Classification
- H 13
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Method summary
- 3 Reagent
Foreword
YS/T 1158 "copper indium gallium selenium target chemical analysis method" is divided into the following three parts.
- Part 1. Determination of gallium content and indium content - Inductively coupled plasma atomic emission spectrometry;
- Part 2. Determination of selenium weight method;
Part 3. Determination of aluminum, iron, nickel, chromium, manganese, lead, zinc, cadmium, cobalt, molybdenum, barium and magnesium - Inductively coupled plasma mass spectrometry.
This section is part 3 of YS/T 1158.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part of the National Nonferrous Metals Standardization Technical Committee (SAC/TC243) proposed and centralized.
This part of the main drafting unit. Guangxi Zhuang Autonomous Region Metallurgical Products Quality Supervision and Inspection Station, Liuzhou 100 ten special advanced materials Limited.
This part participates in the drafting unit. Guangxi Zhuang Autonomous Region Analysis and Testing Research Center, Guangzhou Nonferrous Metals Research Institute, Beijing Mining and Metallurgy Research General Hospital.
1 Scope
YS/T 1158 This section specifies the determination of aluminum, iron, nickel, chromium, manganese, lead, zinc, cadmium, cobalt, molybdenum, barium and magnesium in copper indium gallium selenium target.
This part is suitable for the determination of aluminum, iron, nickel, chromium, manganese, lead, zinc, cadmium, cobalt, molybdenum, barium and magnesium in copper indium gallium selenium target. The measurement range is 0.00005% to 0.0020%.
2 Method summary
The samples were dissolved in nitric acid and hydrochloric acid at low temperature. Scandium and rhodium were used as internal standard. The contents of aluminum, iron, nickel, chromium, Manganese, lead, zinc, cadmium, cobalt, molybdenum, barium, magnesium.
3 Reagent
The water used in the analysis is a grade of water. The containers used in the test were thoroughly soaked in nitric acid solution (1 19) and thoroughly washed with water clean.
3.1 nitric acid (rho = 1.42g/mL). UP grade or equivalent purity.
3.2 Hydrochloric acid (rho = 1.19 g/mL). UP grade or equivalent purity.
3.3 nitric acid (2 1).
3.4 Hydrochloric acid (2 1).
3.5 aluminum standard storage solution. Weigh 1.0000g metal aluminum (wAl >= 99.99%), placed in a 300mL beaker, add 20mL hydrochloric acid (3.4), dropping 1mL ~ 2mL nitric acid (3.3), dissolving at low temperature, removing and cooling to room temperature, moving into 1000mL volumetric flask, adding 80mL hydrochloric acid (3.2), diluted with water to the mark, mix. 1 mL of this solution contains 1 mg of aluminum.
3.6 iron standard storage solution. Weigh 1.0000g metal iron (wFe >= 99.99%), placed in a 300mL beaker, add 40mL nitric acid (3.2), dissolved in low temperature heating, remove and cool to room temperature, into the 1000mL volumetric flask, diluted with water to the mark, mix. This solution 1mL Containing 1 mg of iron.
3.7 nickel standard storage solution. Weigh 1.0000g metal nickel (wNi >= 99.99%), placed in a 300mL beaker, add 20mL nitric acid (3.3), dissolved at low temperature, heated to remove nitrogen oxides, removed and cooled to room temperature, into the 1000mL volumetric flask, add 40mL nitric acid (3.1), diluted with water to the mark, mix well. This solution 1mL containing 1mg nickel.
3.8 chromium standard storage solution. Weigh 3.7349g potassium chromate (wK2CrO4 >= 99.99%, pre-bake at 105 °C 1h), placed in 150mL Beaker, add 20mL water dissolved, add 10mL nitric acid (3.3), into the 1000mL volumetric flask, diluted with water to the mark, mix.
1mL of this solution contains 1mg of chromium.
3.9 Manganese standard storage solution. Weigh 1.0000 g of metal manganese (wMn >= 99.99%), placed in 150mL beaker, add 10mL nitric acid (3.3), dissolved by heating, boiled to remove nitrogen oxides, and cooled. Into the 1000mL volumetric flask, diluted with water to the mark, mix. This solution Liquid 1mL containing 1mg manganese.
3.10 lead standard storage solution. Weigh 1.0000g metal lead (wPb >= 99.99%), placed in 150mL beaker, add 10mL nitric acid
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
How to Download YS/T 1158.3-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 1158.1-2016 — Methods for chemical analysis of copper-indium-gallium-selenide target—Part 1: Determination of gallium, indium contents—Inductively coupled plasma atomic emission spectrometry
YS/T 1158.2-2016 — Methods for chemical analysis of copper-indium-gallium selenide target��Part 2: Determination of selenium content��Gravimetric analysis
YS/T 1115.10-2026 — Chemical analysis methods of copper, lead and zinc ores and tailings - Part 10: Determination of gold, silver, molybdenum, arsenic, tungsten, bismuth, gallium, indium, thallium, selenium, tellurium and germanium contents - Inductively coupled plasma mass spectrometry
Secure payment via Stripe
Payments accepted
YS/T 1158.3-2016